i am writing a bash script.. that produce output some thing like this:
i would like to combine all the entries that having the same but incremental (not sure what is the correct term) first column in condition that the rest of the column are exact match. best way to explain is by the following desire output:
im a beginner in script writing. mostly using bash script to automate my task and in my bash script contain nothing but very useful tool from unix itself like sed awk tail sort uniq column etc...
Last edited by Scott; 10-14-2017 at 10:31 PM..
Reason: Code tags
I am new to Unix and have tried to write a ksh script to do the following without success:
I have several reports in a directory (report1, report2, report3, etc). I would like to combine all of these reports into one file (REPORTS). I would like to append *** End of Report *** to each report so... (2 Replies)
I am trying to get some data from a file and print it on the same line.
I have a script that gets the date/time and calculates a DB query call time and sends to a file. I need to take this file and send it in a xcel like format with multiple data columns.
example output file (fndbq.out)
... (3 Replies)
The following input needs to be manipulated as follows:
INPUT from file or results of command:
============start:
Medium identifier : a45c0213:47eb5485:0aec:0321
Medium label : SQL Disk_11516
Location :
Protected : None ... (2 Replies)
Hi all,
I once knew of a simple unix command to do this, but I can't remember it and I can't find it by searching.
I have two files.
### FILE A ####
A1
A2
A3
A4
A5
### FILE B ####
B1
B2
B3
B4
B5 (2 Replies)
Hi all,
What is the sed command use to combine line?
Example:
Below is an output after extracted from few commands
aaa
bbb
ccc
ddd
eee
fff
ggg
and i would like to combine all the line as shown below,
aaa,bbb,ccc,ddd,eee,fff (5 Replies)
Hi,
I am not very familiar with sed and awk and i have a huge file to process which is impossible to do manually. I want to print out beginning from "Network" until end of line only (excluding the Version). AND. the decription to be all in one line.
File:
Version: 2.0 Network: xxx... (9 Replies)
Hello all,
i am new to linux , and please need your help and suggestion on....
when vi 1.txt :set list, it looks like
$ is displaying the end of line
Filter: vlan1-BUM-1M $
BUM-1M 0 ... (4 Replies)
I am trying to combine lines with these conditions:
1. First line starts with text of "libname VALUE db2 datasrc" where VALUE can be any text.
2. If condition1 is met then continue to combine lines through a line that ends with a semicolon.
3. Ignore case when matching patterns and remove any... (5 Replies)
Discussion started by: Wes Kem
5 Replies
LEARN ABOUT HPUX
machid
machid(1) General Commands Manual machid(1)NAME
machid: hp9000s200, hp9000s300, hp9000s400, hp9000s500, hp9000s700, hp9000s800, hp-mc680x0, hp-pa, pdp11, u370, u3b, u3b10, u3b2, u3b5, vax
- provide truth value about processor type
SYNOPSIS DESCRIPTION
The following commands return a true value (exit code 0) if the a processor type matches the command name. Otherwise a false value (exit
code nonzero) is returned. These commands are commonly used within makefiles and shell procedures to improve portability of applications
(see make(1)).
+-----------+-------------------------++--------+--------------------------+
|Command | True for ||Command | True for |
+-----------+-------------------------++--------+--------------------------+
|hp9000s200 | Series 200 ||pdp11 | PDP-11/45 or PDP-11/70 |
|hp9000s300 | Series 300 ||u3b | 3B20 computer |
|hp9000s400 | Series 400 ||u3b2 | 3B2 computer |
|hp9000s500 | Series 500 ||u3b5 | 3B5 computer |
|hp9000s700 | Series 700 ||u3b10 | 3B10 computer |
|hp9000s800 | Series 800 or 700 ||u370 | IBM System/370 computer |
|hp-mc680x0 | Series 200, 300, or 400 ||vax | VAX-11/750 or VAX-11/780 |
|hp-pa | Series 700 or 800 || | |
+-----------+-------------------------++--------+--------------------------+
EXAMPLES
Given a shell script that must behave differently when run on an HP 9000 Series 700 or 800 system, select the correct code segment to be
executed:
WARNINGS
always returns true on both Series 800 and Series 700 systems. Therefore, when using this command in scripts to determine hardware type,
always use both and in the appropriate sequence to ensure correct results (see
machid(1) will no longer provide support for future machines beyond the Series 800 and Series 700 systems. Decisions should be based on
the hardware and software configuration information returned by getconf(1).
SEE ALSO getconf(1), make(1), sh(1), test(1), true(1).
machid(1)