Sponsored Content
Operating Systems Linux Identify newly attached LUN from NetApp Post 303002306 by fretagi on Tuesday 22nd of August 2017 02:55:21 AM
Old 08-22-2017
Hi

Please can I have help on this?
 

10 More Discussions You Might Find Interesting

1. Solaris

Netapp filer LUN Resize. Commands to run on Solaris afterwards.

Hi, I need to increase a veritas filesystem I have currently mounted on a Solaris 10 server. We can resize the LUN on the NetApp filer no problem. What I need to know is what do I do next on the Solaris 10 server I have so that it will see the increase in size. Do I run 'devfsadm' to... (3 Replies)
Discussion started by: gwhelan
3 Replies

2. Solaris

Can't see Netapp LUN on Solaris using LPFC after reboot.

Hi, I've just edited this post. I found the solution for this. Thanks. (0 Replies)
Discussion started by: gwhelan
0 Replies

3. Red Hat

Redhat 5 can't see my newly added LUN.

hi all, i have added new LUN to Redhat 5. i have already scanned LUN devices and it is confirmed that Kernel sees the newly added LUN's. i have used /proc/partitions and verified that my disks are there. However, i cannot find my disk using fdisk -l command. I am not sure what did i... (2 Replies)
Discussion started by: gisu0602
2 Replies

4. Solaris

new attached lun in solaris 10

hi, what are the steps to detect and configure a new attached lun in Solaris 10. Is there any difference between cfgadm and luxadm command ? rgds, snjksh (5 Replies)
Discussion started by: snjksh
5 Replies

5. Solaris

Can't see Newly created LUN by SAN admin

hello, i am an oracle DBA and trying to scan a newly created LUN of 200 GB on fiber channel by SAN admin.we have solaris 10 and SANtoolkit is installed.i tried following to get the new LUN at my machine. go /opt/Netapp/Santoolkit/bin and then ./sanlun lun show but i see only the existing... (12 Replies)
Discussion started by: janakors
12 Replies

6. Solaris

Solaris- How to scan newly attached NIC's

Hi folks, How can I scan newly attached network interfaces to server without reboot? Is there any command or something to scan without reboot. Thanks (5 Replies)
Discussion started by: snchaudhari2
5 Replies

7. Solaris

Swap space related issues, how to recognise the newly attached disk

hi!:) i got a problem....:wall::wall: i got several disks in my diskarray. I attached new disk to allocate it to the swap space. The problem is : how to recognise the newly attached disk? I've one more requirement -:wall:- i want to run dns service on another port number.how can i do... (2 Replies)
Discussion started by: vamshigvk475
2 Replies

8. AIX

Netapp iscsi lun

Hi, I have aix 6.1 box. I want to configure iscsi luns from netapp storage. I tried in google but not getting proper solution for that. i m not getting the proper iqn name. Please share me the steps to complete this requirements. Thanks in advance. (1 Reply)
Discussion started by: sunnybee
1 Replies

9. Hardware

Formatting a newly created lun

Hi , I have created one new lun in my SAN storage and make it visible to my HP servers , but the fdisk -l output is somehow confusing. Do not know what to do next ---------- fdisk -l /dev/sdo1 Disk /dev/sdo1 (Sun disk label): 64 heads, 32 sectors, 10238 cylinders Units =... (7 Replies)
Discussion started by: mishra.sankar
7 Replies

10. Linux

Mount a newly added LUN on a GNU/Linux distro

Hi I am not familiar with the linux, but I was asked to create a file system on a LUN from the NetApp that was mapped to the linux server. The server is runing: uname -a Linux localhost.localdomain 2.6.18-92.el5 #1 SMP Tue Apr 29 13:16:15 EDT 2008 x86_64 x86_64 x86_64 GNU/Linux and now... (6 Replies)
Discussion started by: fretagi
6 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 12:39 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy