Sponsored Content
Operating Systems HP-UX Need Hardware help on a RP4440 that lost the RTC and does not see both hard drives Post 303029741 by vbe on Thursday 31st of January 2019 01:18:51 PM
Old 01-31-2019
ioscan ?
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Hard drives

Will some one tell me what this means. "warning: ida 0 <slot 6> : command timed out on dev 1/42 blk 4824290 logical unit=0 blocks=5512102, size 2, cmd=0x20." I'm running SCO 505 on a proliant 1600r. Thnank you in advance. (3 Replies)
Discussion started by: franruiz
3 Replies

2. Linux

No Hard Drives Have Been Found

I am using an Acer Aspire 4720Z with two partitions C and D. Windows is installed on C and I decided to install Red Hat Linux 9 in partition D. The two partitions are in NTFS file system. During my installation of the the Linux, a prompt was displayed on screen with the message: "No hard drives... (2 Replies)
Discussion started by: tamcomng
2 Replies

3. Solaris

formating and repartitioning an external hard drives

Version: solaris 10 x86 I just got a western digital external harddrive formated with fat 32. this drive came with some setup files which is meant for windows or mac. I want to reformat and partition this drive into two ( for solaris and windows) such that the setup files will still be there... (2 Replies)
Discussion started by: seyiisq
2 Replies

4. Linux

Is my data lost? Installed Linux, no longer can I access my hard drives.

Here's the story - I installed Linux on my Y drive, and all went well until I tried to boot into XP again. I can't access or install an operating system to my other three hard drives, C, X, and Z. I think that during the install my hard drives were changed to something other then NTFS, but... (4 Replies)
Discussion started by: Ironkey
4 Replies

5. Filesystems, Disks and Memory

Help adding new hard drives

Folks; I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version. Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies

6. Solaris

Reinstall old hard drives

I have a T2000 Sun-Fire server. I have 2 sets of drives in a raid 1. Lets call them Set A and Set B. I had Set A installed and working. I needed a new install so I so build up Set B. After some time I wanted to put Set A back in the server. Now the system will not boot off of Set A. I tried to boot... (7 Replies)
Discussion started by: stu1811
7 Replies

7. Hardware

Hard Drives and MBR

Hello everyone. I have a question which I may know the answer to, I'm just looking for a confirmation. When it comes to the MBR of a hard drive, i've read in multiple sources that it's always located in the first sector of the hard drive. Is the MBR there from the factory? When I buy a new blank... (3 Replies)
Discussion started by: Lost in Cyberia
3 Replies

8. Solaris

Trying to boot Solaris without hard drives in T5220

I have three Sun Oracle Netra T5220s. I am trying to just get the processor information psrinfo or prtdiag -v from the # prompt in single user mode. I am needing to know the commands to get to boot the CD/DVD of the Solaris OS. I am using it via Serial Port Management. Tinkering around I... (4 Replies)
Discussion started by: nerdboy
4 Replies

9. Solaris

Solaris 8 - Accessing Hard Drives

Hi, I have two SCSI Hard Drives in a Sun Solaris 8 server as shown below. I would like to access Disk1 and look at its contents, directory structure and files. How do I change my default directory from Disk 0 to Disk 1 and vice versa? Thank you. (5 Replies)
Discussion started by: ssabet
5 Replies

10. UNIX for Beginners Questions & Answers

Understanding volumes and hard drives

Ok so i thought i was smart but i can tell I need some help. I am playing around with understanding lvm and adding disks to a linux box. I added a disk and then ran what i thought were commands to add this disk to the box but I think I messed up and would like some help. My question is did i... (5 Replies)
Discussion started by: cptkirkh
5 Replies
mptconfig(1M)															     mptconfig(1M)

NAME
mptconfig - configure Ultra320 SCSI controller and A7173A PCI-X Dual Channel Host Bus Adapters SYNOPSIS
<device_file> DESCRIPTION
command provides a mechanism to query or change the SCSI settings of a SCSI bus. The command only operates with Ultra320 SCSI controllers claimed by the MPT driver. Prerequisites: You must be a privileged user in order to run the command. See privileges(5) for more information on privileged users. In addition, some of the options are intended for use by HP support personnel and require detailed knowledge of the Ultra320 SCSI driver or firmware to interpret the output. where device_file specifies the MPT device file associated with one channel of the Ultra320 SCSI controller. The device files are created at boot time or during Online Addition of an adapter. They have the name /dev/mptX, where X is the instance number of the SCSI channel, as reported by for the MPT driver and the ext_bus class of driver. Example: /dev/mpt6. The device file for a specific Ultra320 SCSI adapter can be determined from the output. When the device file parameter is specified without any option, will display command usage information. Options recognizes the following options and parameters. Keyword options are case-sensitive. However, a parameter associated with a keyword is not case-sensitive. where target_id specifies the SCSI ID of a target device on the SCSI bus. Valid values are 0 to 15. The option can be used alone or in combination with or option. When used alone, the command displays the settings and in-use values for the target. When used with the or option, the command sets limits for the rate or width to be used in subsequent communication with the target. where initiator_id specifies the initiator ID of a SCSI interface. Valid values are 0 to 15. This option must be used with caution. See the WARNINGS section for details. where rate specifies the rate at which the Ultra320 controller negotiates with target devices. Valid values are ultra320, ultra160, ultra2, or ultra. When used alone, rate indicates the maximum rate at which the Ultra320 controller will communicate with all devices connected to the SCSI bus. When used with the option, rate indicates the maximum rate at which the Ultra320 controller will communicate with one target. Unless there is a communication problem, the rate of ultra320 should be used for all target devices, since the SCSI protocol automatically adjusts the data transfer rate to compensate for slower devices. where width specifies the data width at which the Ultra320 controller negotiates with target devices. Valid values are wide (16-bit) and narrow (8-bit). When used alone, width indicates the maximum width at which the Ultra320 controller will communicate with all devices connected to the SCSI bus. When used with the option, width indicates the maximum width at which the Ultra320 controller will communicate with one target. Unless there is a communication problem, the width of "wide" should be used for all target devices, since the SCSI pro- tocol automatically adjusts the data transfer width to compensate for 8-bit cables and devices. specifies that default values should be used to configure the SCSI controller. Default values of SCSI parameters are: rate = ultra320, width = wide, and ini- tiator ID = 7. This option must be used with caution. See the WARNINGS section for details. The following table gives an indication of the maximum data transfer rates, given a particular in use rate and data width. In Use Data Data Synchronous Rate Width=16 Width=8 Period nsec Mbytes/s Mbytes/s -------- -------- -------- ----------- Ultra320 320 n/a 6.25 Ultra160 160 n/a 12.5 Ultra2 80 40 25 Ultra 40 20 50 Fast 20 10 100 Async up to 5 Mbytes/s n/a EXAMPLES
These examples show a Ultra320 SCSI controller that is associated with a SCSI bus with instance number 5. Display initiator settings and in-use target parameters Display target parameters and limits at id 4 Set SCSI initiator ID for SCSI controller to 6 Set SCSI bus rate for SCSI controller Set SCSI bus width for SCSI controller Set SCSI initiator id, bus rate and bus width in a single command Set maximum SCSI rate to negotiate with target 8 to ultra2 Restore default SCSI parameters WARNINGS
Setting the initiator ID on a SCSI controller must be done with caution, since duplicate SCSI IDs on a SCSI bus can result in bus hangs, system hangs, and system panics. The command will attempt to verify that no targets are using the specified ID before the change is allowed; however, in the case of multi-initiator (shared bus) configurations, the command cannot detect the presence of other initiators on the SCSI bus. Use the ioscan command on any servers connected to the same SCSI bus to verify that the init_id selected is free before using the option. AUTHOR
was developed by HP. FILES
Executable file. Device files. SEE ALSO
mptutil(1M), ioscan(1M), insf(1M), scsictl(1M), privileges(5) HP Ultra320 SCSI Adapter Support Guide mptconfig(1M)
All times are GMT -4. The time now is 11:38 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.