Do someone know how to delete entry(some lines)
in file "wtmpx" that command "last" use it.
this file is binary so I cannot edit directy.
=========================
#last
root pts/1 noc Fri Mar 3 22:04 still logged in
root pts/1 noc Fri Mar 3 22:01 - 22:02 ... (4 Replies)
Hi,
we are running solaris 9 on V280R. Due to power failure, one disk's label and lost its details like drive type etc.
Disk details:
<SUN72G cyl 14087 alt 2 hd 24 sec 424>
single partition on slice 6 with UFS.
The below i see when i run "format" command
.....
.....
4.... (1 Reply)
Hello group,
How can I separate "named daemon" messages to the other file instead of /var/adm/messages. I still want all other daemons log the messages to /var/adm/messages.
i.e.
named => /var/adm/named.message
other daemons => /var/adm/messages.
I searched unix.com, and google but I still... (5 Replies)
Hi guys,
I am still kinda new to Linux.
Script template I found on the net and adapted for our environment:
#!/bin/sh
#set -x
ADMIN="admin@mydomain.com"
ALERT=10
df -H | grep -vE '^Filesystem|tmpfs|cdrom' | awk '{ print $5 " " $1 }' | while read output;
do
#echo $output
... (2 Replies)
Hi,
I want to update managed system firmware using HMC.
The easiest way to me is to download firmware directly to HMC hard disk. Question:
Where shoud I put downloaded firmware in HMC hard disk ? - selection says "Hard disk" - no path no anything.
thanks
Vilius M. (0 Replies)
HP rp5450 (L2000)
running HP-UX 11.11B
Using DLT 7000 and DLT 4000 tape drives for nightly full backups
Backup jobs created by SAM
DLT 7000 cron entry is as follows:
00 2 * * 1-6 /usr/sam/lbin/br_backup DLT FULL Y /dev/rmt/0m /var/sam/graphLCAa17036 root Y 1 N > /var/sam/SAM_br_msgs 2>&1... (1 Reply)
Below is the error being repeated on my Solaris 9 Sun-Fire-V890 machine.
SAN team confirmed as everything is fine from their end. I did google and found that some people say its a known Oracle bug when you have Oracle 10G installed on your system but I kind of disagree with them. Please see below... (2 Replies)
Hi All,
I am a RH Linux admin that recently started working at a company with a number of SUN Servers so it's been an interesting transition.
Considering the last person left with very little documentation left behind so I have been picking up most issues half complete, or troubleshot.
... (7 Replies)
AVAILABLE DISK SELECTIONS:
0. c2t500000E01D2DDCE0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g500000e01d2ddce0
1. c2t500000E01D2DED70d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g500000e01d2ded70
2.... (12 Replies)
Hi just want to ask if anyone has encounter this error?
bash-3.2# echo | format
Searching for disks...Mar 28 14:03:31 server1 scsi: WARNING: /pci@340/pci@1/pci@0/pci@7/SUNW,qlc@0,1/fp@0,0/ssd@w5006016408607763,0 (ssd3):
Mar 28 14:03:31 server1 drive offline
Mar 28 14:03:31 server1 scsi:... (1 Reply)
Discussion started by: gob23g
1 Replies
LEARN ABOUT CENTOS
fp
fp(7d) Devices fp(7d)NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)