Operating Systems Solaris Solaris link aggregation not working as expected Post 303028356 by MadeInGermany on Saturday 5th of January 2019 07:00:31 AM
Old 01-05-2019
adv_100fdx_cap?
I think you want adv_1000fdx_cap
Also ensure that adv_autoneg_cap is set.
This User Gave Thanks to MadeInGermany For This Post:
 

9 More Discussions You Might Find Interesting

1. Solaris

Link Aggregation

Hi there I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question Ive seen multiple websites that say the following Does this also mean that if the... (2 Replies)
Discussion started by: hcclnoodles
2 Replies

2. UNIX for Advanced & Expert Users

Link Aggregation and LACP

Hi there I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question Ive seen multiple websites that say the following Does this also mean that if the... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

3. AIX

Link aggregation with hacmp ?

Hi, I need to setup a hacmp cluster (my first one, we usually use VCS on AIX), but I require more network bandwith than a normal gigabit etherchannel setup can provide, so I am thinking about using linkaggregation - 2 active adapters to one switch and a single backup adapter to another switch... (4 Replies)
Discussion started by: zxmaus
4 Replies

4. Solaris

Link aggregation

Me again :) I'm trying to find a page describing the L2, L3 und L4 modes of dladm. It's nice to read "hashed by ip header", but how should I use that? On the file-server it's ok to have the six interfaces serving six clients each on it's own. But an rsync connection via switch between two... (8 Replies)
Discussion started by: PatrickBaer
8 Replies

5. Solaris

solaris link aggregation problem , once i reboot it is not showing, not able to ping the default gat

Hi All, I am trying to aggregate the NIC's,(igb2 and igb3) (igb0 is used by the physical system and igb1 is used by primary-vsw0) to create the domains on that for faster data transfer, I followed the process for creating the aggregation, dladm create-aggr -d igb2 -d igb3 1 after creating the... (2 Replies)
Discussion started by: buildscm
2 Replies

6. HP-UX

Break Link Aggregation in HP UX.

Hi, I want to Break the Link Aggregation. My aggregation are lan0+lan1 = lan900. Now I want to break this and put the IP in lan0. But i have cluster environment and this is the main database server. So It need to change in cluster script. But I dont know where I have to change it. Please... (1 Reply)
Discussion started by: mkiron
1 Replies

7. Solaris

Link Aggregation without LACP

Hi, I'm not from the Solaris world and some of these things are new to me. Can someone tell me if it is possible to configure link aggregation without using LACP? I am told etherchannel was setup without LACP. (3 Replies)
Discussion started by: techy1
3 Replies

8. Solaris

Link aggregation issues Solaris 10

I have setup link aggregation with 3 interfaces on my solaris 10 system. All looks good but my problem is that the traffic is only going out bge0 and not the other 2 links. bash-4.3# dladm show-aggr -s key:33 ipackets rbytes opackets obytes %ipkts %opkts ... (3 Replies)
Discussion started by: primeaup
3 Replies

9. IP Networking

Link Aggregation

Hi ihave three link of internet and iwant to put one linux front of a firewall that this three linux speard firewall such az load balance and fialover but dont close any port and protocol and only firewall have been internet what way can i use for it ? are there any script and services do that... (0 Replies)
Discussion started by: mnnn
0 Replies
afe(7D) 							      Devices								   afe(7D)

NAME
afe - ADMtek Fast Ethernet device driver SYNOPSIS
/dev/afe DESCRIPTION
The afe driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on ADMtek (now Infineon) Centaur and Comet Fast Ethernet controllers. APPLICATION PROGRAMMING INTERFACE
The afe driver can be used as either a "style 1" or a "style 2" Data Link Service Provider. Physical points of attachment (PPAs) are inter- preted as the instance number of the afe controller as assigned by the Solaris operating environment. The relevant fields returned as part of a DL_INFO_ACK response are: o Maximum SDU is 1500. o Minimum SDU is 0. o The dlsap address length is 8. o MAC type is DL_ETHER. o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP. o Service mode is DL_CLDLS. o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff). If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are bound to SAP zero (the 802.3 SAP). PROPERTIES
The following properties may be configured using either ndd(1M) or the afe.conf configuration file as described by driver.conf(4): adv_autoneg_cap Enables (default) or disables IEEE 802.3u auto-negotiation of link speed and duplex settings. If enabled, the device negotiates among the supported (and configured, see below) link options with the link partner. If disabled, at least one of the link options below must be specified. The driver selects the first enabled link option according to the IEEE 802.3u specified preferences. adv_100T4_cap Enables the 100 BaseT4 link option. (Note that most hardware does not support this unusual link style. Also, this uses two pairs of wires for data, rather than one.) adv_100fdx_cap Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern equipment supports this mode.) adv_100hdx_cap Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.) adv_10fdx_cap Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps switch.) adv_10hdx_cap Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when the link partner is a 10 Mbps hub or is an older network card.) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SPARC, x86 | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ FILES
/dev/afe Special character device. /kernel/drv/afe 32-bit driver binary (x86). /kernel/drv/amd64/afe 64-bit driver binary (x86). /kernel/drv/sparcv9/afe 64-bit driver binary (SPARC). /kernel/drv/afe.conf Configuration file. SEE ALSO
ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P) IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002 SunOS 5.11 1 Apr 2007 afe(7D)
All times are GMT -4. The time now is 03:13 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy