Sponsored Content
Operating Systems AIX DISK ARRAY PROTECTION SUSPENDED message following disk replacement Post 303016334 by hicksd8 on Tuesday 24th of April 2018 03:43:48 PM
Old 04-24-2018
Does the new disk have the same or more LBA's as the others in the array? Sometimes like models of disk have a slightly different (less) number of LBA's (sectors). The LBA capacity is often on the disk label.

The fact that the error displayed on rebuild completion indicates to me that the RAID controller is not happy with that drive for some reason.

You could initiate another rebuild but the same will probably happen again; but worth a try. Otherwise, replace the disk again.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
MBRLABEL(8)						    BSD System Manager's Manual 					       MBRLABEL(8)

NAME
mbrlabel -- update disk label from MBR label(s) SYNOPSIS
mbrlabel [-fqrw] [-s sector] device DESCRIPTION
mbrlabel is used to update a NetBSD disk label from the Master Boot Record (MBR) label(s) found on disks that were previously used on DOS/Windows systems (or other MBR using systems). mbrlabel scans the MBR contained in the very first block of the disk (or the block specified through the -s flag), then walks through every extended partition found and generates additional partition entries for the disk from the MBRs found in those extended partitions. Each MBR partition which does not have an equivalent partition in the disk label (equivalent in having the same size and offset) is added to the first free partition slot in the disk label. A free partition slot is defined as one with an fstype of 'unused' and a size of zero ('0'). If there are not enough free slots in the disk label, a warning will be issued. The raw partition (typically partition c, but d on i386 and some other platforms) is left alone during this process. By default, the proposed changed disk label will be displayed and no disk label update will occur. Available options: -f Force an update, even if there has been no change. -q Performs operations in a quiet fashion. -r In conjunction with -w, also update the on-disk label. -s sector Specifies the logical sector number that has to be read from the disk in order to find the MBR. Useful if the disk has remapping drivers on it and the MBR is located in a non-standard place. Defaults to 0. -w Update the in-core label if it has been changed. See also -r. SEE ALSO
disklabel(8), dkctl(8), fdisk(8), mbr(8) HISTORY
The mbrlabel command appeared in NetBSD 1.4. BSD
April 5, 2010 BSD
All times are GMT -4. The time now is 01:13 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy