Sponsored Content
Operating Systems AIX AIX - Fibre Adapter and IBM Storage Post 302967088 by agent.kgb on Friday 19th of February 2016 08:30:16 AM
Old 02-19-2016
bakunin,

I have in my testlab several old IBM SAN storages directly connected to several different LPARs, using my own ODM and drivers ;-)
 

9 More Discussions You Might Find Interesting

1. AIX

Fibre channel drivers on RS/6000 aix 5L

Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies

2. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

3. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. AIX

IBM AIX on IBM Eseries & x series server

Hi, I want to know whether IBM AIX can be installed on the IBM e series and x series server hardware? Thanks & Regards Arun (2 Replies)
Discussion started by: Arun.Kakarla
2 Replies

5. AIX

IBM DS8000 storage

Sorry Moderator, I know the topic is not allowed here but I couldnot find any other topics to get help from.. So I am interested if anybody knows software to monitor DS8000 storage performance etc. thanks in advance (1 Reply)
Discussion started by: Vit0_Corleone
1 Replies

6. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

7. AIX

IBM SAN storage -- cache battery

Hello, I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ? My query: Replacing the battery will take 6 days, so in the mean time what are the ways... (1 Reply)
Discussion started by: filosophizer
1 Replies

8. AIX

IBM AIX - SAN Storage DS4300 issue

Hi, This is follow up to the post https://www.unix.com/aix/233361-san-disk-appearing-double-aix.html When I connected Pseries Machine HBA Card ( Dual Port ) directly to the SAN Storage DS4300 , I was able to see Host Port Adapter WWN numbers , although I was getting this message... (2 Replies)
Discussion started by: filosophizer
2 Replies

9. AIX

[ASK] - AIX Fibre Channel behavior

Hello all, Let me introduce about the context and my environment. We have an AIX 6.1 system, it has 4 FC channels / > lsdev -Cc adapter | grep fcs fcs0 Available 23-T1 Virtual Fibre Channel Client Adapter fcs1 Available 23-T1 Virtual Fibre Channel Client Adapter fcs2 Available 23-T1... (14 Replies)
Discussion started by: Phat
14 Replies
norewind_close_disabled(5)					File Formats Manual					norewind_close_disabled(5)

NAME
norewind_close_disabled - determine whether access to tape device special files without the no-rewind-on-close option is allowed VALUES
Default Allowed values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on, the tape driver will fail any open on a tape device special file that does not have the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued accidentally from this system on close, possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters norewind_close_disabled(5)
All times are GMT -4. The time now is 11:28 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy