I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order... (1 Reply)
I have a 3510 disk array attached to a T2000 server.
The dmesg command shows disk error as follows and is generated a couple of times during the day
Aug 18 03:35:51 myserver SUNWscsdMonitor: <rctrl6042> Standard General Event, CHL:2 ID:22 Drive NOTICE: Drive Recovered Error - 5F8E1F... (1 Reply)
Hi,
I have the Lacie Big Disk, which is a external hard drive enclosure in a hardware RAID0 array of 2x250GB disks. The RAID controller seems to have died, leaving me with 2 working hard drives but no way to get the data. I tried hooking the drives up to a windows machine and using Raid... (4 Replies)
I have read anecdotes about people installing RAID0 (RAID - Wikipedia, the free encyclopedia) on some of their machines because it gives a performance boost. Because bandwidth on the motherboard is limited, can someone explain exactly why it should be faster? (7 Replies)
So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
HI:
I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers)
Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information.
The way that the servers see the disk array, is like... (1 Reply)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT REDHAT
lvmdiskscan
LVMDISKSCAN(8) System Manager's Manual LVMDISKSCAN(8)NAME
lvmdiskscan - scan for all disks / multiple devices / partitions available
SYNOPSIS
lvmdiskscan [-d|--debug] [-h|--help] [-l|--lvmpartitions] [-v|--verbose]
DESCRIPTION
To give an overview about online peripherals usable to LVM, lvmdiskscan scans all SCSI, (E)IDE disks, multiple, loop and network block
devices in the system and lists them on standard output with name, size and type (text/hex). The size is the real device size, not the size
stored in the VGDA (See pvcreate(8) ) for details.
OPTIONS
-d/--debug
Enables additional debugging output (if compiled with DEBUG).
-h, --help
Print a usage message on standard output and exit successfully.
-l, --lvmpartition
Gives an overview about all LVM system identified partitions only.
-v, --verbose
Gives verbose runtime information about lvmdiskscan's activities.
DIAGNOSTICS
lvmdiskscan returns an exit code of 0, if disks / multiple devices / partitions where found and > 0 for error:
1 no special files found
2 no disks / multiple devices / disk partitions found
95 driver/module not in kernel
96 invalid I/O protocol version
97 error locking logical volume manager
98 invalid lvmtab (run vgscan(8))
99 invalid command line
See alsolvm(8), pvcreate(8), pvdisplay(8), pvscan(8)AUTHOR
Heinz Mauelshagen <Linux-LVM@Sistina.com>