Turn up the volume...
Use a beeper extension cable...

All jokes aside: how do you connect to that computer? How do you start the remote job? Are you able to modify that job? How fast needs that notification to be?
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

email notification if job is killed/dies

hi folks, anybody there with suggestions on how to have an email sent to an address (if a certain job (jobA) ever dies. the concern is over the trigerring of sending the email (not the actual sending of the email) 1. is it possible for the job in question, jobA, itself do such a thing... (2 Replies)
Discussion started by: jacob_gs
2 Replies

2. Shell Programming and Scripting

killing unix job after the job process completes

Hi, Thanks in advance. i need to kill a unix background running job after that job process completes. i can kill a job by giving the following unix command kill -9 processid how to kill the job after the current process run gets completed ? Appreciate your valuable help. ... (1 Reply)
Discussion started by: dtazv
1 Replies

3. Solaris

killing a unix job after the job process gets completed

Hi, Thanks in advance. i need to kill a unix background running job after that job process completes. i can kill a job by giving the following unix command kill -9 processid how to kill the job after the current process run gets completed ? Appreciate your valuable help. Thanks... (7 Replies)
Discussion started by: dtazv
7 Replies

4. UNIX for Dummies Questions & Answers

background job finished notification

In my last job someone gave me the command to put in my .profile that let me know when a job I had running in the background finished. It was a word about 5 char long. I can't remember it! (4 Replies)
Discussion started by: nkeller
4 Replies

5. UNIX for Dummies Questions & Answers

How to insert child job under a box job?

I have this box job and it contains only one job under it which is to load a file. I want to insert a "File Watcher", "Copy File" to it? Have no clue how to do that...any help plzzz... (4 Replies)
Discussion started by: xejatt
4 Replies

6. AIX

Cron Job notification email

Hi, I'm fairly new to Aix and am looking for some help on the following. I have setup a cron job under root and want it to send the email once it's run to an external email address. I can get it to send the output in an email to me by using mail on the end of the crontab entry. But I would... (1 Reply)
Discussion started by: elmesy
1 Replies

7. UNIX for Advanced & Expert Users

if up notification

Hello experts, I have a requirement of notifying my application everytime a network interface is brought up. My application supports Various Unix flavours e.g. RHEL, SLES, AIX, Solaris and Mac OS. I know that SLES supports /etc/sysconfig/network/if-up.d hook scripts that run once an interface is... (2 Replies)
Discussion started by: GajendraSharma
2 Replies

8. Shell Programming and Scripting

Script to Start a Job after finding the Old job completed

Hi Experts, I need a script advice to schedule 12 jobs ( SAS Codes execute back ground ). Algorithem: 1. Script checks first job. 2. Finds first job is done; invoke second job. 3. finds second job is done; invoke third job. .. Request you to please assist. (3 Replies)
Discussion started by: Jerald Nathan
3 Replies

9. Shell Programming and Scripting

autosys job configuration for job failure.

We need to configure autosys that when a job fails continously for 3 times, we need to call another job. Is this possible in Autosys, or can anyone advice on the alternative. (2 Replies)
Discussion started by: sangea
2 Replies

10. UNIX for Advanced & Expert Users

Autosys Job: Job did not start

I have submitted an autosys job and force start it. Autosys hit the job 4 times to restart but it did not start and finally I terminate the job. Any idea why the job did not start. Below is the code I executed. 1214 missun0ap /export/home/bzn97r/develop/dswi/jil$ sendevent -E FORCE_STARTJOB... (0 Replies)
Discussion started by: jnrohit2k
0 Replies
SAFENET(8)							    NUT Manual								SAFENET(8)

NAME
safenet - Driver for SafeNet compatible UPS equipment NOTE
This man page only documents the hardware-specific features of the safenet driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver supports UPS equipment which can be controlled via SafeNet v1.0 for Windows (serial interface only). EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file: manufacturer=value Autodetection of this parameter is not possible yet (and it probably never will be). Therefore, this user-defined string accepts any name. The default is unknown. modelname=value Like manufacturer above. The default is unknown. serialnumber=value Like manufacturer above. The default is unknown. ondelay=value Time to wait before switching on the UPS (minutes). Defaults to 1 minute. offdelay=value Time to wait before shutting down the UPS (seconds). Defaults to 30 seconds. UPSCMD
This driver supports some instant commands (see upscmd(8)): test.battery.start Start UPS self test test.battery.stop Cancel UPS self test test.failure.start Start simulated power failure test.failure.stop Cancel simulated power failure beeper.enable Enable the UPS beeper beeper.mute Temporarily mute the UPS beeper beeper.toggle Toggle the UPS beeper shutdown.return Turn off the load and wait for the power to return. Uses the timer defined by offdelay. shutdown.reboot Turn off the load and return. Uses the timers defined by offdelay and ondelay. KNOWN PROBLEMS
If you run the shutdown.return command with mains present, the output may stay on or switch off and not back on again. The shutdown.reboot command will unconditionally switch on the load again (with or without mains present). If the driver is called with the -k option (or through upsdrvctl shutdown) it tries to detect which command should be used in an attempt to stay off until mains is present again or to cycle the output if the power returned in the mean time. This isn't bullet-proof, and you should be prepared that the power will either not be shutdown, or that it doesn't return when the power comes back. AUTHOR
Arjen de Korte <adkorte-guest at alioth.debian.org> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 SAFENET(8)