08-03-2018
Hello @jgt . Thanks for the response . Fair answer - i wish you were my boss :-)
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
can someone tell me a good site to go to in order to learn this. please do not recommen nay books because i dont have interest in that. if you know of any good sites with good straight forward explanation on how to split loads on machines that has excessive loading, please let me know
Also,... (1 Reply)
Discussion started by: TRUEST
1 Replies
2. Filesystems, Disks and Memory
Hi all,
long time ago I posted something, but now, it is needed again :(
Currently, I am handling with a big NFS Server for more than 200 clients, this sever has to work with 256 NFSDs. Because of this huge amount of NFSDs, there are thousands of small write accesses down to the disk and... (3 Replies)
Discussion started by: malcom
3 Replies
3. UNIX for Dummies Questions & Answers
Hi to all,
I'm interested in finding an introduction about Performance Tuning under Unix (or Linux); can somebody please point me in the right direction?
Best regards (1 Reply)
Discussion started by: domyalex
1 Replies
4. Shell Programming and Scripting
Sorry,
This is out of scope of this group.But I require the clarification pretty urgently.
My Oracle database is parallely enabled.
Still,in a particular table queries do not work "parallely" always.
How is this? (9 Replies)
Discussion started by: kthri
9 Replies
5. Shell Programming and Scripting
Hi All,
In last one week, i have posted many questions in this portal. At last i am succeeded to make my 1st unix script.
following are 2 points where my script is taking tooooo long.
1. Print the total number of records excluding header & footer. I have found that awk 'END{print NR -... (2 Replies)
Discussion started by: Amit.Sagpariya
2 Replies
6. AIX
Dear friends. can anybody suggest me what to be considered in order to achieve maximum performance of AIX on which DB2 will be installed
Thanks is advance :) (1 Reply)
Discussion started by: Vit0_Corleone
1 Replies
7. Solaris
Dear all,
I have a Local zone , where users feel that performance is not good.
Is it wise to collect the inputs from the local zone rather than taking from the global zone.
And also Can I tune from Global zone , so that it will reflect in local zone.
Rgds
rj (2 Replies)
Discussion started by: jegaraman
2 Replies
8. Solaris
Hello Forum,
Well I am fairly new to this Solaris os thing. One thing I would like to check for system health and performance.
I know the codes like
prstat,vmstat,sar,iostat,netstat,prtdiag -v,
What else does a want to be sys admin have to look for when checking a solaris box?
I know... (3 Replies)
Discussion started by: br1an
3 Replies
9. AIX
I have a IBM Power9 server coupled with a NVMe StorWize V7000 GEN3 storage, doing some benchmarks and noticing that single thread I/O (80% Read / 20% Write, common OLTP I/O profile) seems slow.
./xdisk -R0 -r80 -b 8k -M 1 -f /usr1/testing -t60 -OD -V
BS Proc AIO read% IO Flag IO/s ... (8 Replies)
Discussion started by: c3rb3rus
8 Replies
LEARN ABOUT REDHAT
elvtune
ELVTUNE(8) System Manager's Manual ELVTUNE(8)
NAME
elvtune - I/O elevator tuner
SYNOPSIS
elvtune [ -r r_lat ] [ -w w_lat ] [ -b b_max ] /dev/blkdev1 [ /dev/blkdev2 ... ]
elvtune -h
elvtune -v
DESCRIPTION
elvtune allows to tune the I/O elevator per blockdevice queue basis. The tuning can be safely done at runtime. Tuning the elevator means
being able to change disk performance and interactiveness. In the output of elvtune the address of the queue tuned will be shown and it can
be considered as a queue ID. For example multiple partitions in the same harddisk will share the same queue and so tuning one partition
will be like tuning the whole HD.
OPTIONS
-r r_lat
set the max latency that the I/O scheduler will provide on each read.
-w w_lat
set the max latency that the I/O scheduler will provide on each write.
-b b_max
max coalescing factor allowed on writes when there are reads pending in the queue.
-h help.
-v version.
NOTE
Actually the only fields tunable are those relative to the IO scheduler. It's not possible to select a one-way or two-way elevator yet.
For logical blockdevices like LVM the tuning has to be done on the physical devices. Tuning the queue of the LVM logical device is useless.
RETURN VALUE
0 on success and 1 on failure.
HISTORY
Ioctls for tuning elevator behaviour were added in Linux 2.3.99-pre1.
AUTHORS
Andrea Arcangeli <andrea@suse.de> SuSE
Version 1.0 14 March 2000 ELVTUNE(8)