08-04-2015
interesting... i don't think it's the cleaning crew in this instance, but we might need to check the lab. perhaps something new was plugged into the same wall outlet or power bar. thanks for the info.
10 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
I am loging into a SunOS 5.8 box for the first time.
I do not see a .profile file in the home directory. Also on the command line when I type a backspace to correct my typing I get a ^H character. Where and how can I fix this?
Thanks in advance (5 Replies)
Discussion started by: jxh461
5 Replies
2. UNIX for Advanced & Expert Users
I have compiled binary file using "cc" on SunOS 5.8 and the same binary file i have copied to SunOS 5.9 and it is giving me core dump error.I want to know whether migration of compiled code from lower version to higer version created this problem. how can i solve this problem.I am pasting the core... (1 Reply)
Discussion started by: Arvind Maurya
1 Replies
3. Solaris
Hi,
I Hope you can help me with my problem.
I need to have an installation CD of this version.
Is there any site you can recommend that I can download
an image of this OS?
Thanks and God Bless!!! (6 Replies)
Discussion started by: mr_balodoy
6 Replies
4. Solaris
Hey all,
I've got my hands on 10 SunOS 5.6 SPARCStation 20 machines and I'm looking to get them up and running. They're all in various states of disrepair but I've got them all to a state where the hardware is working and the machine will at least attempt to boot.
I've only used Solaris as a... (1 Reply)
Discussion started by: kevpatts
1 Replies
5. Solaris
Hi,
I am bulding a path to open files like this \path\values\file.xxx This path is opened in an IE browser window and opens the file/document I am trying to see. I mean it opens a pdf document or it promps you to "save" or "open" the specific file (if it's a .xml, .doc, .html).
I was using... (1 Reply)
Discussion started by: hcibl_javok
1 Replies
6. Solaris
Hi,
I called Sun and they said they no longer sell SunOS 5.6. I desperately need a CD-ROM of the install CD to perform maintenance work on a server.
Does anyone know where to get one or know someone who can make me a copy? (2 Replies)
Discussion started by: mojoman
2 Replies
7. UNIX for Dummies Questions & Answers
I have Oracle 9i R2 on AIX 5.2. My Database is running in shared server mode (MTS).
Sometimes when I shutdown the database it shutsdown cleanly in 4-5 mints and sometimes it takes good 15-20 minutes and then I get some ora-600 errors and only way to shutdown is by opening another session and... (7 Replies)
Discussion started by: aixhp
7 Replies
8. Ubuntu
Hi
I am new to expect. Please if any one can help on my issue its really appreciable. here is my issue:
I want expect script for random passwords and random commands generation.
please can anyone help me?
Many Thanks in advance (0 Replies)
Discussion started by: vanid
0 Replies
9. Shell Programming and Scripting
Need to use dd to generate a large file from a sample file of random data. This is because I don't have /dev/urandom.
I create a named pipe then:
dd if=mynamed.fifo do=myfile.fifo bs=1024 count=1024
but when I cat a file to the fifo that's 1024 random bytes:
cat randomfile.txt >... (7 Replies)
Discussion started by: Devyn
7 Replies
10. Solaris
Hi,
I've this Oracle database version:
Connected to:
Oracle Database 11g Enterprise Edition Release 11.2.0.4.0 - 64bit Production
Oracle is install in a SunOS DBSERVER1 5.11 11.2 sun4v sparc sun4v cluster (Not RAC environment)
DBSERVER1 is node active and DBSERVER2 is node inactive
... (4 Replies)
Discussion started by: db_senior
4 Replies
CLONE(8) NUT Manual CLONE(8)
NAME
clone - UPS driver clone
NOTE
This man page only documents the specific features of the clone driver. For information about the core driver, see nutupsdrv(8).
DESCRIPTION
This driver, which sits on top of another driver socket, allows users to group clients to a particular outlet of a device and deal with
this output as if it was a normal UPS.
EXTRA ARGUMENTS
This driver supports the following settings:
load.off=command
Recommended. Set the command on the "real" UPS driver that will be used to switch off the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.on=command
Recommended. Set the command on the "real" UPS driver that will be used to switch on the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.status=value
Recommended. Set the variable on the "real" UPS driver that will be used to indicate the outlet status (i.e. on/off). If not specified,
the clone driver will attempt to keep track of the outlet status, but this is less reliable.
offdelay=num
Set the timer (in seconds) before the outlet is turned off after the shutdown condition (OB LB) for this outlet is met or a command to
shutdown was issued. Defaults to 120 seconds.
ondelay=num
Set the timer (in seconds) for the outlet to switch on in case the power returns after the oulet has been switched off. Defaults to 30
seconds.
mincharge=value
Set the remaining battery level when the clone UPS switches to LB (percent).
minruntime=value
Set the remaining battery runtime when the clone UPS switches to LB (seconds).
IMPLEMENTATION
The port specification in the ups.conf(5) reference the driver socket that the "real" UPS driver is using. For example:
[realups]
driver = usbhid-ups
port = auto
[clone-outlet-1]
driver = clone
port = usbhid-ups-realups
load.on = outlet.1.load.on
load.off = outlet.1.load.off
load.status = outlet.1.status
[...]
IMPORTANT
Unlike a real UPS, you should not configure a upsmon master for this driver. When a upsmon master sees the OB LB flags and tells the upsd
server it is OK to initiate the shutdown sequence, the server will latch the FSD status and it will not be possible to restart the systems
connected without restarting the upsd server.
This will be a problem if the power returns after the clone UPS initiated the shutdown sequence on it's outlet, but returns before the real
UPS begins shutting down. The solution is in the clone driver, that will insert the FSD flag if needed without the help of a upsmon master.
CAVEATS
The clone UPS will follow the status on the real UPS driver. You can only make the clone UPS shutdown earlier than the real UPS driver, not
later. If the real UPS driver initiates a shutdown, the clone UPS driver will immediately follow.
Be aware that the commands to shutdown/restart an outlet on the real UPS drivers are not affected, so if you tell the real UPS driver to
shutdown the outlet of the clone UPS driver, your clients will lose power without warning.
AUTHOR
Arjen de Korte <adkorte-guest@alioth.debian.org>
SEE ALSO
upscmd(1), upsrw(1), ups.conf(5), nutupsdrv(8)
Internet Resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 CLONE(8)