Hi All,
p_ftp=dummy
time ftp -niv 192.0.0.2 << EOF
user dummy dummy
cd prt/$p_ftp
ascii
ls -ltr
quit
output is
-rw-r--r-- 1 500 500 5137 Mar 04 11:21 dummy.csv
can any one suggest how to get year while using ftp (1 Reply)
Hello,
How do I use grep to find a pattern in a list of file and then display 5 lines after the pattern is matched
Eg:
I want to match the string GetPresentCode in all files in a folder and then see 4 lines following this match. I am not sure if grep is what should be used to achieve. Thanks!... (3 Replies)
Hi
is there a way in grep to display few lines before and after the pattern??
I tried options A and B and after-context and before-context. But they don't work on Solaris platform.
please advise. (13 Replies)
I have to grep on a few words in a file and then display the line containing those words and the line above it.
For ex -
File1.txt contains...
abc xyz abc
This is a test
Test successful
abc xyz abc
Just a test
Test successful
I find the words 'Test successful' in the file... (6 Replies)
Hello everyone.
I would like to know if I can use grep or zgrep to search for a particular pattern then print the x number of lines after the pattern was found.
Lets say for example a pattern was found on line 3, I wanted the output to show lines 3, 4 and 5.
Thanks! (10 Replies)
Hi,
I wanted to grep string "ERROR" and "WORNING" after last occurrence of String "Starting" only and wanted to display two lines after searched ERROR and WORNING string and one line before. I have following cronjob log file "errorlog" file and I have written the code for same in Unix as below... (17 Replies)
Hi,
Need help to grep the following from a file x. I just want to grep exact match not lines and not partial word.
CONFSUCCESS
CONFFAIL
CONFPARTIALSUCCESS
>cat x
xczxczxczc zczczcxx CONFSUCCESS czczczcczc
czxxczxzxczcczc CONFFAIL xczxczcxcczczc
zczczczcz CONFPARTIALSUCCESS czczxcxzc
... (4 Replies)
Hi I need to grep for a patter and display all lines below the pattern.
For ex: say my file has the below lines
file1
file2
file3
file4
file5
I NEED to grep for patter file3 and display all lines below the pattern. do we have an option to get this data. Let me know if you require... (5 Replies)
Hi guys,
I have a log file that generates multiple logs about a query.
<query time='2016-04-13 13:01:50.825'>
<PagingRequestHandler>
<Before>brand:vmu</Before>
<After>brand:vmu</After>
</PagingRequestHandler>
<GroupDeviceFilterHandler>
<Before>brand:vmu</Before>
... (3 Replies)
Discussion started by: Junaid Subhani
3 Replies
LEARN ABOUT FREEBSD
bestups
BESTUPS(8) NUT Manual BESTUPS(8)NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment
NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also
recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option.
Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not
known.
This driver does not support some older Best/SOLA units.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
nombattvolt=num
Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports
battery.charge values just below 100% even when it's completely charged.
If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good
battery.
The author's Best Fortress 750 uses nombattvolt=27.4.
battvoltmult=num
Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage.
For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this
particular case you can set battvoltmult = 12 in ups.conf(8) to fix this.
ID=string
Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry
commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F
AAA is the three-character identification for the UPS model.
BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9.
CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC.
DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC.
EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts
DC and a decimal point is present.
FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for
700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F.
Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0".
BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return
that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery
runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver.
Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes
back on-line, so you can't tell when it is really recharged.
Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This
leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use
nombattvolt= in ups.conf(8) to fix this.
AUTHOR
Russell Kroll, Jason White
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 BESTUPS(8)