Thank you very much for your responses from both hicksd8 & DukeNuke2 to my question, and I appreciate you. Your information is very useful to me and now I know how to proceed quickly and correctly.

Last edited by DukeNuke2; 06-12-2016 at 05:10 AM.. Reason: Deleted illegel request.
 

8 More Discussions You Might Find Interesting

1. Solaris

Sun Fire 280R Sun Solaris CRT/Monitor requirements

I am new to Sun. I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor? Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies

2. Solaris

Solaris 9 to Solaris 10 upgrade on Sun Fire 3800

Hello there! I have Sun Fire 3800 with very old Solaris 9 and I need to perform upgrade to concurrent Solaris 10 version, preserving current OS configuration. I supose to make it using Live Upgrade, but according to Solaris Live Upgrade Software: Minimum Patch Requirements page, I need to... (5 Replies)
Discussion started by: Sapfeer
5 Replies

3. UNIX for Dummies Questions & Answers

Disable Serials ports in Sun Fire v490

Hello people from Argentina i said you Hello. I am doing some works from an auditory. They want to disable login prompts on serial ports. Somebody knows how to do that? Thank your time. (1 Reply)
Discussion started by: enkei17
1 Replies

4. Solaris

Sun Fire V490 occasionally downs

I can't find why but I suppose it is because of some hardware failures... I have a Sun Fire V490 with Solaris 10 5/08 which runs Sun Cluster 3.2 and it downs occasionally with a circumstances I can't define... Also I note some strange behavior after server failures: when I ran any diagnostics from... (6 Replies)
Discussion started by: Sapfeer
6 Replies

5. Solaris

Sun Fire V240 server Fan replacement

I have a sun fire v240 server. The output of prtdiag -v shows a failed fan. There are 3 fans for cooling system board. There is 1 fan for each of the powersupply (There are 2 powersupplies) From the below output how do i know which fan is bad and whats its location... (3 Replies)
Discussion started by: Tirmazi
3 Replies

6. Solaris

Need Help, I want to reset password for Sun Fire T2000 Server

============================== ALOM BOOTMON v1.3.1 ALOM Build Release: 001 Reset register: f0000000 EHRS ESRS LLRS SWRS ALOM POST 1.0 Dual Port Memory Test, PASSED. TTY External - Internal Loopback Test TTY External - Internal Loopback Test, PASSED. TTYC - Internal Loopback Test TTYC -... (4 Replies)
Discussion started by: Sameer Naik
4 Replies

7. Solaris

Sun-Fire-V490 Printer Issue After Upgrade of Solaris

Hey Guys I am new here, dont know if any one can assist me with this issue. I have a Sun-Fire-V490 machine that was upgraded to version 9 and patched a few months back. Problem is a few network printers managed by the server is printing an extra page that comes out before and after every print... (0 Replies)
Discussion started by: mprogams
0 Replies

8. Solaris

Solaris 10 1/13 & Sun Fire V490 Server

Hi Solaris/Unix Experts, I've installed Oracle Solaris 10 1/13 on a Sun Fire V490 Server via its external Serial Port using a Cisco Console Cable connected to my Laptop PC running SecureCRT terminal emulation software emulating VT100 Terminal. The Sun Fire V490 server has two on-board... (1 Reply)
Discussion started by: ssabet
1 Replies
ARES_QUERY(3)						     Library Functions Manual						     ARES_QUERY(3)

NAME
ares_query - Initiate a single-question DNS query SYNOPSIS
#include <ares.h> typedef void (*ares_callback)(void *arg, int status, int timeouts, unsigned char *abuf, int alen) void ares_query(ares_channel channel, const char *name, int dnsclass, int type, ares_callback callback, void *arg) DESCRIPTION
The ares_query function initiates a single-question DNS query on the name service channel identified by channel. The parameter name gives the query name as a NUL-terminated C string of period-separated labels optionally ending with a period; periods and backslashes within a label must be escaped with a backslash. The parameters dnsclass and type give the class and type of the query using the values defined in <arpa/nameser.h>. When the query is complete or has failed, the ares library will invoke callback. Completion or failure of the query may happen immediately, or may happen during a later call to ares_process(3) or ares_destroy(3). The callback argument arg is copied from the ares_query argument arg. The callback argument status indicates whether the query succeeded and, if not, how it failed. It may have any of the following values: ARES_SUCCESS The query completed successfully. ARES_ENODATA The query completed but contains no answers. ARES_EFORMERR The query completed but the server claims that the query was malformatted. ARES_ESERVFAIL The query completed but the server claims to have experienced a failure. (This code can only occur if the ARES_FLAG_NOCHECKRESP flag was specified at channel initialization time; otherwise, such responses are ignored at the ares_send(3) level.) ARES_ENOTFOUND The query completed but the queried-for domain name was not found. ARES_ENOTIMP The query completed but the server does not implement the operation requested by the query. (This code can only occur if the ARES_FLAG_NOCHECKRESP flag was specified at channel initialization time; otherwise, such responses are ignored at the ares_send(3) level.) ARES_EREFUSED The query completed but the server refused the query. (This code can only occur if the ARES_FLAG_NOCHECKRESP flag was specified at channel initialization time; otherwise, such responses are ignored at the ares_send(3) level.) ARES_EBADNAME The query name name could not be encoded as a domain name, either because it contained a zero-length label or because it contained a label of more than 63 characters. ARES_ETIMEOUT No name servers responded within the timeout period. ARES_ECONNREFUSED No name servers could be contacted. ARES_ENOMEM Memory was exhausted. ARES_ECANCELLED The query was cancelled. ARES_EDESTRUCTION The name service channel channel is being destroyed; the query will not be completed. The callback argument timeouts reports how many times a query timed out during the execution of the given request. If the query completed (even if there was something wrong with it, as indicated by some of the above error codes), the callback argument abuf points to a result buffer of length alen. If the query did not complete, abuf will be NULL and alen will be 0. SEE ALSO
ares_process(3) AUTHOR
Greg Hudson, MIT Information Systems Copyright 1998 by the Massachusetts Institute of Technology. 24 July 1998 ARES_QUERY(3)
All times are GMT -4. The time now is 04:44 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy