In COBOL, a hyphen can be used in a field name and in a specific program some field names would be identical to others except a suffix was added--sometimes a suffix to a suffix was used. For example, assume I am looking for AAA, AAA-BBB, and AAA-BBB-CCC and don't want to look at AAA-BBB-CCC results mixed in with just AAA. My try is to ignore the field if it ends with a final hyphen so I wouldn't see "AAA-".
I have tried
in a script.
The problem was that grep could not find a field if it was on the end of a line.
Is there any way to fix this?
TIA
My file creates an output log after which includes a few sql queries.
I segregate them into warnings and errors and then get a total count.
The errors' and warnings' lines always start with SQL{4} followed by the details of the error.
This is what im doing as o now...
errors=`grep -A 1 -E... (11 Replies)
Hi All,
Please tell me how can I Find a string using grep & print the line above or below that in solaris?
Please share as I am unable to use grep -A or grep -B as it is not working on Solaris. (10 Replies)
Hi all ,
I'm new to unix
I have a checked project , there exists a file called xxx.config .
now my task is to find all the files in the checked out project which references to this xxx.config file.
how do i use grep or find command . (2 Replies)
After I create printer queues in AIX, I have to append a filter file location within that printers custom file. within lets say test_queue.txt I need to find the row that starts with :699 and then I need to append on the end the string /usr/local/bin/k_portrait.sh.
Now I've gotten the sed... (2 Replies)
Hello people!
I would like to create one script following this stage
I have one directory with 100 files
File001
File002
...
File100
(This is the format of content of the 100 files)
2012/03/10 12:56:50:221875936 1292800448912 12345 0x00 0x04 0
then I have one... (0 Replies)
Hi All,
I am reading the host file by ignoring the comments and write it to the other file. I am reading with regular expression for IP address.
grep -E '^{1,3}\.{1,3}\.{1,3}\.{1,3}' $inputFile | awk '{for(i=2;i<=NF;i++)print $1,$i}' > $DR_HOME/OS/temp
After that am reading each host... (4 Replies)
Hi,
I want to read a file line by line and exclude the lines that are beginning with special characters. The below code is working fine except when the line starts with hyphen (-) in the file.
for TEST in `cat $FILE | grep -E -v '#|/+' | awk '{FS=":"}NF > 0{print $1}'`
do
.
.
done
How... (4 Replies)
Need to add a numeric & special char to end of the first line
Existing file:
12-11-16|11 2016 Jan 12:34:55|03:55|
13-10-16|10 2016 Jan 12:34:55|03:55|12-11-16|11 2016 Jan 12:34:55|03:55|
14-10-16|19 2016 Jan 12:34:55|03:55|13-11-16|11 2016 Jan 12:34:55|04:55|
15-10-16|18 2016 Jan... (11 Replies)
Hi,
i need to cat a file after # till the end of the file
usually ill do cat /etc/somthing | grep -A999999 #
but its not that professional
thanks
edit by bakunin: please use CODE-tags (or ICODE-tags) for code and data. Thank you. (9 Replies)
Hello,
I have some code that works more or less. This is called by a make file to adjust some hard-coded definitions in the src code. The script generated some values by looking at some of the src files and then writes those values to specific locations in other files. The awk code is used to... (3 Replies)
Discussion started by: LMHmedchem
3 Replies
LEARN ABOUT X11R4
bestups
BESTUPS(8) NUT Manual BESTUPS(8)NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment
NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also
recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option.
Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not
known.
This driver does not support some older Best/SOLA units.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
nombattvolt=num
Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports
battery.charge values just below 100% even when it's completely charged.
If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good
battery.
The author's Best Fortress 750 uses nombattvolt=27.4.
battvoltmult=num
Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage.
For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this
particular case you can set battvoltmult = 12 in ups.conf(8) to fix this.
ID=string
Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry
commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F
AAA is the three-character identification for the UPS model.
BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9.
CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC.
DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC.
EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts
DC and a decimal point is present.
FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for
700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F.
Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0".
BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return
that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery
runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver.
Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes
back on-line, so you can't tell when it is really recharged.
Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This
leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use
nombattvolt= in ups.conf(8) to fix this.
AUTHOR
Russell Kroll, Jason White
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 BESTUPS(8)