Sponsored Content
Operating Systems AIX AIX - Fibre Adapter and IBM Storage Post 302967021 by bakunin on Thursday 18th of February 2016 05:00:25 PM
Old 02-18-2016
Even if it is possible it is perhaps not desirable anyway. Notice that the SAN switch is where you do the "zoning" - that is, in short: setting rules about which system gets to see which disks.

If you have exactly one SAN system and exactly one Managed System with one LPAR (where you wouldn't need zoning) the question arises why you would use a SAN instead of a simpler (and perhaps much cheaper) ordinary disk rack.

I hope this helps.

bakunin
This User Gave Thanks to bakunin For This Post:
 

9 More Discussions You Might Find Interesting

1. AIX

Fibre channel drivers on RS/6000 aix 5L

Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies

2. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

3. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. AIX

IBM AIX on IBM Eseries & x series server

Hi, I want to know whether IBM AIX can be installed on the IBM e series and x series server hardware? Thanks & Regards Arun (2 Replies)
Discussion started by: Arun.Kakarla
2 Replies

5. AIX

IBM DS8000 storage

Sorry Moderator, I know the topic is not allowed here but I couldnot find any other topics to get help from.. So I am interested if anybody knows software to monitor DS8000 storage performance etc. thanks in advance (1 Reply)
Discussion started by: Vit0_Corleone
1 Replies

6. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

7. AIX

IBM SAN storage -- cache battery

Hello, I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ? My query: Replacing the battery will take 6 days, so in the mean time what are the ways... (1 Reply)
Discussion started by: filosophizer
1 Replies

8. AIX

IBM AIX - SAN Storage DS4300 issue

Hi, This is follow up to the post https://www.unix.com/aix/233361-san-disk-appearing-double-aix.html When I connected Pseries Machine HBA Card ( Dual Port ) directly to the SAN Storage DS4300 , I was able to see Host Port Adapter WWN numbers , although I was getting this message... (2 Replies)
Discussion started by: filosophizer
2 Replies

9. AIX

[ASK] - AIX Fibre Channel behavior

Hello all, Let me introduce about the context and my environment. We have an AIX 6.1 system, it has 4 FC channels / > lsdev -Cc adapter | grep fcs fcs0 Available 23-T1 Virtual Fibre Channel Client Adapter fcs1 Available 23-T1 Virtual Fibre Channel Client Adapter fcs2 Available 23-T1... (14 Replies)
Discussion started by: Phat
14 Replies
fence_vixel(8)						      System Manager's Manual						    fence_vixel(8)

NAME
fence_vixel - I/O Fencing agent for Vixel FC switches SYNOPSIS
fence_vixel [OPTION]... DESCRIPTION
fence_vixel is an I/O Fencing agent which can be used with Vixel FC switches. It logs into a Vixel switch via telnet and removes the spec- ified port from the zone. Removing the zone access from the port disables the port from being able to access the storage. fence_vixel accepts options on the command line as well as from stdin. fenced sends parameters through stdin when it execs the agent. fence_vixel can be run by itself with command line options which is useful for testing. After a fence operation has taken place the fenced machine can no longer connect to the Vixel FC switch. When the fenced machine is ready to be brought back into the GFS cluster (after reboot) the port on the Vixel FC switch needs to be enabled. In order to do this, log into the Vixel FC switch. Then go to: config->zones->config <port> <comma-separated-list-of-ports-in-the-zone> Then apply Consult the Vixel manual for details Vendor URL: http://www.emulex.com OPTIONS
-a IPaddress IP address of the switch. -h Print out a help message describing available options, then exit. -n port The port number to remove zoning from on the switch. -p password Password for login. -S path Full path to an executable to generate the password for login. -V Print out a version message, then exit. STDIN PARAMETERS
agent = < param > This option is used by fence_node(8) and is ignored by fence_vixel. ipaddr = < hostname | ip > IP address or hostname of the switch. passwd = < param > Password for login. passwd_script = < param > Full path to an executable to generate the password for login. port = < param > The port number to remove zoning from on the switch. SEE ALSO
fence(8), fence_node(8) fence_vixel(8)
All times are GMT -4. The time now is 07:32 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy