Sponsored Content
Operating Systems SCO Old COBOL app move to new server Post 302972356 by jgt on Wednesday 4th of May 2016 10:03:23 AM
Old 05-04-2016
Quote:
When you say a pre-2012 motherboard, what technology should or shouldn't it have? And any specific reason for the SSD?
Disclaimer: I have not used or installed 506 for at least 15 years.
For the most part I have used Intel mother boards. I had no problem installing 600 using DH61DL boards until version 206. At one point in 2012 I had 5 of these boards, some 203,204 and 205. When I tried to install 600 on the 206 version, the screen looks like this.

There is a patch for this, that replaces the boot cd for 600, and just loads a kernel, and starts custom. From there, the operating system is installed using the regular cd. I have not tried this with either 507 or 506.
As far as I know there is not an AHCI driver for 506 so the mother board bios has to support the sata controller in compatible ide mode.
I have been using the Intel XPI9400PT network card, but it is no longer available from Intel. It is available from addoncomputer.com.
Old COBOL app move to new server-jul2015-060jpg

Last edited by jgt; 05-04-2016 at 05:10 PM..
 

7 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

how to move a file from one server to another server using FTP in shell script?

I have a file --> file1.txt i need to copy this file to another server using FTP....the 2 servers are server1 and server2..may i know how to write a script that can do this? thanks in advance! Im a newbie to this... (4 Replies)
Discussion started by: forevercalz
4 Replies

2. Programming

cobol crn programme run on express cobol as .gnt

can i run .crn programme in express cobol which support to .gnt programme .... Plz tell me solution (2 Replies)
Discussion started by: bibi
2 Replies

3. Shell Programming and Scripting

Calling script from RM cobol and returning value to cobol

Is there a way you can return a value from a script that is called from a rm cobol program... 01 WS-COMD-LINE-PGM X(39) value sh ./getUserId.sh 12345" 01 WS-RETURN-SYS-CODE PIC 9(8). CALL "SYSTEM" USING WS-COMD-LINE-PGM GIVING WS-RETURN-SYS-CODE. ... (1 Reply)
Discussion started by: pavanmp
1 Replies

4. UNIX for Dummies Questions & Answers

difference weblogic server/webserver/app server

Hi All, I am getting confused with the terms below. All I know is an application can be installed on a server. But I see the following terms used in a company. All of them are installed on same Unix box. Could you please help me out in layman terms as to what these exactly means. (PS: I don't... (1 Reply)
Discussion started by: tostay2003
1 Replies

5. UNIX for Advanced & Expert Users

Sun java app server

quick question: where can I download sun java application server that will run in java6? or both? I need to install sun java app server and java6. thanks ---------- Post updated at 09:20 AM ---------- Previous update was at 09:12 AM ---------- OS: solaris10 (0 Replies)
Discussion started by: lhareigh890
0 Replies

6. Red Hat

Configure app server to view server files

Hi, We have a OEL6.1 installed on our server. We want developers to view there application logs generated on the server, but doesn't really want to give them access to server machine. Can someone please suggest how can we configure apache/httpd to create a url which will show all files in... (1 Reply)
Discussion started by: shrshah64
1 Replies

7. UNIX and Linux Applications

How to Monitor Tomcat App Server?

Tomcat stops logging intermittently for brief intervals of time like for 5 or 6 secs I wish to monitor if my Tomcat process gets stuck, hung or even shutdown or remains healthy at the time i see the problem of no logging. Can you please let me know how can i monitor Tomcat Application... (10 Replies)
Discussion started by: mohtashims
10 Replies
RP(4)							   BSD Kernel Interfaces Manual 						     RP(4)

NAME
rp -- driver for Comtrol RocketPort Intelligent Serial Port Cards SYNOPSIS
device rp For ISA cards, you must specify the port address in /boot/device.hints: hint.rp.0.at="isa" hint.rp.0.port="0x100" DESCRIPTION
This driver provides a kernel device driver for the RocketPort and RocketPort RA serial boards. These boards provide 8, 16, or 32 high-speed serial ports while requiring only 68 bytes of I/O space for all 8, 16, or 32 ports, and do not require an interrupt channel. This driver supports up to four RocketPort or RocketPort RA boards in one machine simultaneously. If you are using four 32 port RocketPort boards, you can put as many as 128 intelligent serial ports on your system. The rp driver supports the following speeds: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 7200, 14400, 57600, 76800, 115200, and 230400. (You must use termios(4), rather than the old style ioctl interface to use non-traditional speeds.) An open on the rp driver will block until carrier is present, unless O_NONBLOCK or CLOCAL is set. HARDWARE CONFIGURATION
The first RocketPort or RocketPort RA card requires a 68-byte contiguous block of I/O addresses, starting at one of the following: 0x100h, 0x140h, 0x180h, 0x200h, 0x240h, 0x280h, 0x300h, 0x340h, 0x380h. The second, third, and fourth RocketPort cards require only a 64-byte con- tiguous block of I/O addresses, starting at one of the above address ranges. The I/O address range used by any of the RocketPort cards must not conflict with any other cards in the system, including other RocketPort cards. The starting range of the I/O ports used by each card must match with the I/O address specified in /boot/device.hints. Since the first RocketPort uses 68 I/O addresses, if the first card is set to use an I/O block starting at 0x100, it will occupy the I/O ports between 0x100 and 0x143. This means that the second, third, or fourth RocketPort board may not use the block of addresses starting at 0x140, since the first three I/O addresses of that range are used by the first board. This is an important point to keep in mind. If you have two ISA cards, one installed at 0x100 and the second installed at 0x180, then you should add the following to /boot/device.hints: hint.rp.0.at="isa" hint.rp.0.port="0x100" hint.rp.1.at="isa" hint.rp.1.port="0x180" The configuration of the RocketPort cards is done via the set of 8 DIP switches, labeled SW1 on the RocketPort card: +-------------------------------+ | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | +-------+-------+---------------+ | Unused| Card | I/O Port Block| +-------------------------------+ DIP switches 7 and 8 are unused, and must be left on. DIP switches 6 and 5 identify the card number of each RocketPort card. The first card installed in the system must have its DIP switches set as card number one; the second card installed in the system must have its DIP switches set as card number two; and so on. As shipped from the factory, DIP switches 6 and 5 are both on by default, indicating that this is the first card installed on the system: DIP Switches 6 5 =================== On On First Card On Off Second Card Off On Third Card Off Off Fourth Card DIP switches 4, 3, 2, and 1 indicate the I/O address range used by the first RocketPort card. If there are more than one RocketPort cards installed in a system, the second, third and fourth RocketPort cards must also be set to the I/O address range used by the first RocketPort card; all cards must have these DIP switches set identically for proper operation. As shipped from the factory, DIP switch 4 is on, and switches 3, 2, and 1 are off by default, indicating an I/O address range used by the first card which starts at 0x180 and extends to 0x1C3. DIP Switches I/O Address Range 4 3 2 1 Used by the First Card ===================================== On Off On Off 100-143 On Off Off On 140-183 On Off Off Off 180-1C3 Off On On Off 200-243 Off On Off On 240-283 Off On Off Off 280-2C3 Off Off On Off 300-343 Off Off Off On 340-383 Off Off Off Off 380-3C3 FILES
/dev/ttyR[0-4][0-9a-f] AUTHORS
Theodore Ts'o <tytso@mit.edu> This driver was written under contract for Comtrol Corporation. For dealer, distributor and other information regarding Comtrol RocketPort, contact Comtrol Corporation at (800) 926-6876 or send email to <info@comtrol.com>. To report bugs for this driver, please send email to <bug-bsdi-rocketport@comtrol.com>. BUGS
If incoming software flow control is enabled on a 486 or Pentium machine, and the flow control is very heavily exercised, on rare occasions a character will get dropped. This problem does not occur on a 386, and it is not currently known whether the bug is in the rp driver or in the BSD/OS tty layer. BSD
November 15, 1995 BSD
All times are GMT -4. The time now is 12:59 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy