Does the new disk have the same or more LBA's as the others in the array? Sometimes like models of disk have a slightly different (less) number of LBA's (sectors). The LBA capacity is often on the disk label.

The fact that the error displayed on rebuild completion indicates to me that the RAID controller is not happy with that drive for some reason.

You could initiate another rebuild but the same will probably happen again; but worth a try. Otherwise, replace the disk again.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
SG_GET_LBA_STATUS(8)						     SG3_UTILS						      SG_GET_LBA_STATUS(8)

NAME
sg_get_lba_status - send the SCSI GET LBA STATUS command SYNOPSIS
sg_get_lba_status [--brief] [--help] [--hex] [--lba=LBA] [--maxlen=LEN] [--raw] [--verbose] [--version] DEVICE DESCRIPTION
Send the SCSI GET LBA STATUS command to the DEVICE and outputs the response. This command was introduced in (draft) SBC-3 revision 20 and devices that support logical block provisioning should support this command. The default action is to decode the response into one LBA status descriptor per line output to stdout. The descriptor LBA is output in hex (prefixed by '0x') and the number of blocks is output in decimal followed by the provisioning status in decimal. The provisioning status can be in the range 0 to 15 of which only 0 (mapped), 1 (unmapped) and 2 (anchored) are used currently. The amount of output can be reduced by the --brief option. OPTIONS
Arguments to long options are mandatory for short options as well. -b, --brief when use once then one LBA status descriptor per line is output to stdout. Each line has this format: "0x<descriptor_LBA> 0x<blocks> <provisioning_status>". So the descriptor LBA and blocks are output in hex and the provisioning status in decimal. When used twice (e.g. '-bb' or '--brief --brief') the the provisioning status of the given LBA (or LBA 0 if the --lba option is not given) is output to stdout. A check is made that the given LBA lies on the range of the first returned LBA status descriptor (as it should according to SBC-3 revision 20) and warnings are sent to stderr if it doesn't. -h, --help output the usage message then exit. -H, --hex output response to this command in ASCII hex. -l, --lba=LBA where LBA is the starting Logical Block Address (LBA) to check the provisioning status for. Note that the DEVICE chooses how many following blocks that it will return provisioning status for. -m, --maxlen=LEN where LEN is the (maximum) response length in bytes. It is placed in the cdb's "allocation length" field. If not given then 24 is used. 24 is enough space for the response header and one LBA status descriptor. LEN should be 8 plus a multiple of 16 (e.g. 24, 40, and 56 are suitable). -r, --raw output response in binary (to stdout). -v, --verbose increase the level of verbosity, (i.e. debug output). Additional output caused by this option is sent to stderr. -V, --version print the version string and then exit. NOTES
In SBC-3 revision 25 the calculation associated with the Parameter Data Length field in the response was modified. Prior to that the byte offset was 8 and in revision 25 it was changed to 4. For a discussion of logical block provisioning see section 4.7 of sbc3r29.pdf at http://www.t10.org (or the corresponding section of a later draft). EXIT STATUS
The exit status of sg_get_lba_status is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2009-2012 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_write_same(8), sg_unmap(8) sg3_utils-1.33 January 2012 SG_GET_LBA_STATUS(8)
All times are GMT -4. The time now is 09:13 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy