Hello,

Looking for some guidance to changing how an AIX 6.1 server sees its luns. Presently they're connected via 1GB iscsi but I want to change it to 4GB fiber channel. Anyone done this before and if so is it an easy step?

I'm thinking this can be done in this order:
  1. unmount the filesystems
  2. varyoffvg vg
  3. make the changes on the storage system (EMC)
  4. cfgmgr
  5. varyonvg vg
  6. mount the filesystems

I've never done this before so I'm hoping its that simple but IBM is never that simple.

Any help is much appreciated.

Last edited by rbatte1; 03-17-2017 at 12:32 PM.. Reason: Changed textual numbered list to formatted numbered list with LIST=1 tags
 

10 More Discussions You Might Find Interesting

1. AIX

AIX vpath lun

Hi everyone, how can I check if I have LUNs in a server and the LUNīs vpath in AiX? thx (5 Replies)
Discussion started by: jcpetela
5 Replies

2. AIX

AIX not detecting LUN

Hello All, Really hoping someone can help. We have an AIX server connected to a Quantum SDLC sitting in front of an S10K library. The library has 3 logical partitions (two LTO4, one LTO3), so it requires 3 distinct medium changers. The SDLC presents the 3 luns (which are the medium... (1 Reply)
Discussion started by: jwholey
1 Replies

3. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

4. AIX

Mount a SAN LUN which contains clone copy - AIX 6.1

Hello Everyone, Can someone help me to mount a SAN hdisk which contains a clone data copy(san) of the remote server to the another machine. Both servers are running in AIX. Thanks in advance ! Regards, Gowtham.G (3 Replies)
Discussion started by: gowthamakanthan
3 Replies

5. AIX

Increase LUN size in AIX with VIOS and HACMP

Hello! I have this infraestructure: - 1 POWER7 with single VIOS on Site A. - 1 POWER6 with single VIOS on Site B. - 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A. - 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB. - 1 Storage DS4700 on Site A. - 1... (8 Replies)
Discussion started by: enzote
8 Replies

6. Solaris

Mpathadm showing no paths to 1 lun, others luns are fine

Hi, I've noticed that mpathadm states that one of our luns has no active paths: /dev/rdsk/c6t60000970000298700009533031324333d0s2 Total Path Count: 4 Operational Path Count: 4 /dev/rdsk/c6t60000970000298700009533031333037d0s2 ... (3 Replies)
Discussion started by: badoshi
3 Replies

7. AIX

Add new LUN in AIX

Hello all! I have not so much experience with AIX We have test p5 server. On server was deployed VIOS + 3 LPAR + AIX6.1 There is a test HACMP cluster of two nodes, the cluster is identical to production cluster (all clusters and hosts have been configured by specialist of integrator company and... (3 Replies)
Discussion started by: Ravil Khalilov
3 Replies

8. AIX

AIX help -reconnect EMC lun

we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies

9. Solaris

How to avoid seeing various paths to just one LUN?

Hi I have a server running solaris 10 in which the NetAppadmin has just presented one LUN of 200Gb, but when running: bash-3.2# format Searching for disks...done c3t500A09828DE3E799d1: configured with capacity of 199.94GB c3t500A09829DE3E799d1: configured with capacity of 199.94GB ... (5 Replies)
Discussion started by: fretagi
5 Replies

10. Post Here to Contact Site Administrators and Moderators

AIX server do not detect LUN from HP storage

ssssssssssss (0 Replies)
Discussion started by: sampathenjoy
0 Replies
ifc_disable_mgmt_lun(5) 					File Formats Manual					   ifc_disable_mgmt_lun(5)

NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management luns is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters ifc_disable_mgmt_lun(5)