Operating Systems Solaris Help with Reviving a NETRA240 Pls? Post 303026402 by ozsavran on Tuesday 27th of November 2018 06:44:34 AM
Old 11-27-2018
Is it Battery or Is it Jumpers?

Dear Mr. Hicks,

Thanks again for your smart electronics probing from afar. Smilie Yes you are right, the coin battery is most probably dead. I bought this from a government surplus liquadator from Ankara, it should have been sitting somewhere for long. Its a 2006 model, I think. Battery must also be 12 years old. Seller did promise to change any parts if necessary. That we have in pocket, but he is just 400 miles from here. Smilie The battery holder seems a little delicate, I did try to take that out when it first arrived. I will have to take that out somehow now that it is relevant.

When I first entered SC, yes there was no password. But I can set a password, after that it does allow me to use the "poweron". That command again starts the main air blower inside. But then "poweroff" does respond with a "power is already off". If changing that battery doesn't solve the issue, we can try loading an OS through the 2 USB slots hopefully.

Another idea is to check the jumpers on the motherboard, IMHO. I found the table for it in the manuals. I will photo their current setup for you to inspect, in any case.

BTW, just received the "High Noon" book about McNealy from your country, the good old UK. A University of Derby discard in perfect condition. I just love reading self-promotion volumes of silicon valley boys paid for their personal advertisements. Smilie Just gobbled up Dr. David Yen's book, named "Under the Sun: My 20 years in Sun Micro.." the previous night in one long sitting. That was heady. This old clunky machine stimulates the unsatisfied electronics engineer in me, whether works or not. My favorite classes were Digital Design and Computer Architecture, both using wonderful books of Morris Mano (photocopies of course) when I was in Istanbul Tech. Baah, the good ole days man... Smilie

Last edited by ozsavran; 11-27-2018 at 08:09 AM..
This User Gave Thanks to ozsavran For This Post:
 

10 More Discussions You Might Find Interesting

1. Linux

pls help me

we hv a big enviroment networked. we use squid proxy. access allowed by src address previously. we have win2000 network with ads. my requirement is the proxy should allow domain users only for access. how can i map my windows userdatabase with squid is there any thing specific which has 2 b... (1 Reply)
Discussion started by: sriram.s
1 Replies

2. UNIX for Dummies Questions & Answers

Need help pls

Hi, I'm a newbie. I need help on my first assignment in UNIX. 1. How do I determine the number of non-empty directories? I was told to create a variable ARCHIVE, which points to the directory that contains the archive of the messages. But I'm so dumb and I don't even know how to do this. 2. In... (1 Reply)
Discussion started by: hygsg
1 Replies

3. UNIX for Dummies Questions & Answers

Pls Help

Hi every one I have got very very bad Email, My question is: How can I get all information about that f*** Email, I do mean IP,reall name, Adress, user name, password etc... I wonder if there is any program or website that I can see that email, help me please When I used windows Xp(old... (2 Replies)
Discussion started by: Cano
2 Replies

4. UNIX for Dummies Questions & Answers

Help pls!

Hi... Why should I press F1 to start windows?! I have Xp in my computer... thx 4 help Cano (1 Reply)
Discussion started by: Cano
1 Replies

5. Shell Programming and Scripting

pls help

I have a list of variables: ss1, ss5, ss6, ss8, st2 etc. (these values are not fixed, configurable). Now, I have assigned ss5=”test”. And I want to search in the list for the string “test” to know which variable is having the value “test”. Can u pls tell me how to do this? (10 Replies)
Discussion started by: kanchan_cp
10 Replies

6. Shell Programming and Scripting

pls help

Hi, I need your help guys. I have two data files, namely 101.amberized.pdb & 101.pdb . Now I want to replace the whole 3rd column of 101.amberized.pdb with the 3rd column of 101.pdb file. How do I do it in shell? Thanks in advance Parimal (11 Replies)
Discussion started by: chuchu
11 Replies

7. Shell Programming and Scripting

Pls Pls do help me

When i run this command, everything is ok. The file can be email and attached but soon after i download the file, the file cant be read. It's seem corrupted. Totally cant be read although i'm using context or wordfile. Original file generated at ek_bkup/alert/tbspace_datafile.log is OK..... ... (7 Replies)
Discussion started by: adzuanamir
7 Replies

8. UNIX for Dummies Questions & Answers

HELP PLs

I have this code: #!/bin/sh awk 'BEGIN NR == 2 repl = "PHI" $4 = repl print $0 'dryloop.txt and this code: #!/bin/sh sed -e '1s/\|$/\|COMID\|/g' -e 's/^087.*$/&PHI\|g' hl.dsldryloop > textdry.txt My code won't work. I want to change the COMID of lines starting with 087 . this is my... (15 Replies)
Discussion started by: arkhei
15 Replies

9. Homework & Coursework Questions

Help pls

How to find the ten most common words in a file (1 Reply)
Discussion started by: jass
1 Replies

10. Solaris

NETRA240 in HLR CDMA Wireless Exchange... help is apreciated

Greetings, I hope my post finds you all OK, I have a Netra240 server in an HLR inside a wireless CDMA Exchange, it works as a Hard Disk Unit (HDU) as shown in Local Management Terminal (LMT) as show in the picture 1 attached. The power went down because of a power failure in main UPS, when... (2 Replies)
Discussion started by: Sharista
2 Replies
BESTUPS(8)							    NUT Manual								BESTUPS(8)

NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option. Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not known. This driver does not support some older Best/SOLA units. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): nombattvolt=num Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports battery.charge values just below 100% even when it's completely charged. If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good battery. The author's Best Fortress 750 uses nombattvolt=27.4. battvoltmult=num Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage. For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this particular case you can set battvoltmult = 12 in ups.conf(8) to fix this. ID=string Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F AAA is the three-character identification for the UPS model. BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9. CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC. DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC. EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts DC and a decimal point is present. FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for 700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F. Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0". BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver. Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes back on-line, so you can't tell when it is really recharged. Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use nombattvolt= in ups.conf(8) to fix this. AUTHOR
Russell Kroll, Jason White SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 BESTUPS(8)
All times are GMT -4. The time now is 09:11 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy