Sponsored Content
Full Discussion: 2540-M2 Firmware
Operating Systems Solaris 2540-M2 Firmware Post 302988062 by callmebob on Tuesday 20th of December 2016 06:22:34 AM
Old 12-20-2016
2540-M2 Firmware

Hi all,
Does anyone know how to upgrade the controller firmware on a storagetek 2540-M2 Array?

Thanks in advance

Martin
 

10 More Discussions You Might Find Interesting

1. Solaris

One StorageTek 6140 vs Two (2) 2540 's?

We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey. Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)? One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies

2. Solaris

fdisk -l doesn't see one 2540 array, can see other arrays though

I can't seem to get my host to see a 2540 array. I have 3 arrays right now. (2) 2540's.. let's call them 2540A and 2540B and (1) 6140. 2540A and the 6140 are configured and mounted on the same linux host. For the life of me, I cannot get the other problem-child 2540B to be recognized by the... (6 Replies)
Discussion started by: buddhavelvet
6 Replies

3. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies

4. Solaris

Storagetek 2540

Hi peeps, Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables. Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies

5. Hardware

Storagetek 2540

Hello all ! I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server. I... (2 Replies)
Discussion started by: acorradi
2 Replies

6. Hardware

StorageTek 2540 battery failed

Hi all, My Sun StorageTek 2540 have redundant batteries, but a battery was failed. # /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru Name FRU Alarm State Status Revision Unique Id -------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies

7. Hardware

Storagetek 2540

Hi Guys and Gals, Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable. Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies

8. Hardware

2540 firmware update

Hi Guys and Gals, does anyone know how to update the firmware on the drives in a storagetek 2540? Thanks in advance Rgrds Martin (0 Replies)
Discussion started by: callmebob
0 Replies

9. Solaris

StorageTek 2540 SAN array

Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun. We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies

10. Solaris

Lost out-of-band communication with 2540 Array

Hello Dears, My server hots cannot contacted my array disk 2540 by using out-of-band Ethernet Cable. The Controller Ethernet port is off , I replace the ethernet cable but not OK I reboot the server and the Array disk 2540 but Not OK. Please somebody know how to solve this issue? ... (1 Reply)
Discussion started by: ghislino
1 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 03:53 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy