Sponsored Content
Full Discussion: Cfgmgr Error
Contact Us Post Here to Contact Site Administrators and Moderators Cfgmgr Error Post 302981669 by Don Cragun on Friday 16th of September 2016 05:45:57 PM
Old 09-16-2016
Moderator's Comments:
Mod Comment Using multiple accounts to get around read-only status is not allowed.

Posting technical questions in non-technical forums is not allowed.

This thread is closed.
These 3 Users Gave Thanks to Don Cragun For This Post:
 

10 More Discussions You Might Find Interesting

1. AIX

LPAR and CFGMGR

I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies

2. AIX

cfgmgr and hdisk number allocation

Hi - can anybody tell me what the default behaviour is for cfgmgr when it allocates hdisk numbers to newly discovered disks in the ODM ? I want to add a disk from our FAStT700 SAN disk array and import it on our p-series (AIX 5.2). Problem is we import and export Flashcopy devices fror scripted... (5 Replies)
Discussion started by: fosteria
5 Replies

3. AIX

cfgmgr

Hi All, I remember my old senior mentor in AIX that cfgmgr should not be terminated on your console. Because if it's terminated in the middle, the odm might get corrupted. Is that true for AIX 5.x? Regards, itik (1 Reply)
Discussion started by: itik
1 Replies

4. AIX

cfgmgr: Filesets missing

Hi all, I have a System i server with a couple of AIX LPARs. One of the LPARs owns a dual-channel scsi adapter to which I connect a tape library (IBM TS3100) and a DVD Drive. I had some problems to get the Tape Library detected but finally I got it: rmt0 Available 03-08-01-4,0 IBM 3580... (1 Reply)
Discussion started by: wendelalexis
1 Replies

5. AIX

Dual port NIC, cfgmgr

OS: AIX 6.1 The host has a dual port NIC installed and when I went to run `cfgmgr -v` to configure it I got an error showing device packages are missing from the install: `cfgmgr -v` on 10.15.xx.xxx cfgmgr: 0514-621 WARNING: The following device packages are required for device support but... (3 Replies)
Discussion started by: b1f30
3 Replies

6. AIX

cfgmgr in my aix box

Hi When I run cfgmgr -v in my aix box I get the below error : cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.loopback My oslevel is 6100-06-02-1044 Please assist. Please use and tags when... (3 Replies)
Discussion started by: samsungsamsung
3 Replies

7. UNIX for Dummies Questions & Answers

> 5 ")syntax error: operand expected (error token is " error

im kinda new to shell scripting so i need some help i try to run this script and get the error code > 5 ")syntax error: operand expected (error token is " the code for the script is #!/bin/sh # # script to see if the given value is correct # # Define errors ER_AF=86 # Var is... (4 Replies)
Discussion started by: metal005
4 Replies

8. AIX

cfgmgr: 0514-621 WARNING

Dear all i have a sun SL500 tape library attached to my AIX box while issue the command cfgmgr i have the below issue test>cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.fcp.changer please... (3 Replies)
Discussion started by: thecobra151
3 Replies

9. Solaris

Rpcinfo: can't contact portmapper: RPC: Authentication error; why = Failed (unspecified error)

I have two servers with a fresh install of Solaris 11, and having problems when doing rpcinfo between them. There is no firewall involved, so everything should theoretically be getting through. Does anyone have any ideas? I did a lot of Google searches, and haven't found a working solution yet. ... (2 Replies)
Discussion started by: christr
2 Replies

10. AIX

Time taking for cfgmgr on dual VIO

Hi, From the man page, cfgmgr configures devices and optionally installs device software by running the programs specified in the Configuration Rules object class and it is not dependent on platform . Are there any fundamental differences impacting the speed of cfgmgr on a stand-alone and... (5 Replies)
Discussion started by: Sachin1987
5 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 02:39 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy