Hello Experts,

I need your inputs to figure out the issue I faced post applying Linux patch.

Question:
As a part of change implementation UNIX team applied patches and upgraded OS from version SuSE Linux 11.2.3 to 11.3.6. Post upgrade we could bring up Tomcat successfully; however realized Tomcat SSL has stopped working.

We reviewed Tomcat logs and found that APR (Apache Portable Runtime) libraries got installed and which affect our application functionality:

=== Tomcat Log Snippet ===
Code:
 Jun 4, 2015 8:24:47 AM org.apache.catalina.core.AprLifecycleListener init
 INFO: Loaded APR based Apache Tomcat Native library 1.1.30 using APR version 1.3.3.
 Jun 4, 2015 8:24:47 AM org.apache.catalina.core.AprLifecycleListener init
 INFO: APR capabilities: IPv6 [true], sendfile [true], accept filters [false], random [true].
 Jun 4, 2015 8:24:48 AM org.apache.catalina.core.AprLifecycleListener initializeSSL
 INFO: OpenSSL successfully initialized (OpenSSL 0.9.8h 28 May 2008)
 Jun 4, 2015 8:24:49 AM org.apache.coyote.AbstractProtocol init
 INFO: Initializing ProtocolHandler ["http-apr-8443"]
 Jun 4, 2015 8:24:49 AM org.apache.coyote.AbstractProtocol init
 SEVERE: Failed to initialize end point associated with ProtocolHandler ["http-apr-8443"]
 java.lang.Exception: Connector attribute SSLCertificateFile must be defined when using SSL with APR

====================

Because of business criticality, we rolled-back the installed OS patch, and everything started working as expected.

Could you please advise on, does below mentioned patch install as such libraries? If yes, can we exclude it during installation? (Custom Install).

Environment Details:
  • Server OS version before upgrade: SuSE Linux Platform 11.2.3
  • Server OS version after upgrade: SuSE Linux Platform 11.3.6
  • Tomcat Version: Tomcat 7

Could someone help in identifying issue please?

Regards,
Mahesh

Last edited by Don Cragun; 06-11-2015 at 05:42 PM.. Reason: Remove dozens of COLOR and FONT tags; add CODE tags.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Need Patch Installation Date

Can someone tell me how to get the installation date of a patch? I've done a showrev which I assume tells me if the patch cluster has been installed. It shows...SunOS 5.8 Generic 108528-23 June 2003. I'm assuming June 2003 is the patch release date. Is that right? How can I determine the... (1 Reply)
Discussion started by: kiloflash
1 Replies

2. Post Here to Contact Site Administrators and Moderators

Patch Installation

I am having trouble installing some HPUX patches on my 11.00. I am a novice at this so bear with me. I do not understand how to install depots. Now I'm trying to patch my system so I can get the Oracle client installed. Oracle says I need these two patches: PHSS_21950, QPK_11.00.64 I go to:... (0 Replies)
Discussion started by: RAFA
0 Replies

3. HP-UX

Patch Installation Problem

HI: Thanks for your help Im follow the steps describe on the link http://docs.hp.com/en/B2355-90772/ch06s01.html and have a diffetrent types of error messages and warning messages describes below: on the step two sh: PH* not found on step three *session started for user "root@test"... (0 Replies)
Discussion started by: RAFA
0 Replies

4. HP-UX

Patch Installation Problems

Hi people: I am having trouble installing some HPUX patches on my 11.00. I am a novice :confused: at this so bear with me. I do not understand how to install depots. Now I'm trying to patch my system so I can get the Oracle client installed. Oracle says I need these two patches:... (5 Replies)
Discussion started by: RAFA
5 Replies

5. Solaris

patch installation

Hey hi all, I just recently encountered these question regarding patch installation, the scenario is like these that i have three patches a,b,c and each of them require a server reboot.And I don't have to reboot the server three times..i can reboot it only once.. so what should i do ? Mine... (1 Reply)
Discussion started by: sahil_shine
1 Replies

6. Solaris

Patch Installation on Solaris10

Hi All, I am new to Solaris. I have to install some latest patches on my SPARC Machine running Solaris 10. I have installed the required patches. Please guide me through the rest of the process. Please include even minute details so that I don't face any problems while doing this activity. ... (12 Replies)
Discussion started by: kamaldeep1986
12 Replies

7. Red Hat

Patch Installation

Dear All, I have some 6 RedHat Servers ( 5.4 ) tikanga connected to the Intranet. Some are Database Servers and application servers. For the past 1.5 years , we have not installed any patches.. Is there any way to find out , whether these systems needs patches and where to... (5 Replies)
Discussion started by: jegaraman
5 Replies

8. Solaris

Patch installation

Can any one let me know the complete steps to install patch on a production server like Sun Fire V440. (7 Replies)
Discussion started by: chetansingh23
7 Replies

9. Solaris

OS Patch Installation

Hello, I'm very new to this forum and solaris - I have solaris 5.10 installed on my machine (x86) and when I did a prerequisite check for Oracle Database 11g R2, it was showing the following patches are missing - OS Patch:137104-02 OS Patch:120754-06 OS Patch:119961-05 OS Patch:119964-14... (3 Replies)
Discussion started by: dsreedharan
3 Replies

10. Linux

Patch Installation

Am new to Linux and this forum From where can I download sysstatx86_64 and numactl-devel patches ? Thanks! :b: (1 Reply)
Discussion started by: dsreedharan
1 Replies
pprosvc(1M)                                               System Administration Commands                                               pprosvc(1M)

NAME
pprosvc - automation service program for Patch Manager SYNOPSIS
/usr/sbin/pprosvc [-c config-name] [-d [-p patch-id [,patch-id...]]] [-h] [-i [-n] [-p patch-id [,patch-id...]]] [-l] DESCRIPTION
Note - This command is deprecated. Use the smpatch analyze, smpatch download, and smpatch update commands instead. See the smpatch(1M) man page. Use the pprosvc command to analyze a system to determine the list of appropriate patches, download the patches, and apply them. This com- mand invokes patch operations in response to a user request or at a scheduled time. You must run this command as superuser. The pprosvc command enables you to do the following: o Analyze the host system for appropriate patches based on an established configuration o Generate the list of appropriate patches o Download the patches to your host system from the Sun patch server o Apply the patches based on a patch policy Use the pprosvc -i command to analyze a system, download the appropriate patches, and apply them. If analysis determines that patches are needed, the pprosvc command downloads them and applies them. Specify other options to automate a subset of the patch management tasks. If you specify the -d option, your system is analyzed and the appropriate patches are downloaded to your system. If you specify the -l option, your system is analyzed and the appropriate patches are listed. The list of patches that is generated by the analysis is based on all of the available patches from the Sun patch server. No explicit information about your host system or its network configuration is transmitted to Sun. Only a request for the Sun patch set is transmitted. The patch set is scanned for patches that are appropriate for this host system, the results are displayed, and those patches are optionally downloaded. The -d, -i, and -l options are mutually exclusive. Use the -p option to specify the patches on which to operate. You can use the -p option with the -d and -i options. OPTIONS
The following options are supported: -c config-name Uses an alternate configuration for the current patch operation. Use the pprosetup command to create new configura- tions. A configuration named recommended is included. For more information, see ``Specifying Alternate Configurations'' in the pprosetup(1M) man page. Note - This feature is not supported by the smpatch command. -d Downloads the patches that are appropriate for this host system. The patches are downloaded to the designated down- load directory. This option generates a list of appropriate patches, as does the -l option. However, instead of just displaying the list of patches, the -d option displays and downloads the patches from the Sun patch server. The patches are down- loaded using a secure connection, and all patches are authenticated using digital signature technology. Only patches that are signed with a Sun digital signature are stored in your download directory. Note - Specifying this option is equivalent to running the smpatch download command. -h Displays information about the command-line options. -i Applies the patches based on the patch policy. This option analyzes your system to generate a list of appropriate patches. If analysis determines that patches are needed, the patches are downloaded and applied. If no patches are permitted to be applied in automatic mode (by running pprosetup -p none), this option is identical to specifying the -d option. If only standard patches are permitted to be applied in automatic mode (by running pprosetup -p standard), all standard patches are applied. Note - Specifying this option is equivalent to running the smpatch update command. -l Generates a list of the patches that are appropriate for this host system. Note - Specifying this option is equivalent to running the smpatch analyze command. -n Runs pprosvc in automatic mode. The command that the cron job specifies is pprosvc -i -n. To schedule patch opera- tions to run in automatic mode, see the pprosetup(1M) man page. In automatic mode, the patch administrator (specified by the -a option) receives email notifications that describe the patches you downloaded and applied, and any error events that occurred. Do not use this option on the command line. Standard patches do not require any special actions on the part of the user. Such patches can be applied by using the patchadd command (see the patchadd(1M) man page) and do not need the host system to reboot for the patch to take effect. All nonstandard patches are moved to the sequester directory if you use the -n option to run in automatic mode. If you run in manual mode, however, nonstandard patches that have properties that match the policy specified by ppros- etup -i are applied. The rest of the nonstandard patches are moved to the sequester directory. You can apply patches from this directory at a later time. Patches, whether standard or nonstandard, that depend on sequestered patches are not applied under any circumstances. Such patches are placed in the sequester directory. For any patch that is placed in the sequester directory, refer to the patch's README file to determine how to apply it to your system. Note - This feature is not supported by the smpatch command. -p [patch-id[,patch-id,.Designates the specific patches on which to operate. Use this option with the -d option or the -i option. The list of patch IDs must be separated by commas. The specified patches are adjusted to use the current versions based on the patch baseline. Patches that are required by the specified patches are added to the complete list of patches to be applied. Note - Specifying this option is equivalent to specifying the -i option to the smpatch analyze, smpatch download, and smpatch update commands. EXAMPLES
Example 1: Applying Specific Patches in Manual Mode # pprosvc -i -p 102893-01,106895-09,106527-05 Applies patches 102893-01, 106895-09, and 106527-05 to the local system in manual mode. Example 2: Analyzing a System and Downloading Appropriate Patches # pprosvc -i Performs an analysis of the current system and downloads the appropriate patches based on all the patches from the Sun patch server. The resulting list of patches can be very long. Example 3: Applying Patches From the Recommended Configuration # pprosvc -c recommended -i Uses the recommended configuration to perform an analysis of the current system and downloads the appropriate patches. Standard patches and those needed from the recommended configuration are applied to the system based on the established patch policy. For information about set- ting the patch policy for manual mode, see the description of the -i option on the pprosetup(1M) man page. ATTRIBUTES
See the attributes(5) man page for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpprou | +-----------------------------+-----------------------------+ |Interface Stability |Obsolete | +-----------------------------+-----------------------------+ SEE ALSO
patchadd(1M), patchrm(1M), pprosetup(1M), smc(1M), smpatch(1M), attributes(5) SunOS 5.10 7 May 2004 pprosvc(1M)
All times are GMT -4. The time now is 07:47 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy