Operating Systems Solaris Luxadm display not showing a LUN as expected Post 302976134 by Peasant on Friday 24th of June 2016 06:54:24 AM
Old 06-24-2016
Please post entire format output for one disk without grep (working and not working)

Multipath enabled devices will have under the number and device name /scsi_vhci/... while other will have hardware path /pci ... or similar.

Are you sure you presented the LUN on both paths ?
Have in installed additional FC cards in the meantime ?

Does :
Code:
mpathadm list lu

for the specified (no working) disk one path or there is no output for that disk ?

Hope that helps.
Best regards
Peasant.
 

9 More Discussions You Might Find Interesting

1. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

2. Solaris

luxadm probe and vxdisk list don't matchup

I have a new SAN (Fujitsu Eternus 2000) and am trying to setup a veritas cluster on it, however veritas does not see all of the vluns I have exposed to the box. The OS does see them though. I have seen a lot of post about this, but it seems they are about people having just the opposite problem... (0 Replies)
Discussion started by: timothy.edwards
0 Replies

3. Solaris

Non-Root mode ... luxadm to show path(s) for Disks

Hi Gurus out there... I am pondering over a situation where I have non-root access (user account), where I am trying to determine paths (including multipaths) on a host. "luxadm display" seems very appropriate, but requires root access. Is there anyway I can get the FC path information? ... (1 Reply)
Discussion started by: verisund
1 Replies

4. Shell Programming and Scripting

Display Error [: : integer expression expected

i have lunix 5.4 i make script to tack the export from database 11g by oracle user the oracle sheel is /bin/bash when run this script display this error ./daily_xport_prod: line 36: the daily_xport_prod script #! /bin/sh # ORACLE_HOME=/u01/appl/oracle/product/11.2.0/db_1 export... (8 Replies)
Discussion started by: m_salah
8 Replies

5. Solaris

SAN/Solaris: luxadm shows NOT CONNECTED

Hi, I have a question regarding HBA configuration. Here are the commands' output: # cfgadm -al | grep fc c1 fc-fabric connected unconfigured unknown c2 fc connected unconfigured unknown c5 ... (11 Replies)
Discussion started by: aixlover
11 Replies

6. Solaris

Mpathadm showing no paths to 1 lun, others luns are fine

Hi, I've noticed that mpathadm states that one of our luns has no active paths: /dev/rdsk/c6t60000970000298700009533031324333d0s2 Total Path Count: 4 Operational Path Count: 4 /dev/rdsk/c6t60000970000298700009533031333037d0s2 ... (3 Replies)
Discussion started by: badoshi
3 Replies

7. Solaris

Luxadm displaying incorrect LUN parameter...

Hello, I have Solaris 10 running on one of rack server with dual port FC card. Each port of FC card is connected to two switches respectively. I have been trying to test multipathing functionality with one of FC Storage. While I have two storage controllers , each connected to the two switches... (0 Replies)
Discussion started by: linuxfreaker
0 Replies

8. Solaris

Issue with luxadm?

Hello, I have Solaris 10 running on one of rack server with dual port FC card. Each port of FC card is connected to two switches respectively. I have been trying to test multipathing functionality with one of FC Storage. While I have two storage controllers , each connected to the two switches... (2 Replies)
Discussion started by: linuxfreaker
2 Replies

9. Solaris

LUn' unmapped from storage still showing on Solaris 10

How can i remove LUN's from solaris 10 those are unmapped from SAN? from storage side i got confirmation that they removed lun. but in my solaris box still it's visible. i tried below. root@globalares2.example.com #luxadm -e offline /dev/rdsk/c2t600D02310007D16C42FF09E24B5B8255d0s2... (7 Replies)
Discussion started by: bentech4u
7 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO
vxdisk(1M), vxprint(1M) VxVM 5.0.31.1 24 Mar 2008 pfto(7)