Sponsored Content
Operating Systems AIX DISK ARRAY PROTECTION SUSPENDED message following disk replacement Post 303016332 by terrya on Tuesday 24th of April 2018 03:38:34 PM
Old 04-24-2018
The rebuild happened. I was watching the status of the rebuild and when it completed, that was when the status of the disk array showed as degraded.

We're not seeing any other disk in the process of failing, though. No other errpt messages other than the one displayed immediately after the replacement.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
voldiskadm(8)						      System Manager's Manual						     voldiskadm(8)

NAME
voldiskadm - Menu interface for LSM disk administration SYNOPSIS
/usr/sbin/voldiskadm DESCRIPTION
The voldiskadm script is an interactive tool that presents a menu of possible operations to the user. When an operation is selected, the script guides the user through the necessary steps, and prompts for data needed to complete the operation. The voldiskadm interface is intended mainly for beginning users and for those who prefer a simple method for doing common operations. The interface uses query-based prompts to gather input, with defaults supplied when possible. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. For operations that require a device name, one or more names can be specified using a space-separated list. Names in the list can have the form dskn or rdskn (for an entire disk) or dsknp or rdsknp (for a specific disk partition). Disk names relate directly to device names in the /dev/disk and /dev/rdisk directories. The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadm. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadm menu includes the following options: Add or initialize one or more disks This option prompts for one or more disk device addresses. The specified disks can be added to an existing disk group, added to a new disk group, added to a disk group as spares, or initialized but not added to a disk group (reserved for use as replacement disks). After specifying the disks, the user is prompted for a disk group (rootdg by default) and a disk name. If no name is specified, a default disk name is assigned (diskn for disks in the rootdg disk group and diskgroupn for disks in other disk groups). The disks are then checked to ensure that there is no information already on them. If there is, the user is given the option of encapsulating the disks. Encapsulate one or more disks This option prompts for one or more disk addresses. It then calls volencap to encapsulate the specified partitions. Remove a disk This option prompts for a disk, by disk media name. The disk is checked to ensure that no subdisks reside on the disk. If the disk is in use, the operation fails with a recommendation to first move all volumes off the disk. If this disk is the last disk in a disk group, the user is prompted for whether the disk group should be removed from the system, as well. The operation proceeds by calling voldg rmdisk to remove the disk from its disk group. If this is the last disk in its disk group, voldg deport is used, instead, to remove the disk group from use. Remove a disk for replacement This option prompts for a disk, by disk media name. The disk is checked for volumes that would lose all mirrors as a result of the operation. If such volumes exist, they are listed and the user is prompted to ensure that the operation should proceed. The operation proceeds by calling voldg -k rmdisk to dissociate the media record from the physical disk. If some formatted disks are under LSM control but not assigned to a disk group, the user is prompted for whether one of these disks should be used as a replacement. Replace a failed or removed disk This option prompts for a disk media name. The named media record must be dissociated from a disk. If the media record is not in the removed state, unused disks are scanned for matching disk IDs. If a disk with a matching disk ID is found, the user is prompted for whether that disk should be reattached. If a matching disk is not used, the user is prompted for a new disk, by device name. If the named replacement disk has a valid disk header, but is not allocated to a disk group, the user is prompted for whether the disk should be reinitialized. If the named replacement disk is listed as allocated to a disk group or to another host, the user is prompted to ensure that the operation should proceed. If the device is to be initialized, a new disk label is written to the disk to reflect its private and public regions. Given an initialized disk, the operation proceeds by replacing the disk in a disk group with voldg -k adddisk. Mirror volumes on a disk This option prompts for a disk, by disk media name. It then prompts for a destination disk within the same disk group, also by disk media name. Specifying no destination disks indicates that any disk is suitable. The operation proceeds by calling volmirror to mirror the volumes. Mirroring volumes from the boot disk will produce a disk that can be used as an alternate boot disk. This is done by calling the volrootmir command. Move volumes from a disk This option prompts for a disk, by disk media name. It then prompts for a possible list of destination disks, also by disk media name. Specifying no destination disks indicates that any disk is suitable. The operation proceeds by calling volevac to move sub- disks off the disk. Enable access to (import) a disk group This option prompts for a disk, by device address. The operation proceeds by calling voldg import to import the disk group stored on that disk. Disable access to (deport) a disk group This option prompts for a disk group name. The prompt display lists alternate disk groups and the disks (media name and access name) that they contain. The operation proceeds by calling voldg deport. Enable (online) a disk device This option prompts for a disk device. The prompt display allows for a display of disks on the system. The operation only func- tions for disks currently in an offline state. It then proceeds to make the disk accessible. Disable (offline) a disk device This option prompts for a disk device. The prompt display allows for a display of disks on the system. The operation only func- tions for disks currently in an online state but not part of any disk group. It then proceeds to mark the disk as offline such that the Logical Storage Manager makes no further attempt at accessing the disk. Mark a disk as a spare for a disk group This option sets up a disk to be used as a spare device for its disk group. A spare disk can be used to automatically replace a disk that has failed. No space can be used on a disk that is marked as a spare. Turn off the spare flag for a disk This option removes a disk from those that can be used as a spare and returns its space to the general pool of available space. Recover plexes and volumes after replacement This operation performs plex attachment, RAID-5 subdisk recovery, and resynchronize operations for the named volumes, or for volumes residing on the named disks (media name). If no media name or volume operands are specified, the operation applies to all volumes (or to all volumes in the specified disk group). ERRORS
See the voldiskadd(8) reference page for a description of errors related to the initialization operation. FILES
A list of disks to exclude from use by voldiskadm. SEE ALSO
disklabel(8), volintro(8), voldg(8), voldisk(8), voldiskadd(8), voldisksetup(8), volrootmir(8) voldiskadm(8)
All times are GMT -4. The time now is 04:01 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy