The Lounge War Stories Data Centre meets Vacuum Cleaner Post 303014219 by gull04 on Wednesday 7th of March 2018 10:52:17 AM
Old 03-07-2018
Hi Joeyg,

You are of course right, however I was advised that this solution was built from disposed of equipment as a short term solution in 2006 and the cover for the ID switch was left in the skip.

Not much help when you are performing the headless chicken dance in the data centre I know, but I'm told that ensuring this won't happen again is now a priority.

I think that they'll probably try and get a cover off aBay, this will probably mean that it will be in service as a temporary solution for an other 12 years.

Regards

Gull04
 

6 More Discussions You Might Find Interesting

1. News, Links, Events and Announcements

The HP-UX Porting and Archive Centre

If you're looking for an easy source of free software for HP-UX, look no further. A consortium of major universities and HP user groups have banded together and operate what is simply the finest free software site in existence. The world's best HP-UX software engineers have ported each package... (0 Replies)
Discussion started by: Perderabo
0 Replies

2. Solaris

Sun Management Centre

Hi Guys, Does anyone ever use Sun MC before? If yes, can u share with me how to do the installation. Thanks (1 Reply)
Discussion started by: raziayub
1 Replies

3. Shell Programming and Scripting

Cleaner method for this if-then statement?

I have a script that runs once per month. It performs a certain task ONLY if the month is January, April, July, or October. MONTH=`date +%m` if || || || ; then do something else do a different thing fi Is there a neater way of doing it than my four separate "or" comparisons? That... (2 Replies)
Discussion started by: lupin..the..3rd
2 Replies

4. Shell Programming and Scripting

Cleaner way to use shell variable in awk /X/,/Y/ syntax?

$ cat data Do NOT print me START_MARKER Print Me END_MARKER Do NOT print me $ cat awk.sh start=START_MARKER end=END_MARKER echo; echo Is this ugly syntax the only way? awk '/'"$start"'/,/'"$end"'/ { print }' data echo; echo Is there some modification of this that would work? awk... (2 Replies)
Discussion started by: hanson44
2 Replies

5. Shell Programming and Scripting

A cleaner way to rearrange column

Hello, I have some tab delimited text data, index name chg_p chg_m 1 name,1 1 0 2 name,2 1 1 3 name,3 1 0 4 name,4 1 0 5 name,5 1 1 I need to duplicate the "index" column, call it "id" and insert it after the... (8 Replies)
Discussion started by: LMHmedchem
8 Replies

6. Shell Programming and Scripting

Maybe a cleaner way to generate a file?

greetings, to be clear, i have a solution but i'm wondering if anyone has a cleaner way to accomplish the following: the variable: LSB_MCPU_HOSTS='t70c7n120 16 t70c7n121 16 t70c7n122 16 t70c7n123 16 t70c7n124 16 t70c7n125 16 t70c7n126 16 t70c7n127 16 t70c7n128 16 t70c7n129 16 t70c7n130 16... (2 Replies)
Discussion started by: crimso
2 Replies
RICHCOMM_USB(8) 						    NUT Manual							   RICHCOMM_USB(8)

NAME
richcomm_usb - Driver UPS equipment using Richcomm dry-contact to USB solution NOTE
This man page only documents the specific features of the richcomm_usb driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
The Richcomm dry-contact to USB solution is a generic interface that is used to upgrade an existing (RS-232) contact closure UPS interface to USB. As such, all the limitations of the underlying contact closure interface apply. This means that you will only get the essentials in ups.status: OL, OB, and LB. See also genericups(8). BUGS
Most contact-closure UPSes will not power down the load if the line power is present. This can create a race when using slave upsmon(8) systems. See the upsmon(8) man page for more information. The solution to both of these problems is to upgrade to a smart protocol UPS of some kind that allows detection and proper load cycling on command. AUTHORS
Peter van Valderen <p.v.valderen at probu.nl>, Dirk Teurlings <dirk at upexia.nl> SEE ALSO
The core driver: nutupsdrv(8) The generic serial driver: genericups(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 RICHCOMM_USB(8)
All times are GMT -4. The time now is 10:02 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy