Sponsored Content
Full Discussion: Zpool mirroring
Operating Systems Solaris Zpool mirroring Post 303015188 by Peasant on Friday 30th of March 2018 12:12:18 AM
Old 03-30-2018
Yes, will hot spare added to pool and if autoreplace option is on in the zpool the following will happen.

1. FMA agent detects a fault and replaces the failed device with spare.
2. When the failed disk is replaced and resilvered, hot spare disk is detached and added back to the pool as hot spare.

Other then that, if the option is not defined, the administrator will need to do option 2 by hand.

This is documented quite well.

Regards
Peasant.
 

10 More Discussions You Might Find Interesting

1. Solaris

need zpool to revert...

hi i have created a pool using zpool command for my /dev/dsk/c1d0s3 disk. The poolname is qwertyuiopasdfghjklmnbvcxzzxcvbnmasdfghjklqwertyuiopoiuytrewqasdfghjklkjhgfdsazxcvbnmmnbnbcxczxzassd ddddvfhfghgjjgjhgkhkljfjlhohihiuyuioyguioyguiowyuiogwyuigwrigywuigyguiyuiogyugiyguioyuyguiowygiuygui... (1 Reply)
Discussion started by: SankarV
1 Replies

2. Solaris

ZPOOL help..

hi ... i have added a physical disk to the pool with ""zpool add <poolname> diskname"""... after that i realized that i have to mirror it instead..then i tried to take that disk out of the pool but i m not able to do that.. i have gone through many unix help sites , nothing worked , so please... (6 Replies)
Discussion started by: yrajendergoud
6 Replies

3. Solaris

Zpool backup and restore

hi, my requirement goes something like this: In current setup, we have SPARC server running Solaris10 5/08. Out of 3 HDD available, 2 HDD (other than root) were zpool-ed and 3 zones were created. Now, we have bought a new server with similar H/W config and planning to move the zones... (1 Reply)
Discussion started by: EmbedUX
1 Replies

4. Solaris

Amount of LUNs used for zpool

Hi folks, is there any rule or best practise for amount of LUNs user for zpool construction (from view of performance etc.)?? THX (4 Replies)
Discussion started by: brusell
4 Replies

5. Solaris

Zpool query

Hi, I have an X86pc with Solaris 10 and ZFS system. It has 8 similar disks. I need help in creating some zpools and changing the mount-point of a slice. Currently, the zpool in my system is like this: root@abcxxx>zpool status pool: rpool state: ONLINE scrub: none requested... (4 Replies)
Discussion started by: mystition
4 Replies

6. Solaris

How to tell what disks are used for a zpool?

Hello, Does anyone know how I can tell what disk are being not being used by a zpool? For example in Veritas Volume manager, I can run a "vxdisk list" and disks that are marked as "online invalid" are disk that are not used. I'm looking for a similar command in ZFS which will easily show... (5 Replies)
Discussion started by: robertinoau
5 Replies

7. Solaris

Add disk to zpool

Hi, Quick question. I have a data zpool that consists of 1 disk. pool: data state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM data ONLINE 0 0 0 c0t50002AC0014B06BEd0 ONLINE... (2 Replies)
Discussion started by: general_lee
2 Replies

8. UNIX for Advanced & Expert Users

R5 zpool in corrupted state

Hi All, I am getting zpool corrupted message under zpool status command.What could be the reason for this.I had observed this zpool was full this morning after this i am seeing this error. $PWD>zpool status -xv R5 pool: R5 state: DEGRADED status: One or more devices has experienced... (0 Replies)
Discussion started by: sahil_shine
0 Replies

9. Solaris

Shrinking zpool

Hello experts, I have a solaris 10 (SunOS 5.10 Generic_148888-05 sun4u sparc SUNW,SPARC-Enterprise) that by mistake I added a second san space of 700g to the pool. the whole pool is now 1.2T and, I need to take the space away from the pool and, make the pool 700g total. this is live oracle... (7 Replies)
Discussion started by: afadaghi
7 Replies

10. BSD

Zpool problem

Hi I have a problem with size on zfs filesystem on FreeBSD 9.2-RELEASE-p3. When I do this: free01# df -Th Filesystem Type Size Used Avail Capacity Mounted on /dev/ufs/FreeNASdde ufs 926M 826M 26M 97% / devfs devfs ... (1 Reply)
Discussion started by: primo102
1 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), mount(8), newfs(8), vinum(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 09:10 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy