12-08-2015
Usually there needs to be some sort of API for the integration of the OS with the storage device in order for the storage array to know that storage is no longer used. There sometimes can also be space reclamation if devices are zeroed by the OS, it depends on the implementation.
9 More Discussions You Might Find Interesting
1. Linux
Please m new around here! Can anyone take me thru implementing bootp on my thin clients via my central server?
Preciate ur assistance. Thanks folks! (2 Replies)
Discussion started by: chuk_uka
2 Replies
2. AIX
Hi, I was told that 300GB of LUN has been allocated to my server by the SAN group. apart from rootvg i have 2 volume groups(oracle) for which i need to add space as follows:
oradbvg 250GB to be added
oralvg 50GB
what are the steps that i should follow after iam being told that LUN has been... (4 Replies)
Discussion started by: karthikosu
4 Replies
3. Filesystems, Disks and Memory
Am trying to differentiate between the local disks and LUN's presented from SAN onto the server. Have Tried fdisk -l, however I quite cudn't differentiate the local disks from SAN presented LUN's.
Can you pls. let me know the procedure and commands to find this.
OS - RHEL 4
SAN - EMC... (3 Replies)
Discussion started by: Crazy_murli
3 Replies
4. Solaris
I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer.
thanks (4 Replies)
Discussion started by: uuontario
4 Replies
5. Shell Programming and Scripting
Hi
I want to include in my script a test for DB connection with jdbc:thin connection string(not using tnsnames.ora)
For example:... (3 Replies)
Discussion started by: gdan2000
3 Replies
6. Red Hat
Hi,
I have a SAN LUN of 550 GB created as an ext3 partition of the entire lun and need to make the lun and partition larger... 600 GB
# fdisk -l /dev/sdj
Disk /dev/sdj: 590.5 GB, 590558003200 bytes
255 heads, 63 sectors/track, 71797 cylinders
Units = cylinders of 16065 * 512 = 8225280... (3 Replies)
Discussion started by: jamba1
3 Replies
7. Red Hat
Calling all Linux GURU's.
The purpose of this thread is to try an recreate what we already have stood up in my environment, however the steps i am having to produce my own.
I have got multiple applications that dump the data to various LUNs, the LUNs are managed by an Enterprise SAN... (11 Replies)
Discussion started by: jcejka
11 Replies
8. Red Hat
Hi All,
I am new for this blog and this is my first Query on this blog. I would like to dael with graet masters on linux.
Here we go,
After storage people created the LUN, How to add that LUN to Linux server. (Make that LUN visibility on linux server.) ?
How to view the LUN... (5 Replies)
Discussion started by: abhay1983
5 Replies
9. Linux
Hi
I am not familiar with the linux, but I was asked to create a file system on a LUN from the NetApp that was mapped to the linux server.
The server is runing:
uname -a
Linux localhost.localdomain 2.6.18-92.el5 #1 SMP Tue Apr 29 13:16:15 EDT 2008 x86_64 x86_64 x86_64 GNU/Linux
and now... (6 Replies)
Discussion started by: fretagi
6 Replies
LEARN ABOUT HPUX
fcd_disable_mgmt_lun
fcd_disable_mgmt_lun(5) File Formats Manual fcd_disable_mgmt_lun(5)
NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
The default value for this tunable is
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management lun is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard Company.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).
Tunable Kernel Parameters fcd_disable_mgmt_lun(5)