Sponsored Content
Full Discussion: M5000 won't power up
Special Forums Hardware M5000 won't power up Post 303018942 by DukeNuke2 on Tuesday 19th of June 2018 02:09:58 PM
Old 06-19-2018
Quote:
Originally Posted by goya
no support since its older. just a company that swaps parts. I did try the power on each domain and same result , did no reset fault, what command does that? I will try and find it.
From the XSCF use the command version -c xcp and send the output. Depending on the version you might not be able to reset the error...
This User Gave Thanks to DukeNuke2 For This Post:
 

9 More Discussions You Might Find Interesting

1. AIX

won't mount /usr...won't boot fully

Hello: NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies

2. Solaris

M5000 Question

Hi, I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies

3. Solaris

M5000 Question

Hi i 've a M5000 running 2 domains in my Lab with following hardconf SPARC Enterprise M5000; Memory_Size:128 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies

4. Solaris

Unable to start SunVTS on M5000

Please advise. Thank you bash-3.00# cd /usr/sunvts/bin/ bash-3.00# ls bios.bin iobushangscript.sh stopsunvts vtsprobe cmos.bin javabridge.jar sunlink vtsreportgenerate dispatcher loadVtsServer svmVolDiskList vtstalk env6test... (6 Replies)
Discussion started by: incredible
6 Replies

5. Hardware

Sun/Oracle M5000 Question

I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet? ... (2 Replies)
Discussion started by: desertdenizen
2 Replies

6. IP Networking

M5000 Xscf

I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip. it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out. so my question is, any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies

7. Solaris

M5000 fails to boot

I have an m5000 that Is down. I have access to XSCF> and was able to get to the ok prompt. However, on >ok boot it failed to boot. erred with : svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL. Nov 29... (3 Replies)
Discussion started by: goya
3 Replies

8. AIX

IBM Power 740 won't boot after firmware update

A team member installed the wrong version of License Code on a Power 740 system used in our Development environment. The system will no longer boot. Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies

9. UNIX for Beginners Questions & Answers

Bash script won't run because hardware won't produce display

Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
APCSMART-OLD(8) 						    NUT Manual							   APCSMART-OLD(8)

NAME
apcsmart-old - Driver for American Power Conversion Smart Protocol UPS equipment SYNOPSIS
apcsmart-old -h apcsmart-old -a UPS_NAME [OPTIONS] Note This man page only documents the hardware-specific features of the apcsmart-old driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
apcsmart-old should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and Back-UPS Pro lines. The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible. Some older hardware may only report a handful of variables. This is usually not a bug--they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.networkupstools.org/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0 soft shutdown or powerdown, depending on battery status 1 soft shutdown followed by powerdown 2 instant power off 3 power off with grace period 4 "force OB" hack method for CS 350 Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. Mode 4 exploits an oddity in the CS 350 models since they only seem to support the S command, but then only when running on battery. As a result, the driver will force the UPS to go on battery if necessary before sending the shutdown command. This ensures that the load gets reset. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. APC UPS models with both USB and serial ports require a power cycle when switching from USB communication to serial, and perhaps vice versa. AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the original apcsmart driver by Russell Kroll). This driver was called newapc for a time and was renamed in the 1.5 series. In 2.6.2 the driver was renamed to apcsmart-old, being superseded by updated version with new features. SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 APCSMART-OLD(8)
All times are GMT -4. The time now is 02:34 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy