Sponsored Content
Operating Systems Solaris Solaris link aggregation not working as expected Post 303028364 by solaris_1977 on Saturday 5th of January 2019 01:36:01 PM
Old 01-05-2019
Sorry, my mistake
I have set that now, but no luck
Code:
# ndd -get /dev/igb2 adv_autoneg_cap
1
# ndd -get /dev/igb2  adv_1000fdx_cap
1
# ndd -get /dev/igb2 adv_100fdx_cap
0
# dladm show-aggr
key: 1 (0x0001) policy: L4      address: 3c:d9:2b:f9:20:5e (auto)
           device       address                 speed           duplex  link    state
           bnx1         3c:d9:2b:f9:20:5e         1000  Mbps    full    up      attached
           igb2         f4:ce:46:a7:df:ba         0     Mbps    half    down    standby
key: 2 (0x0002) policy: L4      address: 3c:d9:2b:f9:20:5c (auto)
           device       address                 speed           duplex  link    state
           bnx0         3c:d9:2b:f9:20:5c         1000  Mbps    full    up      attached
           igb3         f4:ce:46:a7:df:bb         1000  Mbps    full    up      attached
#

 

9 More Discussions You Might Find Interesting

1. Solaris

Link Aggregation

Hi there I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question Ive seen multiple websites that say the following Does this also mean that if the... (2 Replies)
Discussion started by: hcclnoodles
2 Replies

2. UNIX for Advanced & Expert Users

Link Aggregation and LACP

Hi there I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question Ive seen multiple websites that say the following Does this also mean that if the... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

3. AIX

Link aggregation with hacmp ?

Hi, I need to setup a hacmp cluster (my first one, we usually use VCS on AIX), but I require more network bandwith than a normal gigabit etherchannel setup can provide, so I am thinking about using linkaggregation - 2 active adapters to one switch and a single backup adapter to another switch... (4 Replies)
Discussion started by: zxmaus
4 Replies

4. Solaris

Link aggregation

Me again :) I'm trying to find a page describing the L2, L3 und L4 modes of dladm. It's nice to read "hashed by ip header", but how should I use that? On the file-server it's ok to have the six interfaces serving six clients each on it's own. But an rsync connection via switch between two... (8 Replies)
Discussion started by: PatrickBaer
8 Replies

5. Solaris

solaris link aggregation problem , once i reboot it is not showing, not able to ping the default gat

Hi All, I am trying to aggregate the NIC's,(igb2 and igb3) (igb0 is used by the physical system and igb1 is used by primary-vsw0) to create the domains on that for faster data transfer, I followed the process for creating the aggregation, dladm create-aggr -d igb2 -d igb3 1 after creating the... (2 Replies)
Discussion started by: buildscm
2 Replies

6. HP-UX

Break Link Aggregation in HP UX.

Hi, I want to Break the Link Aggregation. My aggregation are lan0+lan1 = lan900. Now I want to break this and put the IP in lan0. But i have cluster environment and this is the main database server. So It need to change in cluster script. But I dont know where I have to change it. Please... (1 Reply)
Discussion started by: mkiron
1 Replies

7. Solaris

Link Aggregation without LACP

Hi, I'm not from the Solaris world and some of these things are new to me. Can someone tell me if it is possible to configure link aggregation without using LACP? I am told etherchannel was setup without LACP. (3 Replies)
Discussion started by: techy1
3 Replies

8. Solaris

Link aggregation issues Solaris 10

I have setup link aggregation with 3 interfaces on my solaris 10 system. All looks good but my problem is that the traffic is only going out bge0 and not the other 2 links. bash-4.3# dladm show-aggr -s key:33 ipackets rbytes opackets obytes %ipkts %opkts ... (3 Replies)
Discussion started by: primeaup
3 Replies

9. IP Networking

Link Aggregation

Hi ihave three link of internet and iwant to put one linux front of a firewall that this three linux speard firewall such az load balance and fialover but dont close any port and protocol and only firewall have been internet what way can i use for it ? are there any script and services do that... (0 Replies)
Discussion started by: mnnn
0 Replies
dmfe(7D)							      Devices								  dmfe(7D)

NAME
dmfe - Davicom Fast Ethernet driver for Davicom DM9102A SYNOPSIS
/platform/sun4u/kernel/drv/sparcv9/dmfe DESCRIPTION
The dmfe Ethernet device provides 100Base-TX networking interfaces using the Davicom DM9102A chip, which incorporates its own internal transceiver. The dmfe driver is a multithreaded, loadable, clonable, GLD-based STREAMS driver. Multiple controllers installed within the system are supported by the driver. The dmfe driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. The 100Base-TX standard specifies an auto-negotiation protocol to automatically select the mode and speed of operation. The internal trans- ceiver is capable of performing autonegotiation with the remote-end of the link (link partner) and receives the capabilities of the remote end. It selects the highest common denominator mode of operation based on the priorities. The internal transceiver also supports a forced-mode of operation under which the driver selects the operational mode. APPLICATION PROGRAMMING INTERFACE
The /dev/dmfe cloning character-special device is used to access all Davicom DM9102A devices installed in the system. The dmfe driver is dependent on /kernel/misc/gld, a loadable kernel module that provides the dmfe driver with the DLPI and STREAMS func- tionality required of a LAN driver. See gld(7D) for more details on the primitives supported by the driver. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (ppa). The ppa ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. If the ppa field value does not correspond to a valid device instance number for this system, an error (DL_ERROR_ACK) is returned. The device is initialized on first attach and de-ini- tialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to a DL_INFO_REQ are as follows: o Maximum SDU is 1500 (ETHERMTU - defined in sys/ethernet.h). o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o The sap length value is -2, meaning the physical address component is followed immediately by a 2-byte sap component within the DLSAP address. o The broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular Service Access Point (SAP) with the stream. CONFIGURATION
By default, the dmfe driver performs auto-negotiation to select the speed and mode of the link. Link speed and mode can be 100 Mbps (full or half-duplex) or 10 Mbps (full or half-duplex) as described in the 100Base-TX standard. The auto-negotiation protocol automatically selects speed mode (either 100 Mbps or 10 Mbps) and operation mode (either full-duplex or half- duplex) as the highest common denominator supported by both link partners. Because the dmfe device supports all modes, this effectively selects the highest-throughput mode supported by the other device. Alternatively, you can explicitly specify the link parameters by adding entries to the dmfe driver configuration file (/platform/sun4u/ker- nel/drv/dmfe.conf). You can set the speed parameter to 10 or 100 to force dmfe devices to operate at the specified speed. Additionally, you can set the full-duplex parameter to 0 or 1 to disable or force full-duplex operation, respectively. Note that specifying either "speed" or "full-duplex" explicitly disables auto-negotiation. To enable the driver to determine the appropri- ate setting for each parameter, you should always set both parameters. If it is necessary to force either speed or duplex setting (for example, because the dmfe device is connected to an ancient device or hub that does not support auto-negotiation), both parameters should be explicitly specified to match the requirements of the external device. FILES
/dev/dmfe Character special device /platform/sun4u/kernel/drv/dmfe.conf dmfe configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5), gld(7D), dlpi(7P), streamio(7I) Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.10 23 July 2003 dmfe(7D)
All times are GMT -4. The time now is 05:17 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy