12-03-2018
Hi Vext01,
As you've had the machine in bits and have replaced the guts, I'm going to stick my neck out and suggest that the connections should be good as they should all have been re-seated during component changes. I'd maybe tempted to swap the PSU if you have one, but the maintenance indicator would generally be on if it was faulty.
It might be that just pulling and re-seating the power supply would be enough.
I'm kind of running out of steam on this, you've changed the MOBO and the CPU's. The fault has remained pretty consistent, from the environmentals it doesn't seem to be power related. I'ts unlikely that this will make any difference, but can you capture the ALOM config and then run a sc> resetsc you'll have to go through the setting up the ALOM again (Although you should just need to change the password as the rest should work).
Additionally something has just come to the fore, didn't happen to me - it was an engineer that I worked with. He had a fault on a v210 or it may have been a v240 - where he replaced the Mother Board and couldn't get to the ok prompt.
Turned out that he'd mixed the matched pairs of memory and that causes the OBP not to start, it didn't supply an error message either - I've been in touch with him and although the Dimm's were the same speed - they had different manufacturers and that was enough.
Regards
Gull04
Last edited by gull04; 12-03-2018 at 09:29 AM..
Reason: More Info
7 More Discussions You Might Find Interesting
1. Solaris
hi all, how can install a display card on a sun fire v210.
regards. marcel (2 Replies)
Discussion started by: marcelious
2 Replies
2. Solaris
I recently acquired a server for home use. Currently, I'm running a V210. I was wondering of a way to basically swap hard drives into the V440.
I would like to avoid reinstall on the V440 for many reasons.
Currently on the V440, when I try to boot up it forces itself into System Maintenance... (1 Reply)
Discussion started by: adelsin
1 Replies
3. Solaris
I'm currently trying to move a perfectly find harddrive from a V210 to a V440. From what I can tell, the disk labeling a bit different, (V210 is c1t0d0 and V440 is c0t0d0). My question is, what all do I have to change to get the V440 to boot off of this with very little complications. Right now, it... (21 Replies)
Discussion started by: adelsin
21 Replies
4. Solaris
Sun Fire V210, No Keyboard
Copyright 1998-2003 Sun Microsystems, Inc. All rights reserved.
OpenBoot 4.13.2, 4096 MB memory installed, Serial #61203679.
Ethernet address 0:3:ba:a5:e4:df, Host ID: 83a5e4df.
Boot device: net File and args:
100 Mbps FDX Link up
Timeout waiting for... (5 Replies)
Discussion started by: Mrudhul
5 Replies
5. Solaris
I have bought from eBay a second hand Sun Fire V210 server and I'm really stumped at the lack of complete instructions on how to connect to it.
I don't have a Windows machine, I've only got Ubuntu and OS X computers. None of them have an old RS-232 port on them either.
In saying that, I have... (12 Replies)
Discussion started by: danijeljames
12 Replies
6. UNIX for Dummies Questions & Answers
Purchased a Sun Surefire V210 Server off eBay. Unable to Access the Terminal Mode via the Terminal MGT. Using Windows 7 home, and downloaded the ConEmu.
The ConEmu brings up a Command line on the PC, and that's it.
Being new to all this, I was expecting a Login prompt to pop up. Read the... (22 Replies)
Discussion started by: screenprintr
22 Replies
7. Solaris
Hey,
I have a V210 with a failed CPU fan.
The temperature is currently at 84C and I've been asked to wait a few weeks before replacing as its a production system and it cant be shut down yet.
Is it too hot? Do I risk killing the CPU at this temp?
Its been like this for a few weeks now... (5 Replies)
Discussion started by: magarvo
5 Replies
LEARN ABOUT DEBIAN
fence_alom
FENCE_AGENT(8) System Manager's Manual FENCE_AGENT(8)
NAME
fence_alom - Fence agent for Sun ALOM
DESCRIPTION
fence_alom is an I/O Fencing agent which can be used with ALOM connected machines.
fence_alom accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent.
fence_alom can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.
Vendor URL: http://www.sun.com
PARAMETERS
-o, --action=<action>
Fencing Action (Default Value: reboot)
-a, --ip=<ip>
IP Address or Hostname This parameter is always required.
-l, --username=<name>
Login Name This parameter is always required.
-p, --password=<password>
Login password or passphrase
-S, --password-script=<script>
Script to retrieve password
-x, --ssh
SSH connection (Default Value: true)
-k, --identity-file=<filename>
Identity file for ssh
-4, --inet4-only
Forces agent to use IPv4 addresses only
-6, --inet6-only
Forces agent to use IPv6 addresses only
-u, --ipport=<port>
TCP port to use for connection with device
-v, --verbose
Verbose mode
-D, --debug-file=<debugfile>
Write debug information to given file
-V, --version
Display version information and exit
-h, --help
Display help and exit
--power-timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
--shell-timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
--login-timeout
Wait X seconds for cmd prompt after login (Default Value: 5)
--power-wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
--delay
Wait X seconds before fencing is started (Default Value: 0)
--retry-on
Count of attempts to retry power on (Default Value: 1)
ACTIONS
on Power on machine.
off Power off machine.
reboot Reboot machine.
status This returns the status of the plug/virtual machine.
list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
monitor
Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more).
metadata
The operational behavior of this is not known.
STDIN PARAMETERS
action Fencing Action (Default Value: reboot)
ipaddr IP Address or Hostname This parameter is always required.
login Login Name This parameter is always required.
passwd Login password or passphrase
passwd_script
Script to retrieve password
secure SSH connection (Default Value: true)
identity_file
Identity file for ssh
inet4_only
Forces agent to use IPv4 addresses only
inet6_only
Forces agent to use IPv6 addresses only
ipport TCP port to use for connection with device
verbose
Verbose mode
debug Write debug information to given file
version
Display version information and exit
help Display help and exit
power_timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
shell_timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
login_timeout
Wait X seconds for cmd prompt after login (Default Value: 5)
power_wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
delay Wait X seconds before fencing is started (Default Value: 0)
retry_on
Count of attempts to retry power on (Default Value: 1)
fence_alom (Fence Agent) 2009-10-20 FENCE_AGENT(8)