10-18-2015
the media is not corrupted i used CD and usb floppy and USB flash ,i have the driver and i already downloaded it again but the same error msg,i think the problem is not the device or the media !!
there is any otherway to repair the corupted /etc ?
the RAID configuration is working good i checked it
8 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
I am using SCO Unixware 2.1 & some PC clients are connected, suddenly one message appearslike :
UX:strintercept error: dropping message
this message starts coming repeatedly & agtre some time system hangs.I had to reset the system & now the problem is not there.Please suggest, why this is... (0 Replies)
Discussion started by: paprch
0 Replies
2. UNIX for Dummies Questions & Answers
According to this thread: https://www.unix.com/showthread.php?t=1 one guy says However, I cannot find any sco unixware7 iso download link in their download section (http://wdb1.sco.com/clbk_web/owa/dwn_customer), is it really for free, and if that is true, where can I download it?
Thanks, (2 Replies)
Discussion started by: phalcos
2 Replies
3. SCO
Please help me in troubleshooting my problem in Samba?
I tried to instal Samba 3.0.24 in our SCO UnixWare 7.1.4 but after installing the nmbd daemon is not running.
When i check the syslog from /var/adm, the following error appears:
Sep 30 13:04:22 unixeei nmbd: bind failed on port 137... (0 Replies)
Discussion started by: eric_hing
0 Replies
4. SCO
hi,
anybody can give procedure for how to install oracle 8.0.5 in sco unixware 7.1.4. (0 Replies)
Discussion started by: prakrithi
0 Replies
5. UNIX for Dummies Questions & Answers
Hi All
I P2Vd a Unixware 7.1.4 box with VMWare Vsphere. I try to add a network adapter under Network Configuration Manager and it comes up with the error attached.
I've added a virtual adapter using the "E1000" option. It detects both the AMD PCI NET and E1000 virtual adapters under Network... (8 Replies)
Discussion started by: flashinwrx
8 Replies
6. SCO
We are retiring a Unixware 7.1 server that has custom applications on it. It has Raid 5 and we would like to use the machine for other things. Is there a way we can image/clone to virtual machine file and run that VM within say Virtual PC 2007 or VMware? I am not aware of anything to do this. I... (20 Replies)
Discussion started by: ccd1977
20 Replies
7. SCO
(sorry my English, is really poor).
I have a SCO Unixware 7.1.1 and I need install in ML350 G3. Reading in google and HP web, make a floppy disks for install, but the options that I have is for network or floppy disk.
How install from CD with patch for HP smart array 532 ??
or
How... (5 Replies)
Discussion started by: xplertor
5 Replies
8. SCO
Hi, I'm new to this Unix world and have taken over looking after the I.T side of things at work, which includes the internal ERP system which runs on a UNIX SCO platform.
My initial worry is what state this is in as its been on site over 20 years.
What would be the first things to check on... (13 Replies)
Discussion started by: Mick_Dundee
13 Replies
LEARN ABOUT OPENSOLARIS
volcheck
volcheck(1) User Commands volcheck(1)
NAME
volcheck - checks for media in a drive and by default checks all floppy media
SYNOPSIS
volcheck [-v] [-i secs] [-t secs] pathname
DESCRIPTION
The volcheck utility tells volume management to look at each dev/pathname in sequence and determine if new media has been inserted in the
drive.
The default action is to volcheck all checkable media managed by volume management.
OPTIONS
The following options are supported:
-i secs Set the frequency of device checking to secs seconds. The default is 2 seconds. The minimum frequency is 1 second.
-t secs Check the named device(s) for the next secs seconds. The maximum number of seconds allowed is 28800, which is 8 hours. The fre-
quency of checking is specified by -i. There is no default total time.
-v Verbose.
OPERANDS
The following operands are supported:
pathname The path name of a media device.
EXAMPLES
Example 1 A sample of the volcheck command.
The following example
example% volcheck -v /dev/diskette
/dev/diskette has media
asks volume management to examine the floppy drive for new media.
The following example
example% volcheck -i 2 -t 600 /dev/diskette1 &
asks volume management if there is a floppy in the floppy drive every 2 seconds for 600 seconds (10 minutes).
FILES
/dev/volctl volume management control port
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWvolu |
+-----------------------------+-----------------------------+
SEE ALSO
eject(1), rmmount(1M), attributes(5)
WARNINGS
Due to a hardware limitation in many floppy drives, the act of checking for media causes mechanical action in the floppy drive. Continu-
ous polling of the floppy drive will cause the drive to wear out. It is recommended that polling the drive only be performed during periods
of high use.
SunOS 5.11 28 Feb 2007 volcheck(1)