04-22-2016
AIX Hardware Migration w/ HACMP...Advice Needed
Hello Everyone,
Hope you all are doing great!
As you can see by the title on top, we are in the process of migrating alot of our servers from Power5 (physical) to Power8 (Virtual). Now it's turn for servers with HACMP Cluster on it. Let me lay out the environment like:
OLD ENVIRONMENT:
The Primary and secondary nodes resides on a Power5 host. Both are physical servers. The rootvg is on internal disks and the data vg's are on SAN Attached storage. Both primary and secondary nodes are on AIX 7.1 TL3 SP4. For HACMP we have a Active-Passive configuration.
NEW ENVIRONMENT:
Everything is virtualized. We have a Dual VIO setup on the Power8s. The boot disk are coming through a Storage cluster on VIO (vSCSI) and Data disks from SAN (NPIV).
As part of the new environment we are also moving on to the new network i.e. different IP subnet. (old=172.XXX) (new=10.XXX)
The way we have been migrating our previous (non-HA/test/dev) servers is that we clone the mksysb on to the vscsi disk on the new lpar before the day of the cutover and configure the new network on the server. On the day of cutover we bring down apps/DB on the old server (p5) then umount FS, varyoff and export VGs and remove the SAN disks. The storage team unmaps the LUNs and maps them back on the NEW WWPNs on the Power8 (NPIV).
On the new server we configure and import the disks and VGs and mount all FS inclulding NFS. Make DNS changes with the new IP and bring down all apps and DBs.
Now once we bring HACMP into the picture things become a little more complicated, can some of the experts here give me sound advice on how can we make the process as smooth as possible as we are moving on to the new server hardware as well as new network.
Thanks in Advance!
10 More Discussions You Might Find Interesting
1. Linux
i'm a grad student taking a UNIX course and a networks course (i have a background in C++ and JAVA). i'm trying to combine the two classes.
My questions stems from a networks programming homework assignment below:
"Using the operating system and language of your choice, develop a program to... (5 Replies)
Discussion started by: trostycp
5 Replies
2. Solaris
I realise this is an odd request - but I need advice please..
I have two server - in different geographical locations..
The have 2 local 72gb disks which are mirrored. I need to get storage added to increase both to 300gb in total each and this needs to be mirrored in case of failure. The... (2 Replies)
Discussion started by: frustrated1
2 Replies
3. AIX
Hi,
redbook documentation is telling that IY17981 fix is required for aix 4.3.3 to aix 5L migration. But there is no mention about that fix in any ML installation packages.
- My system is ML11 :
oslevel –r
4330-11
- But xlC.rte is on wrong version :
lslpp -L xlC.rte
xlC.rte ... (3 Replies)
Discussion started by: astjen
3 Replies
4. Linux
Evening all,
Im trying to get a script that will:
Select the most 3 recent files in a specific directory
Run a command on them (like chmod)
Ask of you would like to continue
Copy the files to another directory
If a linux guru could help me out, it would be very much appreciated.
Thanks... (2 Replies)
Discussion started by: Wiggins
2 Replies
5. Hardware
Hi all,
I've got an issue with my PC and was wondering what you thought might be the issue.
The problem manifests it'self in two ways (at least I'm assuming it's related).
1. I turn the power on at the wall and press the on button, but nothing happens. I have to wait for several seconds to... (3 Replies)
Discussion started by: DougyC
3 Replies
6. Hardware
If anyone here is successfully running Linux Mint and PC-BSD on two dedicated hard disk drives, (no emulator or partitioning stuff), using Phenom II or Athlon II CPU, I'd like to ask your help to pick hardware! (5 Replies)
Discussion started by: Varsel
5 Replies
7. Solaris
We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies
8. HP-UX
Hi guys,
I'm moving some vPars from BL860c I2 and BL870c I2 using the DRD clone and relocation. In some case, as instance to upgrade to BL870c I2, the ERRATA document reports some additional driver to be added to the image made by the DRD and then recompile the kernel before the move to the... (0 Replies)
Discussion started by: cecco16
0 Replies
9. AIX
I'm New to AIX / VIOS
We're doing a FC switch cutover on an ibm device, connected via SAN.
How do I tell if one path to my remote disk is lost? (aix lvm)
How do I tell when my link is down on my HBA port?
Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies
10. Shell Programming and Scripting
I am working on UNIX AIX to Linux migration.
Does anybody know the good site for doing this?
Thanks for contribution (4 Replies)
Discussion started by: digioleg54
4 Replies