Sponsored Content
Full Discussion: Sun v215 Fan Speed
Operating Systems Solaris Sun v215 Fan Speed Post 302988469 by y33t on Tuesday 27th of December 2016 02:35:52 AM
Old 12-27-2016
Sun v215 Fan Speed

Hi all,

I made some calculations and it seems that fans are working more than they supposed to keep the internals at the specified values. Is there a way to adjust this ?

I have 2 approaches ;

-from ALOM sc|ok prompt
-from Solaris 10

or

-from a HW Switch

I am pretty sure that experienced users can provide some insight on this. The docs are just gone missing.
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

dmidecode, RAM speed = "Current Speed: Unknown"

Hello, I have a Supermicro server with a P4SCI mother board running Debian Sarge 3.1. This is the "dmidecode" output related to RAM info: RAM speed information is incomplete.. "Current Speed: Unknown", is there anyway/soft to get the speed of installed RAM modules? thanks!! Regards :)... (0 Replies)
Discussion started by: Santi
0 Replies

2. Solaris

Sun box's NIC speed setting

Is there a way to check if my Sun box's network interface card is set to 10 or 100 Mbps? Thanks! (1 Reply)
Discussion started by: FredSmith
1 Replies

3. BSD

Fan control

Hi all, Is there any way that I can get some control over th fan in my Evo N400C laptop running OpenBSD 4.0? Right now the fan is running constantly and it woulf be nice if it could be quiet sometime. (1 Reply)
Discussion started by: Timmy66
1 Replies

4. UNIX for Advanced & Expert Users

Unable to connect to Sunfire v215 box via XStart

SUN DataBase Server (Sunfire v215) Machine addresses Server IP:10.8.104.53 Server Mgmt IP:10.8.104.51 Server hostname:memstestdb OS passwords root:********* oracle:********* ALOM (Admin/Management) Machine IP: 10.8.104.51 ALOM account and password: admin:s@vi2005 (Note: at the... (2 Replies)
Discussion started by: jai111
2 Replies

5. Filesystems, Disks and Memory

data from blktrace: read speed V.S. write speed

I analysed disk performance with blktrace and get some data: read: 8,3 4 2141 2.882115217 3342 Q R 195732187 + 32 8,3 4 2142 2.882116411 3342 G R 195732187 + 32 8,3 4 2144 2.882117647 3342 I R 195732187 + 32 8,3 4 2145 ... (1 Reply)
Discussion started by: W.C.C
1 Replies

6. Solaris

Fan failure

would Solaris 10 shutdown automatically if both CPU fans fail? (7 Replies)
Discussion started by: orange47
7 Replies

7. Solaris

Sun Fire V240 server Fan replacement

I have a sun fire v240 server. The output of prtdiag -v shows a failed fan. There are 3 fans for cooling system board. There is 1 fan for each of the powersupply (There are 2 powersupplies) From the below output how do i know which fan is bad and whats its location... (3 Replies)
Discussion started by: Tirmazi
3 Replies

8. Hardware

How to remove fan from cpu fan chassis?

hi all, kindly help in this matter. Can i check anyone has any experience in removing the CPU fan from its chassis? my fan is spoilt and i wish to replace with other type. See picture below.. http://zone11.codemicroinc.netdna-cdn.com/large_1054367.jpg ---------- Post updated at 05:15 PM... (6 Replies)
Discussion started by: lchunleo
6 Replies

9. Solaris

Sun Fire V210 CPU Fan Temp too high?

Hey, I have a V210 with a failed CPU fan. The temperature is currently at 84C and I've been asked to wait a few weeks before replacing as its a production system and it cant be shut down yet. Is it too hot? Do I risk killing the CPU at this temp? Its been like this for a few weeks now... (5 Replies)
Discussion started by: magarvo
5 Replies

10. Solaris

Sun v215 ALOM Reset

Hi all, I got a v215 but the login credentials are unknown. I plug the serial management RS232-RJ45 and get the output on the terminal. I reseted NVRAM and battery but I can't use the default login still. After these operations the output from boot is as such ; ALOM POST 1.0 Status =... (21 Replies)
Discussion started by: y33t
21 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_alom - Fence agent for Sun ALOM DESCRIPTION
fence_alom is an I/O Fencing agent which can be used with ALOM connected machines. fence_alom accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_alom can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. Vendor URL: http://www.sun.com PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: true) -k, --identity-file=<filename> Identity file for ssh -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 5) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: true) identity_file Identity file for ssh inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 5) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_alom (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 02:28 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy