Sponsored Content
Operating Systems AIX DISK ARRAY PROTECTION SUSPENDED message following disk replacement Post 303016331 by hicksd8 on Tuesday 24th of April 2018 03:22:46 PM
Old 04-24-2018
I'm not an AIX/IBM expert but, talking generically, array degraded always means that there is no resilience because a disk needs replacing, or an array rebuild has failed for some reason e.g. the new disk does not have enough LBA's, has bad sectors, has also failed, or whatever.

Did the rebuild happen? Could you see substantial activity for a period? Or is that rebuild still running?????

Try re-seating the new drive again and initiate another rebuild.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie: Sun Ultra 5 Disk Replacement

I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies

2. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

3. Red Hat

Hard disk replacement

Hi all, I need some help with a RHEL 4 on a Sun Fire v65x machine. Some of the disks is damaged or has a hardware issue. This disk is connected to a hardware raid. The problem is that I don't know what is the brand, model and capacity of the disk. I've read the raid manual, but says... (3 Replies)
Discussion started by: adelgadom
3 Replies

4. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

5. HP-UX

need your help for HP virtual array 7400 disk replacement error

hi all! I found a the state of disk at JA0/D13 was failed this morning. then i replaced it this afternoon,but i run #dsp -s the array status displayed ==================================== STATUS Subsystem State: 1 The Subsystem is TESTING. The array is REBUILDING and is 87%... (0 Replies)
Discussion started by: JoyOnLine
0 Replies

6. AIX

errpt kept sending errors after disk replacement

Hi, The system is a Power6 8204 with an external storage 7031. OS is AIX 5.3. I replaced a failed disk hdisk28 and put it back to the volume group. Everything looks just fine. After the replacement, errpt has kept sending "Perm DISK OPERATION ERROR". Other than the error, everything still... (1 Reply)
Discussion started by: aixlover
1 Replies

7. Solaris

encapsulated root disk replacement

Hello, I have a Sparc system with encapsulated disks. Because of disk errors I had to replace rootdisk, I did it with vxdiskadm 4) replacement, vxdctl disable/enable, vxdiskadm 5) After it it the system boot failed, dropped back to the ok> prompt, message was: The file... (0 Replies)
Discussion started by: ggi
0 Replies

8. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

9. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
MLX(4)                                                     BSD Kernel Interfaces Manual                                                     MLX(4)

NAME
mlx -- Mylex DAC-family RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device mlx Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mlx_load="YES" DESCRIPTION
The mlx driver provides support for Mylex DAC-family PCI to SCSI RAID controllers, including versions relabeled by Digital/Compaq. HARDWARE
Controllers supported by the mlx driver include: o Mylex DAC960P o Mylex DAC960PD / DEC KZPSC (Fast Wide) o Mylex DAC960PDU o Mylex DAC960PL o Mylex DAC960PJ o Mylex DAC960PG o Mylex DAC960PU / DEC PZPAC (Ultra Wide) o Mylex AcceleRAID 150 (DAC960PRL) o Mylex AcceleRAID 250 (DAC960PTL1) o Mylex eXtremeRAID 1100 (DAC1164P) o RAIDarray 230 controllers, aka the Ultra-SCSI DEC KZPAC-AA (1-ch, 4MB cache), KZPAC-CA (3-ch, 4MB), KZPAC-CB (3-ch, 8MB cache) All major firmware revisions (2.x, 3.x, 4.x and 5.x) are supported, however it is always advisable to upgrade to the most recent firmware available for the controller. Compatible Mylex controllers not listed should work, but have not been verified. DIAGNOSTICS
Controller initialisation phase mlx%d: controller initialisation in progress... mlx%d: initialisation complete The controller firmware is performing/has completed initialisation. mlx%d: physical drive %d:%d not responding The drive at channel:target is not responding; it may have failed or been removed. mlx%d: spinning up drives... Drive startup is in progress; this may take several minutes. mlx%d: configuration checksum error The array configuration has become corrupted. mlx%d: mirror race recovery in progress mlx%d: mirror race on a critical system drive mlx%d: mirror race recovery failed These error codes are undocumented. mlx%d: physical drive %d:%d COD mismatch Configuration data on the drive at channel:target does not match the rest of the array. mlx%d: system drive installation aborted Errors occurred preventing one or more system drives from being configured. mlx%d: new controller configuration found The controller has detected a configuration on disk which supersedes the configuration in its nonvolatile memory. It will reset and come up with the new configuration. mlx%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mlx%d: unknown firmware initialisation error %x:%x:%x An unknown error occurred during initialisation; it will be ignored. Driver initialisation/shutdown phase: mlx%d: can't allocate scatter/gather DMA tag mlx%d: can't allocate buffer DMA tag mlx%d: can't allocate s/g table mlx%d: can't make initial s/g list mapping mlx%d: can't make permanent s/g list mapping mlx%d: can't allocate interrupt mlx%d: can't set up interrupt A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. mlx%d: error fetching drive status The current status of all system drives could not be fetched; attachment of system drives will be aborted. mlx%d: device_add_child failed mlx%d: bus_generic_attach returned %d Creation of the system drive instances failed; attachment of one or more system drives may have been aborted. mlxd%d: detaching... The indicated system drive is being detached. mlxd%d: still open, can't detach The indicated system drive is still open or mounted; the controller cannot be detached. mlx%d: flushing cache... The controller cache is being flushed prior to detach or shutdown. Operational diagnostics: mlx%d: ENQUIRY failed - %s mlx%d: ENQUIRY2 failed mlx%d: ENQUIRY_OLD failed mlx%d: FLUSH failed - %s mlx%d: CHECK ASYNC failed - %s mlx%d: REBUILD ASYNC failed - %s mlx%d: command failed - %s The controller rejected a command for the reason given. mlx%d: I/O beyond end of unit (%u,%d > %u) mlx%d: I/O error - %s An I/O error was reported by the controller. mlx%d: periodic enquiry failed - %s An attempt to poll the controller for status failed for the reason given. mlx%d: mlx_periodic_enquiry: unknown command %x The periodic status poll has issued a command which has become corrupted. mlxd%d: drive offline mlxd%d: drive online mlxd%d: drive critical The system disk indicated has changed state. mlx%d: physical drive %d:%d reset mlx%d: physical drive %d:%d killed %s mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x mlx%d: info %4D csi %4D The drive at channel:target has been reset, killed for the given reason, or experienced a SCSI error. mlx%d: unknown log message type %x mlx%d: error reading message log - %s An error occurred while trying to read the controller's message log. mlxd%d: consistency check started mlx%d: consistency check completed A user-initiated consistency check has started/completed. mlx%d: drive rebuild started for %d:%d mlx%d: drive rebuild completed A user-initiated physical drive rebuild has started/completed. mlx%d: background check/rebuild operation started mlx%d: background check/rebuild operation completed An automatic system drive consistency check or physical drive rebuild has started/completed. mlx%d: channel %d pausing for %d seconds mlx%d: channel %d resuming mlx%d: pause command failed - %s mlx%d: pause failed for channel %d mlx%d: resume command failed - %s mlx%d: resume failed for channel %d Controller/channel pause operation notification. (Channel pause is not currently supported on any controller.) mlx%d: controller wedged (not taking commands) The controller is not responding to attempts to submit new commands. mlx%d: duplicate done event for slot %d mlx%d: done event for nonbusy slot %d Corruption has occurred in either the controller's onboard list of commands or in the driver. SEE ALSO
mlxcontrol(8) AUTHORS
The mlx driver was written by Michael Smith <msmith@FreeBSD.org>. This manual page was written by Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org> and Michael Smith <msmith@FreeBSD.org>. BUGS
The driver does not yet support EISA adapters. The DEC KZPSC has insufficient flash ROM to hold any reasonably recent firmware. This has caused problems for this driver. The driver does not yet support the version 6.x firmware as found in the AcceleRAID 352 and eXtremeRAID 2000 and 3000 products. BSD August 10, 2004 BSD