Sponsored Content
Operating Systems Solaris Unable to see controller C1 on Solaris 8 Post 302995948 by DukeNuke2 on Saturday 15th of April 2017 04:54:30 PM
Old 04-15-2017
What does cfgadm -al -o show_FCP_dev c1 show?

I asume your Solaris version is not patched properly. In the beginning cfgadm would not show FCAL devices (luxadm was used for that). You need the "SAN foundation suite" installed and patched to have cfgadm show FCAL devices.

The V880 was one of the first servers that used an internal FCAL loop for the internal harddrives. All the other devices are SCSI and are shown perfectly in cfgadm output. GA date for the V880 was November 2001. So in computer years that thing is a dinosaur Smilie.

Last edited by DukeNuke2; 04-15-2017 at 06:16 PM..
 

10 More Discussions You Might Find Interesting

1. Solaris

Unable to uninstall package in Solaris

I am getting the below mentioned error while trying to unistall a package from a 2.8 Solaris box. Please help.. pkgrm: ERROR: unable to determine current run-state Removal of <PDMgr> failed (internal error). No changes were made to the system. (1 Reply)
Discussion started by: chrisanto_2000
1 Replies

2. Filesystems, Disks and Memory

HD Controller does not Work in Solaris

Hi, I'm attempting to build a raid Z NAS using solaris, but I only have 4 sata ports on my MB, so I bought a Rosewill RC-211 PCIe controller (adds 2 sata II ports). I'm new to solaris, but I understand that to add a new drive, you first run #devfsadm, which puts the files into /dev/dsk. I... (3 Replies)
Discussion started by: ciscocbee
3 Replies

3. Infrastructure Monitoring

unable to shutdown solaris 10

hi folks, i have a snag, when i attempt shutdown of solaris 10 on a sunfire v240 it seems to pause for ages, and goes no further, im busy learning my way around the system so please be patient. /etc(R)-bash-3.00$ init 6 /etc(R)-bash-3.00$ svc.startd: The system is coming down. Please wait.... (7 Replies)
Discussion started by: alienkidmj12
7 Replies

4. Solaris

Unable to login using ssh,telnet onto my solaris machine with solaris 10 installed

Hi, I am unable to login into my terminal hosting Solaris 10 and get the below error message "Server refused to allocate pty ld.so.1: sh: fatal: libc.so.1: open failed: No such file or directory " Is there anyways i can get into my machine and what kind of changes are required to be... (7 Replies)
Discussion started by: sankasu
7 Replies

5. Solaris

unable to use thumbdrive in Solaris 10

hi friends, i had this problem in a Solaris 10 server when i inserted my thumbdrive, i can't find the device file containing usb. what should i do ? (2 Replies)
Discussion started by: Exposure
2 Replies

6. Solaris

unable to login Solaris 10

I have inherited a solaris 10 server. I went to log into it the other day over the console connection, and after sucessfully entering the password, I was booted back to the login prompt with no errors visible. If I enter an incorect password, the console displays 'incorrect password' and kicks... (8 Replies)
Discussion started by: Sol-nova
8 Replies

7. Solaris

Solaris 11 server as Primary Domain Controller

Hi, All of our servers run Solaris (currently 10, but looking to upgrade to 11). In each of our offices we have a server configured as a Primary Domain Controller via Samba to provide naming services to our Windoze users. I would like to continue with that arrangement, but I would also like... (2 Replies)
Discussion started by: wgkorb
2 Replies

8. Solaris

Unable to add printer in Solaris

HI I am unable to add printer in solaris (architecture is SUN and OS is Solaris 10) as I try to print the file it gives following error Failed to contact service for erp-cljCP2025: not-found Need help Regards (7 Replies)
Discussion started by: smazshah
7 Replies

9. Solaris

Unable to reboot Solaris

Hi, we have a sun sparc solaris 10 machine and recently there was a power failure and one of the server domain was down. So today morning i have powered up the domain and it returned me to ok prompt then i have booted the machine with disk from devalias, the system was up as normal and no error... (0 Replies)
Discussion started by: phanidhar6039
0 Replies

10. Solaris

Unable to get Solaris 11 Zone onto the network

Hello, I followed these instructions to create a Solaris 11 zone: http://www.oracle.com/technetwork/articles/servers-storage-admin/o11-092-s11-zones-intro-524494.html And I am unable to ping anything from the Local Zone except for the IP address of the global zone. My global zone has an IP... (6 Replies)
Discussion started by: unblockable
6 Replies
cfgadm_scsi(1M) 					  System Administration Commands					   cfgadm_scsi(1M)

NAME
cfgadm_scsi - SCSI hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -c function ap_id... /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -x hardware_function ap_id... /usr/sbin/cfgadm [-v] [-a] [-s listing_option] [-o hardware_option] [-l [ap_id | ap_type ... ]] /usr/sbin/cfgadm [-v] [-o hardware_option] -t ap_id... /usr/sbin/cfgadm [-v] [-o hardware_option] -h [ap_id...] DESCRIPTION
The SCSI hardware specific library /usr/lib/cfgadm/scsi.so.1 provides the functionality for SCSI hot-plugging through the cfgadm(1M) com- mand. cfgadm operates on attachment points, which are locations in the system where hardware resources can be dynamically reconfigured. Refer to cfgadm(1M) for information regarding attachment points. For SCSI hot-plugging, each SCSI controller is represented by an attachment point in the device tree. In addition, each SCSI device is rep- resented by a dynamic attachment point. Attachment points are named through ap_ids. Two types of ap_ids are defined: logical and physical. The physical ap_id is based on the physical pathname, whereas the logical ap_id is a shorter more user-friendly name. For SCSI con- trollers, the logical ap_id is usually the corresponding disk controller number. For example, a typical logical ap_id would be c0. SCSI devices are named relative to the controller ap_id. Thus if a disk device is attached to controller c0, its ap_id can be: c0::dsk/c0t0d0 where dsk/c0t0d0 identifies the specific device. In general, the device identifier is derived from the corresponding logical link for the device in /dev. For example, a SCSI tape drive logical ap_id could be c0::rmt/0. Here c0 is the logical ap_id for the SCSI controller and rmt/0 is derived from the logical link for the tape drive in /dev/rmt. If an identifier can not be derived from the link in /dev, a unique identifier will be assigned to it. For example, if the tape device has no link in /dev, it can be assigned an ap_id of the form c0::st3 where st3 is a unique internally generated identifier. A simple listing of attachment points in the system will include attachment points at SCSI controllers but not SCSI devices. Use the -a flag to the list option (-l) to list SCSI devices as well. For example: # cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok To list SCSI devices in addition to SCSI controllers: # cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t14d0 disk connected configured unknown c0::dsk/c0t11d0 disk connected configured unknown c0::dsk/c0t8d0 disk connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok Refer to cfgadm(1M) for more information regarding listing attachment points. The receptacle and occupant state for attachment points at the SCSI controller have the following meanings: empty not applicable disconnected bus quiesced (I/O activity on bus is suspended) connected bus active configured one or more devices on the bus is configured unconfigured no device on the bus is configured The corresponding states for individual SCSI devices are: empty not applicable disconnected bus to which the device is attached is quiesced connected bus to which device is attached is active configured device is configured unconfigured device is not configured OPTIONS
cfgadm defines several types of operations besides listing (-l).These operations include testing, (-t), invoking configuration state changes, (-c), invoking hardware specific functions (-x), and obtaining configuration administration help messages (-h). -c function The following generic commands are defined for the SCSI hardware specific library: For SCSI controller attachment points, the following configuration state change operations are supported: connect Unquiesce the SCSI bus. disconnect Quiesce the bus (suspend I/O activity on bus). Incorrect use of this command can cause the system to hang. See NOTES. configure Configure new devices on SCSI bus. unconfigure Unconfigure all devices connected to bus. The following generic commands are defined for SCSI devices: configure configure a specific device unconfigure unconfigure a specific device -f When used with the disconnect command, forces a quiesce of the SCSI bus, if supported by hardware. Incorrect use of this command can cause the system to hang. See NOTES. -h ap_id SCSI specific help can be obtained by using the help option with any SCSI attachment point. -o hardware_option No hardware specific options are currently defined. -s listing_option Attachment points of class scsi can be listed by using the select sub-option. Refer to the cfgadm(1M) man page for additional information. -t ap_id No test commands are available at present. -x hardware_function Some of the following commands can only be used with SCSI controllers and some only with SCSI devices. In the following, controller_ap_id refers to an ap_id for a SCSI controller, for example, c0. device_ap_id refers to an ap_id for a SCSI device, for example: c0::dsk/c0dt3d0. The following hardware specific functions are defined: insert_device controller_ap_id Add a new device to the SCSI controller, controller_ap_id. This command is intended for interactive use only. remove_device device_ap_id Remove device device_ap_id. This command is intended for interactive use only. replace_device device_ap_id Remove device device_ap_id and replace it with another device of the same kind. This command is intended for interactive use only. reset_device device_ap_id Reset device_ap_id. reset_bus controller_ap_id Reset bus controller_ap_id without resetting any devices attached to the bus. reset_all controller_ap_id Reset bus controller_ap_id and all devices on the bus. EXAMPLES
Example 1: Configuring a Disk The following command configures a disk attached to controller c0: # cfgadm -c configure c0::dsk/c0t3d0 Example 2: Unconfiguring a Disk The following command unconfigures a disk attached to controller c0: # cfgadm -c unconfigure c0::dsk/c0t3d0 Example 3: Adding a New Device The following command adds a new device to controller c0: # cfgadm -x insert_device c0 The system responds with the following: Adding device to SCSI HBA: /devices/sbus@1f,0/SUNW,fas@e,8800000 This operation will suspend activity on SCSI bus c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 4: Replacing a Device The following command replaces a device attached to controller c0: # cfgadm -x replace_device c0::dsk/c0t3d0 The system responds with the following: Replacing SCSI device: /devices/sbus@1f,0/SUNW,fas@e,8800000/sd@3,0 This operation will suspend activity on SCSI bus: c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 5: Encountering a Mounted File System While Unconfiguring a Disk The following command illustrates encountering a mounted file system while unconfiguring a disk: # cfgadm -c unconfigure c1::dsk/c1t0d0 The system responds with the following: cfgadm: Component system is busy, try again: failed to offline: /devices/pci@1f,4000/scsi@3,1/sd@1,0 Resource Information ------------------ -------------------------- /dev/dsk/c1t0d0s0 mounted filesystem "/mnt" FILES
/usr/lib/cfgadm/scsi.so.1 hardware specific library for generic SCSI hot-plugging ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), luxadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) NOTES
The disconnect (quiesce) operation is not supported on controllers which control disks containing critical partitions such as root (/), /usr, swap, or /var. The disconnect operation should not be attempted on such controllers. Incorrect usage can result in a system hang and require a reboot. Hotplugging operations are not supported by all SCSI controllers. WARNINGS
The connectors on some SCSI devices do not conform to SCSI hotplug specifications. Performing hotplug operations on such devices can cause damage to the hardware on the SCSI bus. Refer to your hardware manual for additional information. SunOS 5.10 21 Sept 2005 cfgadm_scsi(1M)
All times are GMT -4. The time now is 12:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy