it's now sadly some time ago I actively worked with these beside some courses, but here we go (I hope the other guys correct me if there is an error in my explanation):
Basically each port will show up as single interface, like a 4 port NIC assigned to a VIOS will show as ent0, ent1, ent2, ent3.
Today you usually want to bind 2 physical adapters together with a main and a backup adapter which ist called an Etherchannel. You can also bundle adapters together (Link Aggregation) for performance reasons, but you can only have 1 backup adapter and that should be, as said, another physical adapter.
So it depends a lot on your layout how many networks you want to have connected to your systems.
Many setups I had to do with looked like this:
You will also want a HASEA (High Available Shared Ethernet Adapter), so that in case of failure of the whole EtherChannel, the 2nd VIOS can take over - but I leave this out for now.
The EtherChannel is built with smitty etherchannel on the VIOS and don't forget to have no IP-address on the adapters you put together. The IP-address will be assigned later on the new generated SEA!
On the HMC you create a virtual Ethernet Adapter with a , that will be the virtual Ethernet Adapter with a Port VLAN ID (PVID, not the Physical Volume Identifier ) and check the box that it will be the adapter with contact to the outside physical LAN.
You also create the other virtual Ethernet Adapters that will be assigned to each LPAR via HMC, but they don't get the check in the box as they don't have a connection to the outside.
The SEA will be created on the VIOS command line by "fusing" the virtual Ethernet Adapter with the checked box for the outside communication together with the EtherChannel Adapter you created formerly out of the 2 physical adapters.
The assignment, which virtual Adapter in an LPAR corresponds to which SEA is solely defined by the PVID they share, in the "painting" above I took PVID 11 as example.
Next to this setup for the ADMIN LAN, you will probably have such a construct for a PROD LAN and a BACKUP LAN (network backup), but I was too lazy to "paint" them next to this
With 4x4 ports per box, you have different options now. If you have a very big load on the NICs, you can either bundle ent0, ent1, ent2, ent3 together in a Link Aggregation, so that they all 4 form up the "main" adapter in the EtherChannel and you get a lot of possible throughput. Though you will have to take a port of another physical adapter as the backup adapter for your Etherchannel. Though what to do with the rest of 3 ports on this physical adapter..?
If you don't need for aggregated ports, then you can setup maybe something like:
Maybe someone else has a better idea how to assign your many ports, but it all depends on what you want/have to achieve.
For SAN, you will have to decide if you go for vSCSI or NPIV.
vSCSI will let you provide LVs, VGs or PVs from the VIOS to the LPARs. The LPAR will see them as normal hdisks.
NPIV is N-Port Virtualization and will virtualize a FC-Adapter which then can be assigned to the differnt LPARs. Doing this will create 2 new WWNs, 1 of these is for LPM (Live Partition Mobility), to which the LUNs from your storage will be zoned as usual.
I personally like NPIV more because the administration of the mappings for LUN/DISK-to-LPAR that comes with vSCSI is much more tideous work to handle instead of the zonings and the NPIV-WWNs assignments to the LPARs. The downside is, that you have to do driver updates on each LPAR where vSCSI will be updated on the involved VIOS.
This as a start and quick overview for your considerations.
The HASEAs, which you want to have for sure too, needs some more details when configuring the SEA, but I assume you will have to make your layout 1st.
Last edited by zaxxon; 08-12-2016 at 03:57 AM..
Reason: additions, corrections and more corrections
These 2 Users Gave Thanks to zaxxon For This Post:
Hi -
I am fairly new with unix. I have a unix box, installed with Solaris 2.8. I can get the box hooked up to the internet, not using DHCP but static IP address behind a Linksys firewall. However, I cannot telnet to the unix box or from within the unix box. If I telnet from a windows... (8 Replies)
When I telnet (ssh) over to my Fedora system, I find the colors horrible. For instance, regular files are white text, which is fine, but directories show up as dark blue which is virtually invisible against the black background). Additionally, when using vi, I find the colors great doing perl... (3 Replies)
In sshd_config it is written:
# The strategy used for options in the default sshd_config shipped with
# OpenSSH is to specify options with their default value where
# possible, but leave them commented. Uncommented options change a
# default value.
So does that mean for the following:
... (2 Replies)
Can anybody provide me with usefull links to get knowledge how VIOS works and how to configure Lpars on it? I am tired and feel lazy to search through IBM redbooks :-) .. so pls help me :p (3 Replies)
Hi ,
when i configure my server with a fixed ip address in dhcpd.conf as below
subnet 172.21.151.0 netmask 255.255.255.0 {
range 172.21.151.66 172.21.151.66;
}
host switch {
hardware ethernet 00:05:30:02:DB:31;
fixed-address 172.21.151.66;
}
when i start dhcpd server , it... (2 Replies)
Solaris 10 on an X86 box - Config runs fine has a couple of items in log (really long log file).
When I try make I get
make: Fatal error in reader: Make.inc, line 84: Unexpected end of line seen
line 84 is
LIBRADIUS_WITH_OPENSSL = 1
any ideas on what to try? (1 Reply)
Hello,
Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2.
What is the common practice - should I isolate my vios... (0 Replies)
Hi,
$ ioslevel
2.2.4.10
I always get these errors when I perform any action using the web interface of IVM / VIOS
Shutdown Partitions Help
You have chosen to shutdown the following partitions. The recommended shutdown method is to use the client operating systems shutdown... (1 Reply)
Hi,
I have two physical interface connected to solaris box.
1. e1000g1
2. e1000g2
I have added these interfaced under a same IPMP group "IPMP1"
After that I have configured a test address for e1000g1 like below
ifconfig e1000g1 addif <ip-address> netmask + broadcast + -failover... (1 Reply)