Operating Systems HP-UX Cstm and gsp conflict on power status Post 302953704 by port43 on Monday 31st of August 2015 12:20:06 PM
Old 08-31-2015
Sorry I left that out; you are correct, it is a very old HP-UX B.11.11 U 9000/800
 

7 More Discussions You Might Find Interesting

1. HP-UX

How to use CSTM on HP-Ux 11i V2

Hi, Newbie here......I am an new guy on HP-Ux... may i ask all the the guru's and who has eperienced here to enlightened me on how to use the CSTM command. My goal is to view the current HW installed on the Server. Thanks in advance. (1 Reply)
Discussion started by: renobal
1 Replies

2. Red Hat

power supply status in sysreport

Hello guys: I'm a beginner in this exciting world of open spource and linux. I'm working as a support engineer and a customer send back to me a sysreport from his system running redhat 4. the customer has a power supply failed in his server and to see it and justify the replacement I required a... (0 Replies)
Discussion started by: amani
0 Replies

3. HP-UX

Conflict between df -k and du -sk...again

Hi, I know this has been discussed a number of time but i could not get the exact answer. So need help again. Issue: The two command for same file system shows different size. du -sk shows toatl size is 12780685 KB while df -k 45289229 used allocated Kb /oxt/mantran/bin $ du -sk... (8 Replies)
Discussion started by: malaya_17
8 Replies

4. Solaris

Solaris 9 IP conflict

Hi Gurus I am in a strange situation. I have a SUN sparc server . The server was having an IP say X..... (this IP X is now being used by another server)..... I have just installed fresh solaris 9 OS on the same server and given new IP say Y. I also configured probe based IPMP with ce0 and... (2 Replies)
Discussion started by: ningy
2 Replies

5. HP-UX

echo "selall;info;wait;infolog" | /usr/sbin/cstm problem

Hello, On a HP-UX 10.20 server I've executed something similar to this command: # echo 'selall;info;wait;infolog;view;done' | /usr/sbin/cstm But it returns sometype of "argument list too long" error. I suppose there is a way to fix it by using xargs but I can't figure it out. Any... (7 Replies)
Discussion started by: asanchez
7 Replies

6. AIX

Finding Power Supply Status

Hi, As in Management Modules of IBM it is possible to find out wheather out of dual powersupply , if one goes down. is it possible to find out in HMC to find out if one power supply goes down of P Series server? if server is remotely HOw to find out if one power supply of server is down?... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

7. Shell Programming and Scripting

Conflict with the operator in IF

I am using a script like this source=$1 if ; then echo "got it" else echo "lost it" fi But the script is giving th error like script.ksh: ==: unknown test operator Can i know , is the syntax iam using is correct or suggest me a good way. ... (3 Replies)
Discussion started by: nani1984
3 Replies
machid(1)						      General Commands Manual							 machid(1)

NAME
machid: hp9000s200, hp9000s300, hp9000s400, hp9000s500, hp9000s700, hp9000s800, hp-mc680x0, hp-pa, pdp11, u370, u3b, u3b10, u3b2, u3b5, vax - provide truth value about processor type SYNOPSIS
DESCRIPTION
The following commands return a true value (exit code 0) if the a processor type matches the command name. Otherwise a false value (exit code nonzero) is returned. These commands are commonly used within makefiles and shell procedures to improve portability of applications (see make(1)). +-----------+-------------------------++--------+--------------------------+ |Command | True for ||Command | True for | +-----------+-------------------------++--------+--------------------------+ |hp9000s200 | Series 200 ||pdp11 | PDP-11/45 or PDP-11/70 | |hp9000s300 | Series 300 ||u3b | 3B20 computer | |hp9000s400 | Series 400 ||u3b2 | 3B2 computer | |hp9000s500 | Series 500 ||u3b5 | 3B5 computer | |hp9000s700 | Series 700 ||u3b10 | 3B10 computer | |hp9000s800 | Series 800 or 700 ||u370 | IBM System/370 computer | |hp-mc680x0 | Series 200, 300, or 400 ||vax | VAX-11/750 or VAX-11/780 | |hp-pa | Series 700 or 800 || | | +-----------+-------------------------++--------+--------------------------+ EXAMPLES
Given a shell script that must behave differently when run on an HP 9000 Series 700 or 800 system, select the correct code segment to be executed: WARNINGS
always returns true on both Series 800 and Series 700 systems. Therefore, when using this command in scripts to determine hardware type, always use both and in the appropriate sequence to ensure correct results (see machid(1) will no longer provide support for future machines beyond the Series 800 and Series 700 systems. Decisions should be based on the hardware and software configuration information returned by getconf(1). SEE ALSO
getconf(1), make(1), sh(1), test(1), true(1). machid(1)