I'm trying to configure Etherchannel on AIX 5.3 and I'm having some problems. I am aggregating both of the onboard NIC's (ent0 and ent1) into a new adapter ent2 for failover reasons obviously. At first I was experiencing a problem where about 50% of all my packets would be dropped. Then after... (4 Replies)
I have 1 AIX server, 4 dual ported fiber attached ethernet cards and 4 VLANS coming in. Is it possible to present those 8 ports as 1 IP address using etherchannel? Thanks. (5 Replies)
I have one p5 server, no lpar, 2 physical network adapter, bundle as one EtherChannel. The two 2 physical network adapter connect to 2 network switches.
How to make this as a redundancy config?
Current is if one physical network adapter down, the seond one will go through the network. but if... (2 Replies)
I have few AIX servers in my data center, which have their EtherChannel configured to have a fat pipe (active/active) and a nagios server to monitor the server uptimes. Nagios server pings every server in the data center and we have pretty much every known unix flavor in this data center. When... (3 Replies)
Hi,
I have a AIX5.3 P6-520 with 8x1Gb Ethernet ports with possible connections to 2 CISCO 2960 switches.
I can create 8023ad Etherchannels which work correctly with the switches (I have set up for LACP passive and a valid channels)
But can create 2x 8023ad 4Gb Etherchannels with no backups.... (2 Replies)
hi guys,
i need to develop following setup for a customer:
high availability oracle database on aix7 and linux in 2 different LPAR using dual ps700 blande a ds3400 and HMC.
the question is, it is possible to have automatic vioc failover(aix,linux) when for example 1 vios goes down?
in... (6 Replies)
Hi Guys,
I am trying to test an etherchannel failover and switchback.
I did failover from primary to backup adapter, but now I am not able to switch it back to primary.
phcxxxxx:/ > entstat -d ent4 | grep Active
Active channel: backup adapter ... (1 Reply)
Hi,
I'm a newbie to PowerVM and LPARs ( I work with VmWare and Oracle VM Server for Sparc) .recently we purchased an 8202-e4b server, with two enclosures for add'l disk capacity. it is licensed for PowerVM standard,came preloaded as such, AIX 7.1.
I've set up HMC v8.2, and run it through a VM on... (30 Replies)
Hello,
After installing on P6 which is POWERVM IVM VIOS enabled (VET CODE D21C77ACD9229817CA1F00002C10004164 )
i get this message
"I/O hosting requires a hosting partition - boot not permitted".
HMC was connected to the machine
then HMC was removed through ASMI
Searching on... (2 Replies)
Discussion started by: filosophizer
2 Replies
LEARN ABOUT SUNOS
asadmin-create-resource-adapter-config
asadmin-create-resource-adapter-config(1AS) User Commands asadmin-create-resource-adapter-config(1AS)NAME
asadmin-create-resource-adapter-config, create-resource-adapter-config - creates the configuration information in
domain.xml for the connector module
SYNOPSIS
create-resource-adapter-config --user admin_user [--password admin_password] [--host localhost] [--port 4848] [--secure|-s] [--passwordfile
filename] [--terse=false] [--echo=false] [--interactive=true] [--threadpools threadpoolids] [--property name=value[:name=value]*] raname
Creates configuration information for the connector module. This command can be executed prior to deploying a resource adapter, so that the
configuration information is available at the time of deployment, or after deployment. If the resource adapter is created after deployment,
the resource adapter is started. You must first create a threadpool, using the create-threadpool command, and then identify that threadpool
value as the ID in the--threadpools option.
This command is supported in remote mode only.
OPTIONS --user authorized domain application server administrative username.
--password password to administer the domain application server.
--host machine name where the domain application server is running.
--port port number of the domain application server listening for administration requests.
--secure if true, uses SSL/TLS to communicate with the domain application server.
--passwordfile file containing the domain application server password.
--terse indicates that any output data must be very concise, typically avoiding human-friendly sentences and favoring well-
formatted data for consumption by a script. Default is false.
--echo setting to true will echo the command line statement on the standard output. Default is false.
--interactive if set to true (default), only the required password options are prompted.
--threadpool the threadpool ID from which the work manager gets the thread.
--property configuration properties of the resource adapter java bean.
OPERANDS
raname the value kept in the resource-adapter-name in the domain.xml file.
Example 1: Using create-resource-adapter-config
asadmin> create-resource-adapter-config --username admin1 --password adminadmin
myresourceadapter
Command create-resource-adapter-config executed successfully
EXIT STATUS
0 command executed successfully
1 error in executing the command
asadmin-create-threadpool(1AS), asadmin-delete-resource-adapter-config(1AS), asadmin-list-resource-adapter-configs(1AS)J2EE 1.4 SDK March 2004 asadmin-create-resource-adapter-config(1AS)