Old 09-12-2015
It depends on whether your SAN controller supports SCSI3 reservation irrespective of whether you have SCSI3 disks in the array. There may be a manufacturer's firmware upgrade.

You didn't answer my question as to what make/model the SAN is?

(Do you have two userid's on this forum? I started a dialogue with OP 'sb200' but now being answered by 'amity'.)
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

The difference between SCSI & IDE Hard disks.

Hello agian ! What is the difference between SCSI and IDE hard disks ? I have Intel PC and when i check i have Generic IDE TYPE DISK0 is IDE hard disk is ok for Solrais ? or should i buy the SCSI hard disk ? Thanks Abid Malik (3 Replies)
Discussion started by: abidmalik
3 Replies

2. AIX

SCSI Disks

Hi Is it possible to install in p5 and pSeries SCSI Disks from SUN on DELL? Will they work? Regards, Pit (0 Replies)
Discussion started by: piooooter
0 Replies

3. Solaris

Reclaiming EMC disks after losing paths

First time writer....take it easy on me. I had a situation where I lost all paths to EMC disk. There was a failure on the EMC frame. After that was repaired, my server had a difficult time reclaiming all disks and veritas had marked the disks as failed. Veritas was confused. What are some of... (3 Replies)
Discussion started by: Sowser
3 Replies

4. Linux

Modifying Linux in WesternDigital net disks

Hi, I am installing perl and rsnapshot on the OS of a Western Digital MyBook disk. To install perl the ./Configure command tells me that both 'tr' and 'split' are missing. I don't find them on the net. Where can I download them? Thanks. Charles. (2 Replies)
Discussion started by: mosndup
2 Replies

5. Solaris

Sun cluster and Veritas cluster question.

Yesterday my customer told me to expect a vcs upgrade to happen in the future. He also plans to stop using HDS and move to EMC. Am thinking how to migrate to sun cluster setup instead. My plan as follows leave the existing vcs intact as a fallback plan. Then install and build suncluster on... (5 Replies)
Discussion started by: sparcguy
5 Replies

6. Solaris

Sun cluster 4.0 - zone cluster failover doubt

Hello experts - I am planning to install a Sun cluster 4.0 zone cluster fail-over. few basic doubts. (1) Where should i install the cluster s/w binaries ?. ( global zone or the container zone where i am planning to install the zone fail-over) (2) Or should i perform the installation on... (0 Replies)
Discussion started by: NVA
0 Replies

7. Solaris

Unknown Disks "offline or reservation conflict"

Hi All, I am a RH Linux admin that recently started working at a company with a number of SUN Servers so it's been an interesting transition. Considering the last person left with very little documentation left behind so I have been picking up most issues half complete, or troubleshot. ... (7 Replies)
Discussion started by: MobileGSP
7 Replies

8. HP-UX

HP-UX check SCSI reservation

Hi guys, I need some help to better understand how to determine if a disk have persistent SCSI reservation. I know that we should use the "Persisten Reservation Utility" but we are not allowed to run that tool. Since we have the output from some grab utility and specifically we have the... (0 Replies)
Discussion started by: cecco16
0 Replies
st_ats_enable(5)						File Formats Manual						  st_ats_enable(5)

NAME
st_ats_enable - determine whether to reserve a tape device on open VALUES
Default Allowed values Recommended values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the stape or estape driver whether it needs to reserve a tape device on open and subsequently release it on close. When this tunable is on, the stape or estape driver will attempt to reserve any tape device on open. The driver has a few tape devices flagged as suitable devices for this functionality including: DLT 8000, DLT 7000, STK 9840, HP Ultrium, and others. DDS drives are not flagged for this functionality. The tunable allows the safe sharing of tape devices in multinode configurations like MC/ServiceGuard's Advanced Tape Sharing. The auto- matic reserve and release protects the tape device from being accessed from multiple nodes, which would corrupt a backup. If the reserve portion of the stape or estape driver's open routine fails, a status of is returned. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately and are used during the next open or close. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in an MC/ServiceGuard's Advanced Tape Sharing configuration or the user wants the stape or estape driver to use automatic reserve and release on open and close for multinode manageability. What Are the Side Effects of Turning the Tunable On? A reserve is sent to the tape device by the stape or estape driver on open and a release is sent on close. No other initiator or HBA will be able to access the tape device while it is opened on another initiator or HBA. When Should the Tunable Be Turned Off? This tunable should be turned off for any SAN tape sharing solution configuration other than ATS. Most multinode backup applications (for example, Omniback) manage device reservation themselves, and any interference by the stape or estape driver may produce problems. This tunable should also be turned off for any multiplatform SAN configuration to keep tape access across platforms more uniform. What Are the Side Effects of Turning the Tunable Off? Unauthorized access from another initiator might interfere with any current tape operation. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_ats_enable(5)
All times are GMT -4. The time now is 11:26 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy