Operating Systems AIX PowerVM SEA etherchannel performance ? Post 303018531 by vilius on Saturday 9th of June 2018 08:42:55 AM
Old 06-09-2018
largesend=1 is default on my vios version - tried large_receive=yes - no change same result 1.4-1.8Gbit speed.
 

10 More Discussions You Might Find Interesting

1. AIX

Problem with Etherchannel

I'm trying to configure Etherchannel on AIX 5.3 and I'm having some problems. I am aggregating both of the onboard NIC's (ent0 and ent1) into a new adapter ent2 for failover reasons obviously. At first I was experiencing a problem where about 50% of all my packets would be dropped. Then after... (4 Replies)
Discussion started by: acascianelli
4 Replies

2. AIX

AIX / Etherchannel / VLANs

I have 1 AIX server, 4 dual ported fiber attached ethernet cards and 4 VLANS coming in. Is it possible to present those 8 ports as 1 IP address using etherchannel? Thanks. (5 Replies)
Discussion started by: jwholey
5 Replies

3. AIX

Can EtherChannel be a redundancy config?

I have one p5 server, no lpar, 2 physical network adapter, bundle as one EtherChannel. The two 2 physical network adapter connect to 2 network switches. How to make this as a redundancy config? Current is if one physical network adapter down, the seond one will go through the network. but if... (2 Replies)
Discussion started by: rainbow_bean
2 Replies

4. AIX

EtherChannel interface ping pelicularity

I have few AIX servers in my data center, which have their EtherChannel configured to have a fat pipe (active/active) and a nagios server to monitor the server uptimes. Nagios server pings every server in the data center and we have pretty much every known unix flavor in this data center. When... (3 Replies)
Discussion started by: thenomad
3 Replies

5. AIX

Aggregated Etherchannel

Hi, I have a AIX5.3 P6-520 with 8x1Gb Ethernet ports with possible connections to 2 CISCO 2960 switches. I can create 8023ad Etherchannels which work correctly with the switches (I have set up for LACP passive and a valid channels) But can create 2x 8023ad 4Gb Etherchannels with no backups.... (2 Replies)
Discussion started by: spitzie
2 Replies

6. AIX

PowerVM HA questions

hi guys, i need to develop following setup for a customer: high availability oracle database on aix7 and linux in 2 different LPAR using dual ps700 blande a ds3400 and HMC. the question is, it is possible to have automatic vioc failover(aix,linux) when for example 1 vios goes down? in... (6 Replies)
Discussion started by: gullio23
6 Replies

7. AIX

Need IBM PowerVM

Hi all please give me a link for IBM PowerVM (4 Replies)
Discussion started by: babinlonston
4 Replies

8. AIX

Etherchannel failover testing

Hi Guys, I am trying to test an etherchannel failover and switchback. I did failover from primary to backup adapter, but now I am not able to switch it back to primary. phcxxxxx:/ > entstat -d ent4 | grep Active Active channel: backup adapter ... (1 Reply)
Discussion started by: snchaudhari2
1 Replies

9. AIX

PowerVM/lpar creation problems

Hi, I'm a newbie to PowerVM and LPARs ( I work with VmWare and Oracle VM Server for Sparc) .recently we purchased an 8202-e4b server, with two enclosures for add'l disk capacity. it is licensed for PowerVM standard,came preloaded as such, AIX 7.1. I've set up HMC v8.2, and run it through a VM on... (30 Replies)
Discussion started by: computron
30 Replies

10. AIX

Powervm ivm vios

Hello, After installing on P6 which is POWERVM IVM VIOS enabled (VET CODE D21C77ACD9229817CA1F00002C10004164 ) i get this message "I/O hosting requires a hosting partition - boot not permitted". HMC was connected to the machine then HMC was removed through ASMI Searching on... (2 Replies)
Discussion started by: filosophizer
2 Replies
HY(4)							     Kernel Interfaces Manual							     HY(4)

NAME
hy - Network Systems Hyperchannel interface SYNOPSIS
/sys/conf/SYSTEM: NHY hy_controllers # Hyperchannel DESCRIPTION
The hy interface provides access to a Network Systems Corporation Hyperchannel Adapter. The network to which the interface is attached is specified at boot time with an SIOCSIFADDR ioctl. The host's address is discovered by reading the adapter status register. The interface will not transmit or receive packets until the network number is known. DIAGNOSTICS
hy%d: unit number 0x%x port %d type %x microcode level 0x%x. Identifies the device during autoconfiguration. hy%d: can't handle af%d. The interface was handed a message with addresses formatted in an unsuitable address family; the packet was dropped. hy%d: can't initialize. The interface was unable to allocate UNIBUS resources. This is usually due to having too many network devices on an 11/750 where there are only 3 buffered data paths. hy%d: NEX - Non Existent Memory. Non existent memory error returned from hardware. hy%d: BAR overflow. Bus address register overflow error returned from hardware. hy%d: Power Off bit set, trying to reset. Adapter has lost power, driver will reset the bit and see if power is still out in the adapter. hy%d: Power Off Error, network shutdown. Power was really off in the adapter, network connections are dropped. Software does not shut down the network unless power has been off for a while. hy%d: RECVD MP > MPSIZE (%d). A message proper was received that is too big. Probable a driver bug. Shouldn't happen. hy%d: xmit error - len > hy_olen [%d > %d]. Probable driver error. Shouldn't happen. hy%d: DRIVER BUG - INVALID STATE %d. The driver state machine reached a non-existent state. Definite driver bug. hy%d: watchdog timer expired. A command in the adapter has taken too long to complete. Driver will abort and retry the command. hy%d: adapter power restored. Software was able to reset the power off bit, indicating that the power has been restored. SEE ALSO
intro(4N), inet(4F) BUGS
If the adapter does not respond to the status command issued during autoconfigure, the adapter is assumed down. A reboot is required to recognize it. The adapter power fail interrupt seems to occur sporadically when power has, in fact, not failed. The driver will believe that power has failed only if it can not reset the power fail latch after a ``reasonable'' time interval. These seem to appear about 2-4 times a day on some machines. There seems to be no correlation with adapter rev level, number of ports used etc. and whether a machine will get these ``bogus powerfails''. They don't seem to cause any real problems so they have been ignored. 3rd Berkeley Distribution August 20, 1987 HY(4)
All times are GMT -4. The time now is 04:52 PM.