06-19-2018
Quote:
Originally Posted by
goya
no support since its older. just a company that swaps parts. I did try the power on each domain and same result , did no reset fault, what command does that? I will try and find it.
From the XSCF use the command
version -c xcp and send the output. Depending on the version you might not be able to reset the error...
This User Gave Thanks to DukeNuke2 For This Post:
9 More Discussions You Might Find Interesting
1. AIX
Hello:
NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies
2. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. Hardware
I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?
... (2 Replies)
Discussion started by: desertdenizen
2 Replies
6. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
7. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
8. AIX
A team member installed the wrong version of License Code on a Power 740 system used in our Development environment.
The system will no longer boot.
Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
9. UNIX for Beginners Questions & Answers
Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
LEARN ABOUT REDHAT
lvmchange
LVMCHANGE(8) System Manager's Manual LVMCHANGE(8)
NAME
lvmchange - change attributes of the logical volume manager
SYNOPSIS
lvmchange [-d|--debug] [-f|--force] [-h|--help] {[-i|--iop_verion]| [-R|--reset]} [-v|--verbose]
DESCRIPTION
lvmchange allows you to reset the logical volume manager. Please be careful to have all logical volumes closed and/or unused!
OPTIONS
-d, --debug
Enables additional debugging output (if compiled with DEBUG).
-f, --force
Force the action without confirmation.
-h, --help
Print a usage message on standard output and exit successfully.
-i, --iop_version
Display the LVM io protocol version. This version number ensures that no incompatible data is passed to the driver.
-R, --reset
Emergency reset of the logical volume manager. This function is a "last resort" if something goes wrong to allow the the logical
volume manager module to be unloaded. Not used in normal operation. Please be careful NOT to reset when logical volumes are in
use!!!
-v, --verbose
Gives verbose information about lvmchange's activities.
Example
"lvmchange -fR" resets the logical volume manager without confirmation.
DIAGNOSTICS
lvmchange returns an exit code of 0 for success or > 0 for error:
1 error opening logical volume manager
2 error resetting logical volume manager
95 driver/module not in kernel
96 invalid I/O protocol version
97 error locking logical volume manager
99 invalid command line
See also
lvm(8), vgcreate(8), lvcreate(8)
AUTHOR
Heinz Mauelshagen <Linux-LVM@Sistina.com>
Heinz Mauelshagen LVM TOOLS LVMCHANGE(8)