Sponsored Content
Operating Systems AIX Power8 S812L:HMC issue and ... Post 302961850 by bakunin on Friday 4th of December 2015 07:00:33 PM
Old 12-04-2015
Quote:
Originally Posted by lilyn
it has 2 disks on the server. Is there a way to check if the server recognize the disks at boot time or something? (sorry, no clue about IBM servers)
Yes, there is. Use one of the ports labelled "HMC", they are called "Service processor ports". (A service processor is similar to a ILO board.) There you can connect to the systems ASMI (the closest thing to it on a hardware you probably know is the BIOS on a PC). Here is a description how to get there. You will need a network cable and a computer (laptop/notebook/...) with a web browser and a configurable IP interface.

I hope this helps.

bakunin
This User Gave Thanks to bakunin For This Post:
 

10 More Discussions You Might Find Interesting

1. AIX

Hmc

Well i am right now working on an IBM P550 risc server with an HMC connected.. The server has 2 logical partitions (Lpar). both lpar is having Aix 5.3 installed. Now I have a doubt.. is it possible to have Aix in one lpar and windows 2003 in another.. cheers Bala (4 Replies)
Discussion started by: balaji_prk
4 Replies

2. AIX

Hmc

Hello everybody, had a question. Iam having a p650 box here, System Model: IBM,7038-6M2 Machine Serial Number: 1078DCC managed system - 1 which has 2 lpars on it i added memory to the box(made sure that memory added was in proper quads and was verified by a CE) after i rebooted the box, the... (4 Replies)
Discussion started by: karthikosu
4 Replies

3. AIX

CDROM Issue on LPAR HMC VIO

Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR. How can I do it without rebooting the LPARS. POWER6 with HMC LPARS = AIX 6.1 Any info developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ... But... (5 Replies)
Discussion started by: filosophizer
5 Replies

4. AIX

AIX and HMC installation issue

I started the AIX install with a fiber channel disk, and let it run: restricted by GSA ADP Schedule Contract with IBM Corp. . . . . . << End of copyright notice for perfagent.tools >>. . . . ... (2 Replies)
Discussion started by: Gideon1a
2 Replies

5. AIX

HMC Commands

Hello All, Can anybody knows a command, what I can check the processes in the HMC restricted shell? :wall: (1 Reply)
Discussion started by: kalaso
1 Replies

6. AIX

[TIP] Migration to POWER8

Read "Migration to POWER8" article to get prepared for migration to POWER8: link removed, advertisement (0 Replies)
Discussion started by: pave01
0 Replies

7. AIX

New IBM Power8 (S822) and StorWiz V3700 SAN, best practices for production setup/config?

Hello, Got a IBM Power8 box (S822) that I am configuring for replacement of our existing IBM machine. Wanted to touch base with the expert community here to ensure I don't miss anything critical in my setup/config of AIX. Did a fresh AIX 7.1 install on the internal scsi hdisk, mirror'ed... (3 Replies)
Discussion started by: c3rb3rus
3 Replies

8. AIX

StorWize v3700 and Power8 (S822) AIX, configuration best practice for LUNs?

Hello, We have an Power8 System (S822) and a IBM StorWize v3700 SAN. The OS is AIX 7.1. With this hardware from what I read I need to download/install special SDDPCM drivers, so I did (SDDPCM VERSION 2.6.6.0 (devices.sddpcm.71.rte). I carved my volumes in the StorWize and presented to... (3 Replies)
Discussion started by: c3rb3rus
3 Replies

9. AIX

HMC in VmWare NIC sl0 issue.

Hi There, First of all I'm new to *nix world, so bear with me and English is not my native tongue :) Now I'm working on the HMC 7.3.3.0 ServPack:0 base_version:20080402.1 to make it work in VmWare (testing in Workstation) I've got HMC installed and realized that network options in GUI... (8 Replies)
Discussion started by: JKat
8 Replies

10. AIX

IBM Power Linux Cluster Fence device on Power8 Platform

wasn't quite sure which forum to post in. What typical fence device to configure for a Power Linux PaceMaker Cluster running on the Power8 Platform (S822 Model of hardware), or what should be ordered with the S822 for use as a Fence Device? (5 Replies)
Discussion started by: mrmurdock
5 Replies
emsweb(1M)																emsweb(1M)

NAME
emsweb - starts the HP-UX Event Monitoring Service tool (a Web interface) SYNOPSIS
[ ] [ ] DESCRIPTION
The HP-UX Event Monitoring Service tool ( ) is used to monitor resource instances and manages requests created on these instances. The HP-UX Event Monitoring Service tool provides both Web-based and terminal user interface. The Web-based interface is launched through the HP System Management Homepage. Superuser privileges are required to access the HP-UX Event Monitoring Service tool. A user who does not have superuser privileges has read-only access to the requests area in the HP-UX Event Monitoring Service tool and cannot modify requests. An attempt will be made to connect to a Mozilla/Netscape Web browser running on the X server defined by the DISPLAY environment variable. If a running Mozilla/Netscape client is found, it will be used, otherwise a new Mozilla/Netscape session will be initiated. This will only happen if the Mozilla/Netscape process is running in the same system as that referenced by the DISPLAY variable, unless the -F option is used. Note: By default, the HP-UX Event Monitoring Service tool (emsweb) invokes the Mozilla Web browser. If you want to support any other browser (Netscape), set the $BROWSER environment variable as shown below: The terminal user interface is invoked if any of the following conditions are true: o The command is invoked with the option. o The environment variable is not set. The Web-based interface is launched if all the following conditions are true: o The command is invoked with option. o The environment variable is set. o The command is available on the system. If the Web-based interface cannot be launched, invokes the terminal user interface. Options recognizes the following options: Forces a client browser to be used in less secure ways. The option forces the client browser to be used or started, even when the X-traffic between the X-server and the Mozilla browser is not secure. Use this option only when you are sure the network traffic between the host where Mozilla is running and the host in the DISPLAY variable is secure. If cannot start the Web browser, the terminal interface is started. When the HP-UX Event Monitoring Service Web interface is invoked by SAM, the option is used. If a privileged user (root) executes the command with the option, a temporary login bypass key is generated. The bypass key enables the user to access the Web interface without having to provide login information again. When the HP-UX Event Monitoring Service Web interface is invoked by SAM, the option is used. Opens the terminal interface for managing requests created to monitor resource instances regardless of the current setting of the environment variable. You can also start the HP-UX Event Monitoring Service tool using one of the following methods: o Invoke and select the Event Monitoring Service (character mode) functional area to launch the terminal user interface and the Event Monitoring Service (Web-based Interface) to launch the Web-based tool o Invoke the HP-UX Event Monitoring Service tool Web interface by typing the URL in the address bar of your browser, where hostname is the name of the server o Launch the HP-UX Systems Insight Manager on the server and select the Event Monitoring Service tool from the Configure -> HP-UX Configuration menu Online Help After the HP-UX Event Monitoring Service tool is started, the online help provides details on how to use the tool. RETURN VALUES
Upon completion, emsweb returns one of the following values: o 0 Successful o 1 An error occurred AUTHOR
was developed by Hewlett-Packard. SEE ALSO
emscli(1M), resls(1), resdata(1) emsweb(1M)
All times are GMT -4. The time now is 11:23 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy