05-14-2016
What is firmware level on Ds4300 ?
Please check compatible OS & multipath with that Firmware on IBM SSIC website.
Sent from my Le X507 using Tapatalk
10 More Discussions You Might Find Interesting
1. Solaris
I just installed IBMsddsun64_........... on my sun server. I untarred it (tar xvf) & I tried to install the paxkage. When I did pkgadd -d ./IBMsdd..... I get a message Error, no packages were found.
Any idea
Thanks, (1 Reply)
Discussion started by: Remi
1 Replies
2. UNIX for Advanced & Expert Users
Hi all,
Sorry if this is in the wrong place but needed to make sure lots of people saw this so that hopefully someone will be able to help.
Basically i've upgraded a test server from 4.3 to 5.3 TL04.
The server has hdisk0 and 1 as rootvg locally but then has another vg setup on our ESS... (1 Reply)
Discussion started by: djdavies
1 Replies
3. Filesystems, Disks and Memory
Hello Unix Admins:
Has any one in this distribution list implemented SVC (SAN Volume Contoller - A solution from IBM) in your environment? If you have, do you have any do's / don'ts? Anything which you like sharing would be really appreciated.
For example, my inputs:
I tried implementing... (1 Reply)
Discussion started by: kdossjojo
1 Replies
4. AIX
Can anyone recommend me some reading material surrounding how AIX handles LUNs:
- with and without MPIO installed
- with and without SDD or SDDPCM installed
Where does lspath sit in all of this (MPIO layer?). Can a system be built with just MPIO software? Is MPIO software even needed?
I guess... (0 Replies)
Discussion started by: apra143
0 Replies
5. Red Hat
I was wondering if there is a way of auto-detecting a new vpath, using IBM's SDD driver, on a Linux platform.
ON AIX it is a simple as running cfgmgr.
Alan (0 Replies)
Discussion started by: alanp
0 Replies
6. AIX
Hi folks.
We want to move a "physical" AIX box to a VIOed LPAR. The physical box is running SDD with disks from a DS8300. I want to be able to reattach those LUNs from the DS8300 to my VIO server which is running SDDPCM and then assigned them back to my AIX LPAR. Any thoughts about this?
I... (1 Reply)
Discussion started by: Stephan
1 Replies
7. AIX
I have sdd driver installed correctly but
when I run the command:
datapath query adapter
No device file found
what does it mean.. it is not using vpath or whats wrong? (2 Replies)
Discussion started by: Vit0_Corleone
2 Replies
8. AIX
We have AIX 6.1 system attached to SAN disks (DS4700 and DS8100) thru SVC.
Initially when the system was I forgot to install sddpcm drivers. and wanted to know how can i go with the installation of the sddpcm drivers.
My understandin going thru the manual ... (3 Replies)
Discussion started by: mk8570
3 Replies
9. AIX
I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO.
On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes
Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies
10. AIX
hi all
we recently upgraded our san switches. after that, i found i got many hdisks showing in lsdev with status "Defined" and "Available". the number of "Defined" is equal to "Available". the time stamp shows all "Available" disks created at our downtime night.
"datapath query device"... (0 Replies)
Discussion started by: rs6000er
0 Replies
LEARN ABOUT MOJAVE
ethcheck
ETHCHECK(8) BSD System Manager's Manual ETHCHECK(8)
NAME
ethcheck -- check the integrity of Broadcom Ethernet devices' firmware.
SYNOPSIS
ethcheck --integrity-check [-b filename]
ethcheck --show-hashes [-b filename]
ethcheck --save -b filename
ethcheck --cleanup -b filename
ethcheck --version
ethcheck --help
DESCRIPTION
Ethcheck is an application-layer tool to check the integrity of Broadcom Ethernet devices' firmware.
The following commands can be used with ethcheck:
--integrity-check attempt to automatically determine which firmware you are running, integrity check against the appropriate file, and report
the check result. It requires root privileges.
--integrity-check -b filename integrity check the firmware image, and report the check result.
--show-hashes print the hashes for the current system's Ethernet devices' firmware to stdout. It requires root privileges.
--show-hashes -b filename print the hashes for the given firmware image to stdout.
--save -b filename save this Ethernet device(s)'s firmware in file. It requires root privileges. File name(s) will begin with specificed
filename and be selected according to device ID(s), machine model name, and firmware's version(s). E.g. filename-eth0-0x14e4-0x1686.nvram.bin
--cleanup -b filename zero any privacy-sensitive data (such as MAC address), enabling the file to be shared for analysis.
--version print out ethcheck version number.
--help display a short help.