Hi,
I am trying to setup redhat native cluster 5, i installed all the required rpms and issued the command service cman start (cman is the cluster manager)
this gives me output...
#service cman start
Starting cluster:
Loading modules... done
Mounting configfs... done
... (0 Replies)
Hello;
I have 2 node Redhat Cluster (RHEL4 U4 and Cluster Suite) I'm using mc_data fiber channel switch for fencing
when I want to fence manually using
fence_mcdata -a x.x.x. -l xxx -p xxxx -n 5 -o disable
following messages appears
fencing node "test1"
agent "fence_mcdata" reports:... (0 Replies)
hello,
During the cluster installation, we are required to enter a cluster name. When this name is used?
I have a shared disk between those 2 nodes. To test NFS failover, what should I do?
PS: I am using VCS 5
thanks (5 Replies)
Hi all
in my server all nfs dependices are online but nfs client is offline
root@BIWAPP1 # svcs -a|grep nfs
disabled Sep_05 svc:/network/nfs/server:default
online Sep_05 svc:/network/nfs/rquota:default
online Sep_05 svc:/network/nfs/mapid:default
online ... (9 Replies)
Hi
i installed samba-client-3.0.23c-2 on Redhat Server but cat not start
#service smb start. it gives error
unrecognized smb
I checked
samba-common-3.0.23c-2
# rpm -qa |grep smb
pam_smb-1.1.7-7.2.1
# rpm -qa |grep samba
samba3-client-3.2.15-40.el5
Could someone help please?
... (1 Reply)
Hi Friends,
I am trying to configure redhat high availability cluster on rhel5 32bit.
As i am not having the RHN subscription, I have to intsall all the cluster suite manually. I am not aware what all are the rpms needs to be installed. Please let me know about the rpms needs to be installed.... (3 Replies)
hi all ,
I'm trying for the Red-hat cluster setup with the ' Enable shared storage support'. But hang up with a error that
"Packages of set "Clustered Storage" are not present in any available repository". I made this setup by installing the rpm manually..I ve attached the rpm list and error... (0 Replies)
Hello Experts,
Please help me with the exact steps on configuring two node cluster on RHEL 6.2,
I failed to configure the simplest cluster by below steps,
1- install RHEL 6.2 64-bit on both nodes
2- add to hosts file of each server ( 1 IP in local NW and another in IP private NW).
x.x.x.x ... (1 Reply)
:b::b:Hello Expert,
I have a query regarding redhat cluster configuration file (/etc/cluster/cluster.conf).
Is there any process to change the location of the configuration file of the cluster. Is there any step in ricci process..
If yes then please explain me how the cluster node will... (0 Replies)
Discussion started by: Pradipta Kumar
0 Replies
LEARN ABOUT CENTOS
rgmanager
clusvcmgrd(8) Red Hat Cluster Suite clusvcmgrd(8)NAME
rgmanager - Resource Group (Cluster Service) Manager Daemon
DESCRIPTION
rgmanager handles management of user-defined cluster services (also known as resource groups). This includes handling of user requests
including service start, service disable, service relocate, and service restart. The service manager daemon also handles restarting and
relocating services in the event of failures.
HOW IT WORKS
The service manager is spawned by an init script after the cluster infrastructure has been started and only functions when the cluster is
quorate and locks are working.
During initialization, the service manager runs scripts which ensure that all services are clear to be started. After that, it determines
which services need to be started and starts them.
When an event is received, members which are no longer online have their services taken away from them. The event should only occur in the
case that the member has been fenced whenever fencing is available.
When a cluster member determines that it is no longer in the cluster quorum, the service manager stops all services and waits for a new
quorum to form.
COMMAND LINE OPTIONS -f Run in the foreground (do not fork).
-d Enable debug-level logging.
-w Disable internal process monitoring (for debugging).
-N Do not perform stop-before-start. Combined with the -Z flag to clusvcadm, this can be used to allow rgmanager to be upgraded with-
out stopping a given user service or set of services.
SEE ALSO clusvcadm(8)
Jan 2005 clusvcmgrd(8)