Seems like Solaris-11 is not compatible/supported for this software. I have installed as per your downloadable link, but it is generating dump. If this is so, I need not go back and remove both SAS cables and plug them on MB "somewhere" and that will bypass RAID controller.
We used kstat on netra240/440 to check if the link is full duplex. So we do something like:
bash-3.00# kstat -pc net bge:1::/'link_duplex'/ | cut -f2
2
The output 2 indicates the link is full duplex. This kind of check worked all right for Netra 240/440 systems.
However, the nxge... (2 Replies)
I 've 2 different T5220 and both are showing different prompts when i ssh to the console.
1. Shows sc> ALOM
2. Shows -> ILOM
as far as i know the T5220 comes with ILOM , so why i 'm seeing 2 different type of console for same tyep of hardware ?
and i found that we... (6 Replies)
Hi,
SC on one of my T5220 is not responding .. it does not show not let me type anything .. what could be the reason for it ? though when i powercycle the box from sc it shows me the system coming up but after that does not let me login thru sc
sc> console -f
Enter #. to return to ALOM. (2 Replies)
We're just about to migrate a large application from an Enterprise 6900 to a pair of T5220s utilising LDOMs. Does anyone have any experience of LDOMs on this kit and can provide any recommendations or pitfalls to avoid?
I've heard that use of LDOMs can have an impact on I/O speeds as it's all... (9 Replies)
Hi,
We have two T5220 servers in our datacentre
one server is showing 64 processors online
and another showing 32 processors online
two are newly purchased, there is no hardware faults in this server
one server has 64gb memory and it shows 64 processors,
and other having 32gb memory and it... (5 Replies)
I have a new T5220 racked at our remote office and the guys who racked it does not know how to configure the SP on the system .. is there any way i can do it remotely ? (1 Reply)
I'm trying to use a V210 (sun4u) configured as a jumpstart server to flash install a number of T5220's (sunv4).
The Facts:
V210 - Solaris 10 (September 2010 Release / not patched)
T5220's - Archive's created using prior (unknown) version of solaris 10.
Flar -i <archive name> shows the... (6 Replies)
Hi Guys and Gals,
Wondering if anyone could help me, tricky one this.
Got a T5220 with a graphics card. When you power it on, it outputs its output to the screen and you can type commands with the keyboard etc.
But no matter what version of Solaris 10 you use, when you do a boot cdrom... (1 Reply)
Hello guys,
can anyone give me some advice on how to perform
clean installation of Solaris 10 on T5220 ?
I am connected with serial management port on the machine,
i have the ok promt and now i should eject the dvdrom to insert
Solaris dvd into and start the clean install.
So how to do that... (3 Replies)
We have one box T5220 which was assigned 2x100G Luns but i have a strange problem if i use powermt display it only shows me one card but cfgadm, fcinfo commands shows 2 dual port cards as up. What could be the reason for it. I already did a re-configure reboot but that didn't help. Can anyone help... (1 Reply)
Discussion started by: fugitive
1 Replies
LEARN ABOUT DEBIAN
array-info
array-info(1)array-info(1)NAME
array-info - check the status of a HP (Compaq) SmartArray controller
SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h]
DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA
and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con-
troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive.
OPTIONS --device | -d
Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1
--all-drives | -a
Show informations about all drives
--logical drive | -l
Show informations about selected logical drive
--show-ctrl | -c
Show informations about controller
--show-logical | -L
Show informations about logical drives
--show-physical | -p
Show physical device informations
--show-status | -s
Show status of logical drives
--show-all | -A
Show all informations
--version | -V
Show version
-h Show help about options
COPYRIGHT
This manual page was written by Raphael Pinson <<raphink@ubuntu.com>>. Permission is granted to copy, distribute and/or modify this docu-
ment under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation.
2006-12-15 array-info(1)