Hello,
I have a V880 and a 420 running Solaris 9. Each box has more than one NIC card. I'd like to know how to configure the network on the two boxes so that I can directly connect the NIC cards. Meaning, I don't want a switch or router between the two. I just want to run a CAT5 cable to each... (3 Replies)
Hi,
I have a script in which i'm using ndm connect direct to fetch data from the client server..syntax i'm using is
./con_using_connectdirect /load/nctrl nctrl $xhost
where con_using_connectdirect is the script which establishes connection
load/nctrl is the path from where data... (4 Replies)
Hi,
I am configuring Connect direct on Solaries 6.0,
but whenever i am giving the below command
cdpmgr -i /export/app/cdunix/ndm/cfg/khello/initparm.cfg
i am getting the message
Component <cdpmgr ndmcmgr ndmsmgr ndmumgr cdstatm> permissions are not set.
Please follow instructions in the... (3 Replies)
Hi to all,
I've installed IBM Connect:Direct 4.1.00 on Red Hat Enterprise Linux Server release 5.5, but when I try to execute the "direct cli", I obtain the following error:
$ ./direct
***********************************************************
* ... (2 Replies)
Hello all,
I have a requirement to transfer files to mainframe usinf NDM connect:direct. So can anybody provide me a sample shell script on how to call a connect;direct script by providing filename as a parameter please?
Thanks,
Ajay (0 Replies)
I want to connect direct a xml file and a excel file each separately from unix system to another unix system.The size of the xml file and excel file may vary each time.
Below is the possible connect direct script to transfer the files.Please check if it is correct?
Also does DCB parameter... (4 Replies)
I am transfering a file using connect direct from Linux to Mainframe.
Its a point to point transfer but its failing with below error:
**** Error from CONNECT:Direct API - ndmapi_recvresp_c error
Can we do PTP transfers?
code tags for code, please. (1 Reply)
Hi..
We are using connect direct to transfer the files between servers. The CD scripts run on HP UX.
Below is the code using ndmcli.
ndmcli -x << EOJ
submit maxdelay=0 proc1 process snode=$3
step1 ... (1 Reply)
Hello,
We have an Power8 System (S822) and a IBM StorWize v3700 SAN.
The OS is AIX 7.1.
With this hardware from what I read I need to download/install special SDDPCM drivers, so I did (SDDPCM VERSION 2.6.6.0 (devices.sddpcm.71.rte).
I carved my volumes in the StorWize and presented to... (3 Replies)
Greetings Experts,
I am working for a bank client and have a question on connect-direct and SFTP.
We are using Linux RedHat servers. We use connect-direct to transfer (NDM) files from one server to another server. At times, we manually transfer the files using SFTP from one server to another... (2 Replies)
Discussion started by: chill3chee
2 Replies
LEARN ABOUT CENTOS
hwloc_mx_board_get_device_cpuset
Myrinet Express-Specific Functions(3) Hardware Locality (hwloc) Myrinet Express-Specific Functions(3)NAME
Myrinet Express-Specific Functions -
Functions
static inline int hwloc_mx_board_get_device_cpuset (hwloc_topology_t topology, unsigned id, hwloc_cpuset_t set)
static inline int hwloc_mx_endpoint_get_device_cpuset (hwloc_topology_t topology, mx_endpoint_t endpoint, hwloc_cpuset_t set)
Detailed DescriptionFunction Documentation
static inline int hwloc_mx_board_get_device_cpuset (hwloc_topology_ttopology, unsignedid, hwloc_cpuset_tset) [static]
Get the CPU set of logical processors that are physically close the MX board id. Return the CPU set describing the locality of the Myrinet
Express board whose index is id.
Topology topology and device id must match the local machine. I/O devices detection is not needed in the topology.
The function only returns the locality of the device. No additional information about the device is available.
static inline int hwloc_mx_endpoint_get_device_cpuset (hwloc_topology_ttopology, mx_endpoint_tendpoint, hwloc_cpuset_tset) [static]
Get the CPU set of logical processors that are physically close the MX endpoint endpoint. Return the CPU set describing the locality of the
Myrinet Express board that runs the MX endpoint endpoint.
Topology topology and device id must match the local machine. I/O devices detection is not needed in the topology.
The function only returns the locality of the endpoint. No additional information about the endpoint or device is available.
Author
Generated automatically by Doxygen for Hardware Locality (hwloc) from the source code.
Version 1.7 Sun Apr 7 2013 Myrinet Express-Specific Functions(3)