08-04-2016
Hi,
Install AST graphics driver patch 142373-03(or above).
Please check if you are installed with Xorg server patch 125719-49(and above) on your server. If yes then
Install AST graphics driver patch 142373-03(or above).
Hope you are running with Solaris 10 on Sparc x64, if yes then it will solve the problem.
Else open a service request to Oracle, as we have faced the same issue on our Sparc servers.
Hope this help.
Thanks,
Praveen
10 More Discussions You Might Find Interesting
1. Solaris
Hi all,
This is the first time i am using this forum to clear my doubt.
I am using Sun solaris 9 Operating System, I am stuck up with a problem regarding webmin server.I logged in to webmin as system administrator (root)and then clicked change passwords module. It shows the list of... (1 Reply)
Discussion started by: Kundu
1 Replies
2. Solaris
Hello Guys,
I have just joined this forum & hope that I will find a solution to my question.
I have configured NFS shares on my machine solaris 10 (5.10). Shares have rw access for everyone.
Tried starting NFS server daemon with following command.
svcadm -v enable -t network/nfs/server... (3 Replies)
Discussion started by: say_hi_ravi
3 Replies
3. Solaris
I have a solaris server having oracle and oracle apps running !
When some one attempts to generate a code, they click a link on the web interface which runs an rsh script from a computer called Helpdesk onto my solaris server and what happens is the web interface show an error message saying... (4 Replies)
Discussion started by: SmartestVEGA
4 Replies
4. Solaris
Hi,
Occasionally I am getting the port state in CLOSE_WAIT for long time in the solaris server. I am not sure is it application problem or not. Because we are using port 9009 for Tomcat process in our web application, some time when I start the application, the port 9009 is in CLOSE_WAIT... (2 Replies)
Discussion started by: mgmk.84
2 Replies
5. Solaris
Hi,
While we rebooting solaris server ,the system going to Maintenance mode instead of login console.
even we are not able to run fsck command . Thanks in advanced for help.
log attached FYI
Executing last command: boot
Boot device: /pci@83,4000/FJSV,ulsa@2,1/disk@0,0 File and args:... (3 Replies)
Discussion started by: helplineinc
3 Replies
6. Solaris
Hi All,
I am facing problem while doing FTp to solaris server through Windows XP machine.
showing msg as follows
220 matrix FTP server ready.
User (*.*.*.*:(none)): Sun
331 Password required for Sun.
Password:
530 Login incorrect.
Login failed.
ftp> bye
also while doing vi or... (2 Replies)
Discussion started by: sunray
2 Replies
7. Solaris
I am getting following error during deployment in solaris. when i deploy same war in other machine (non-solaris) it works fine. the stacktrace is
< ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <> <1277738498407> <BEA-149205> <Failed to initialize the... (0 Replies)
Discussion started by: paradesi143
0 Replies
8. Solaris
Dear experts,
i am using solaris 10 OS.I have installed the PCRE(perl comptatible reg expression) and it is located in
/opt/local/share/doc/pcre directory which i got through find command
find / -name pcre -print
/opt/local/share/doc/pcre
this software is pre requisite... (0 Replies)
Discussion started by: muraliinfy04
0 Replies
9. Solaris
Hi everyone,
I am new here and I just want to ask for the expert advice from you guys about the problem/issue I am encountering with network printer defined on a Solaris 10 machine.
I have this printer named 'printerA' which I already added via printmgr utility. As an output, here is the... (4 Replies)
Discussion started by: triptrops
4 Replies
10. Shell Programming and Scripting
Good day all.
I'm trying to rename some files in my home directory with some bizarre results. Basically I need to change the IP address in the filename to the hostname which I ggrep from within the file:
-rw-r--r-- 1 bh694n nrc 5095 May 2 20:03 alarms_999.189.161.146.log... (2 Replies)
Discussion started by: BRH
2 Replies
LEARN ABOUT HPUX
gvid_no_claim_dev
gvid_no_claim_dev(5) File Formats Manual gvid_no_claim_dev(5)
NAME
gvid_no_claim_dev - PCI Vendor/Device ID that the gvid graphics driver will not claim
VALUES
Failsafe
Default
Allowed values
Recommended values
Specific to the device you wish to prevent from claiming.
DESCRIPTION
This tunable specifies the PCI Vendor ID and/or Device ID of a graphics device that the HP graphics driver should not claim.
The graphics driver was designed to be a general purpose driver for all PCI graphics cards. As a result, the driver will attempt to claim
any PCI graphics display device found on the system. This can be a problem for graphics device developers who need their own graphics
driver to claim their own graphics device.
The value of will specify a PCI Vendor ID and/or Device ID of a graphics card that the gvid graphics driver should not claim. It is a 32
bit number, with the upper 16 bits containing the PCI Vendor ID and the lower 16 bits containing the PCI Device ID. Either the Vendor ID
or Device ID can use a wildcard value of
For example, if is set to the value the driver will ignore graphics devices with a PCI Vendor ID of and a Device ID of If is set to the
driver will not claim any graphics cards with a Vendor ID of regardless of the Device ID.
Who Is Expected to Change This Tunable?
Anyone who wishes the graphics driver to ignore a specific graphics device. This will typically be someone writing their own graphics
driver for their own hardware.
Restrictions on Changing
Changes to this tunable take effect at the next reboot.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by HP.
Tunable Kernel Parameters gvid_no_claim_dev(5)