Sponsored Content
Operating Systems AIX DISK ARRAY PROTECTION SUSPENDED message following disk replacement Post 303016334 by hicksd8 on Tuesday 24th of April 2018 03:43:48 PM
Old 04-24-2018
Does the new disk have the same or more LBA's as the others in the array? Sometimes like models of disk have a slightly different (less) number of LBA's (sectors). The LBA capacity is often on the disk label.

The fact that the error displayed on rebuild completion indicates to me that the RAID controller is not happy with that drive for some reason.

You could initiate another rebuild but the same will probably happen again; but worth a try. Otherwise, replace the disk again.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
disklabel(4)						     Kernel Interfaces Manual						      disklabel(4)

NAME
disklabel - Disk pack label SYNOPSIS
#include <sys/disklabel.h> DESCRIPTION
Each disk or disk pack on a system may contain a disk label which provides detailed information about the geometry of the disk and the par- titions into which the disk is divided. It should be initialized when the disk is formatted, and may be changed later with the disklabel program. This information is used by the system disk driver and by the bootstrap program to determine how to program the drive and where to find the file systems on the disk partitions. Additional information is used by the file system in order to use the disk most effi- ciently and to locate important file system information. The description of each partition contains an identifier for the partition type (standard file system, swap area, etc.). The file system updates the in-core copy of the label if it contains incomplete information about the file system. The label is located in sector number LABELSECTOR of the drive, usually sector 0 (zero) where it may be found without any information about the disk geometry. It is at an offset LABELOFFSET from the beginning of the sector, to allow room for the initial bootstrap. The disk sector containing the label is normally made read-only so that it is not accidentally overwritten by pack-to-pack copies or swap opera- tions; the DIOCWLABEL ioctl, which is done as needed by the disklabel program, allows modification of the label sector. A copy of the in-core label for a disk can be obtained with the DIOCGDINFO ioctl; this works with a file descriptor for a block or charac- ter (raw) device for any partition of the disk. The in-core copy of the label is set by the DIOCSDINFO ioctl. The offset of a partition cannot generally be changed, nor made smaller while it is open. One exception is that any change is allowed if no label was found on the disk, and the driver was able to construct only a skeletal label without partition information. Finally, the DIOCWDINFO ioctl operation sets the in-core label and then updates the on-disk label; there must be an existing label on the disk for this operation to succeed. Thus, the initial label for a disk or disk pack must be installed by writing to the raw disk. All of these operations are normally done using the disklabel program. RELATED INFORMATION
Files: disktab(4) Commands: disklabel(8) delim off disklabel(4)
All times are GMT -4. The time now is 07:43 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.