Sponsored Content
Operating Systems Solaris Solaris 11.4.2.3.0 - dladm link names mapping Post 303025256 by javanoob on Monday 29th of October 2018 01:42:00 PM
Old 10-29-2018
Solaris 11.4.2.3.0 - dladm link names mapping

Hi all,


I have never wondered where is the mapping of the link names to physical device path display under

Code:
dladm show-phys

until today.


fmadm list reported nic port failure and i am trying to mapped it to the correct linkname in dladm show-link / dladm show-phys to see if the link is actually up and running or down.


I remember it used to be under /etc/dladm/ , so i went to list it


Code:
ls -la /etc/dladm/
total 29
drwxr-xr-x   2 netadm   netadm         6 Oct 29 17:02 .
drwxr-xr-x  88 root     sys          181 Oct 29 20:56 ..
-rw-r--r--   1 netcfg   netadm      1296 Jun 14 16:06 datalink-Automatic.conf.obsolete
-rw-r--r--   1 netcfg   netadm       512 Sep  7 02:38 datalink-DefaultFixed.conf.obsolete
-rw-r--r--   1 netcfg   netadm      1564 Oct 27 14:30 datalink.conf.obsolete
-rw-rw----   1 dladm    netadm       186 Oct 27 14:08 secobj.conf

Everything has a .obsolete tag behind and i remember that i have recently updated to 11.4
So i went back to mount my old 11.3 boot environment and realize those files in the same path doesn't have a .obsolete behind.


So long story short,

a) do you guys on 11.4 have these .obsolete files as well ?

b) if these files are obsolete, where does 11.4 store these link-to-device information now ?


SmilieSmilieSmilie


Regards,
Noob

Last edited by javanoob; 10-29-2018 at 02:43 PM.. Reason: clarity
 

9 More Discussions You Might Find Interesting

1. Solaris

[help] about symbolic link solaris 8

hi experts, i had create wrong symbolic link on my server use this ln -s /opt/EBS /export/home/EBS, cause i had create an EBS directory on /export/home/EBS/ so the command ln create EBS directory on /export/home/EBS/EBS/.... how to remove the EBS that had created by ln command ? thank you... (1 Reply)
Discussion started by: bucci
1 Replies

2. Solaris

dladm use

Thanks to DukeNuke for the suggestion of dladm before. I was able to upgrade my machine to Solaris 10. I am checking out the sue of dladm, but I am a bit confused. In order to team 2 NIC ports together on my qud ethernet card do I just do this: dladm create aggr -d ce0 -d ce1 key Do I need to... (1 Reply)
Discussion started by: hshapiro
1 Replies

3. UNIX for Advanced & Expert Users

Solaris to HP-UX 11i v2 kernel parameter mapping

Can anyone reference me where I can find info or if someone knows the mapping of Solaris kernel parameters to HP-UX 11i v2 O/S on Integrity server? Your response would be greatly appreciated. Thanks. -Lou :) (1 Reply)
Discussion started by: nylou97
1 Replies

4. Solaris

Link for solaris on x86

Hi All, Can any body guide me towards the x86 link? I need to understand the disk slice and booting sequences in x86 as I have to give my SA1. Please help. (4 Replies)
Discussion started by: kumarmani
4 Replies

5. Solaris

remove interface from dladm

Greetings how can i remove an interface from dladm? i want to remove ce3 and ce4 which are not even plumbed but still shown in dladm output :( dladm show-dev ce0 link: unknown speed: 1000 Mbps duplex: full ce1 link: unknown speed: 1000 Mbps duplex:... (3 Replies)
Discussion started by: kashif_islam
3 Replies

6. Solaris

ifconfig -a vs dladm show-dev and IP ?

Can anyone please explain what does these means ? # dladm show-dev nxge0 link: up speed: 1000 Mbps duplex: full nxge1 link: up speed: 1000 Mbps duplex: full e1000g0 link: up speed: 1000 Mbps duplex: full e1000g1 ... (6 Replies)
Discussion started by: dehetoxic
6 Replies

7. Solaris

[beginner] dladm create-bridge

hello everyone, I'm a new user and unix-beginner. I've just installer solaris 11 on my home server, disabled some services, created a fallback BE, enabled speedstep, etc and now I'm trying to create some zones. I'd like to have an exclusive ip zone and, as far as I know, I sould assignate it... (12 Replies)
Discussion started by: kimj
12 Replies

8. Shell Programming and Scripting

Creating unique mapping from multiple mapping

Hello, I do not know if this is the right title to use. I have a large dictionary database which has the following structure: where a b c d e are in English and p q r s t are in a target language., the two separated by the delimiter =. What I am looking for is a perl script which will take... (5 Replies)
Discussion started by: gimley
5 Replies

9. UNIX for Advanced & Expert Users

Mapping Oracle SGA memory into physical files in Solaris.

Is there a way by which we could map Oracle SGA memory into physical files in solaris. We could find these physical files in /dev/shm/ folder in linux environment but they are missing in solaris. (1 Reply)
Discussion started by: arjun_chauhan
1 Replies
igb(7D) 							      Devices								   igb(7D)

NAME
igb - Intel 82575 1Gb PCI Express NIC Driver SYNOPSIS
/dev/igb* DESCRIPTION
The igb Gigabit Ethernet driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface, dlpi(7P), on Intel 82575 Gigabit Ethernet controllers. The igb driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. The igb driver and hardware support auto-negotiation, a protocol specified by the 1000 Base-T standard. Auto-negotiation allows each device to advertise its capabilities and discover those of its peer (link partner). The highest common denominator supported by both link partners is automatically selected, yielding the greatest available throughput, while requiring no manual configuration. The igb driver also allows you to configure the advertised capabilities to less than the maximum (where the full speed of the interface is not required), or to force a specific mode of operation, irrespective of the link partner's advertised capabilities. APPLICATION PROGRAMMING INTERFACE
The cloning character-special device, /dev/igb, is used to access all Intel 82575 Gigabit devices installed within the system. The igb driver is managed by the dladm(1M) command line utility, which allows VLANs to be defined on top of igb instances and for igb instances to be aggregated. See dladm(1M) for more details. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (PPA). The PPA ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. The driver returns an error (DL_ERROR_ACK) if the PPA field value does not correspond to a valid device instance number for the system. The device is initialized on first attach and de- initialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to your DL_INFO_REQ are: o Maximum SDU is 9000. o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o SAP (Service Access Point) length value is -2, meaning the physical address component is followed immediately by a 2-byte SAP component within the DLSAP address. o Broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular SAP with the stream. CONFIGURATION
By default, the igb driver performs auto-negotiation to select the link speed and mode. Link speed and mode can be any one of the follow- ing, (as described in the IEEE803.2 standard): 1000 Mbps, full-duplex. 100 Mbps, full-duplex. 100 Mbps, half-duplex. 10 Mbps, full-duplex. 10 Mbps, half-duplex. The auto-negotiation protocol automatically selects speed (1000 Mbps, 100 Mbps, or 10 Mbps) and operation mode (full-duplex or half-duplex) as the highest common denominator supported by both link partners. Alternatively, you can set the capabilities advertised by the igb device using ndd(1M). The driver supports a number of parameters whose names begin with adv_ (see below). Each of these parameters contains a boolean value that determines if the device advertises that mode of operation. For example, the adv_1000fdx_cap parameter indicates if 1000M full duplex is advertised to link partner. The adv_autoneg cap parameter controls whether auto-negotiation is performed. If adv_autoneg_cap is set to 0, the driver forces the mode of operation selected by the first non-zero parameter in priority order as shown below: (highest priority/greatest throughput) adv_1000fdx_cap 1000Mbps full duplex adv_100fdx_cap 100Mpbs full duplex adv_100hdx_cap 100Mbps half duplex adv_10fdx_cap 10Mpbs full duplex adv_10hdx_cap 10Mpbs half duplex (lowest priority/least throughput) All capabilities default to enabled. Note that changing any capability parameter causes the link to go down while the link partners renego- tiate the link speed/duplex using the newly changed capabilities. FILES
/dev/igb* Special character device. /kernel/drv/igb 32-bit device driver (x86). /kernel/drv/amd64/igb 64-bit device driver (x86). /kernel/drv/sparcv9/igb 64-bit device driver (SPARC). /kernel/drv/igb.conf Configuration file. SEE ALSO
dladm(1M), ndd(1M), netstat(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P), Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.11 20 Jul 2007 igb(7D)
All times are GMT -4. The time now is 03:43 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy