Operating Systems HP-UX SAN Migration question Post 302946512 by Peasant on Wednesday 10th of June 2015 12:05:33 AM
Old 06-10-2015
Is the HPUX in question v2 or v3 ?

If the answer is v3, the operation can be online, since on v3, every lun has a WWID.
Just do it port by port, rescan and check paths after each, should not be any issues.

If you want to do it offline, do a vgexport preview (to a file not actual export) of all volume groups on the system using SAN disks (just to be safe do it anyway in each scenario) and deactivate the volume group.

Since the VG info is actually written on disks, even if everything changes (disk names etc.) you will be able to import the volume group using a file you created earlier. There are also other methods (vgscan), but this one is most trivial.

Commands you will require are
scsimgr -> to check lunmap and paths before and after.
ioscan -> to rescan after port change.

This assumes you are using hpux native multipath, not other multipath solutions.
 

10 More Discussions You Might Find Interesting

1. HP-UX

SAN migration

Hi, I'm going to be involved in a migration of SAN islands to one big SAN. I've not worked with SANs before and I'm not sure how to approach this. I suspect the disk devices on the HP servers are going to change, when the EVA's and servers are plugged into this new Cisco 9509 switch. Any... (0 Replies)
Discussion started by: Hils
0 Replies

2. Solaris

Veritas Storage Question (Data Migration)

Using Solaris 10 with Veritas Storage Foundation running. I want to copy all contents from DISKA LUN1 to DISKB LUN2. What would be the command syntax to do this? (0 Replies)
Discussion started by: soupbone38
0 Replies

3. Solaris

Question regarding Zone Migration

I have a general question regarding Zone Migration. I have an older system that is currently running a zone configured with ProFTPD & SSL. If I want to migrate or clone that zone to another (much newer) system, will I still have to setup & configure ProFTPD & SSL on the new system? (3 Replies)
Discussion started by: em23
3 Replies

4. Red Hat

SAN/LVM question

Hey everyone. I am working on designing a logging solution for a deployment we have going out in a few months. Right now we have a single storage head end, connected via fibre to a SAN. Basically the plan is to create a number of smaller LUNs on the SAN, and then use LVM2 to handle concatenating... (5 Replies)
Discussion started by: msarro
5 Replies

5. HP-UX

SAN Migration of HP-UX hosts

Hello gurus, I am a SAN Admin - not very familiar with the HPUX administration - so need help with the steps in regards to the migration I need to do at my client place. Environment: Migrating from CX4 to VMAX - using OR/Hot Pull. Here are the steps I have put together - HPUX gurus please... (5 Replies)
Discussion started by: jps460
5 Replies

6. Solaris

Need Help On Solaris Cluster Steps For San Migration

I am going to do a SAN Array migration and need the sequence of steps required on the Solaris cluster before moving the old array luns to new array luns. Here are the steps and I need info on the bold points:( I might even be wrong on the sequence of steps please correct me if I am wrong) 1.... (0 Replies)
Discussion started by: sunshinedeepu
0 Replies

7. AIX

SAN Migration

Hi all, We are migrating our SAN storage from HSV360 to 3PAR. The system runs aix 6.1 version with HACMP. Please let me know what are requirements from OS side and how are the data copied to the new disks. (10 Replies)
Discussion started by: ElizabethPJ
10 Replies

8. Red Hat

Volume group not activated at boot after SAN migration

I have an IBM blade running RHEL 5.4 server, connected to two Hitachi SANs using common fibre cards & Brocade switches. It has two volume groups made from old SAN LUNs. The old SAN needs to be retired so we allocated LUNs from the new SAN, discovered the LUNs as multipath disks (4 paths) and grew... (4 Replies)
Discussion started by: rbatte1
4 Replies

9. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

10. Solaris

How to identify if disk is attached to SAN and assist in migration.?

I am working on VM host and collecting data to identify the type of storage attached to the server which will be migrated to VNX. it has one ldom created on it luxadm probe output --- No Network Array enclosures found in /dev/es Found Fibre Channel device(s): Node... (7 Replies)
Discussion started by: kpatel786
7 Replies
vgexport(1M)															      vgexport(1M)

NAME
vgexport - export an LVM volume group and its associated logical volumes SYNOPSIS
mapfile] outfile] vg_name mapfile vg_name DESCRIPTION
Using the format of the first command line of the above, the command can be used to remove a volume group from the system. The volume group will be removed without modifying the logical volume information found on the physical volumes. The volume group identified by vg_name is removed from the or file, and the associated device files including the vg_name directory and file are removed from the system. The volume group information and data is untouched on the physical volume. These disks can be imported to another system with the command (see vgimport(1M)). Scan Option Using the format of the second command line of the above, the command generates a mapfile that can be copied to other systems that are part of a high availability cluster (use the option if you do not want to remove the volume group from the system the command is being run from) and the command (see vgimport(1M)) can be used to recreate the volume group. See also vgchange(1M). The mapfile contains a description of the volume group and its associated logical volume(s) (if any). The logical volume information found on the physical volumes is not modi- fied. Options and Arguments recognizes the following options and arguments: vg_name The path name of the volume group. By default, a file named is created in the current directory. This file contains a description of the volume group and its associated logical volume(s) (if any). Use this option to specify a different name for the file, mapfile. This file can be used as input to (see vgimport(1M)). When used with the option, the volume group specified in the mapfile can be shared with other systems in the high availability cluster. Preview the actions to be taken but do not update the or file or remove the devices file. This option is best used in conjunction with the option. Print verbose messages including the names of the physical volumes associated with this volume group. Scan option. When the option is specified, then the options must also be specified. A mapfile is created that can be used to cre- ate volume group entries on other systems in the high availability cluster (with the command). Write the current set of pv_paths for the volume group to the outfile. The outfile may then be used as the infile for the option. If used together with the option the volume group is not exported but the list of pv_paths is still written to the outfile. This may be useful to derive a list of pv_paths for the volume group or to use on another system which is sharing the volume group and which has an identical configuration. EXTERNAL INFLUENCES
Environment Variables determines the language in which messages are displayed. If is not specified or is null, it defaults to "C" (see lang(5)). If any internationalization variable contains an invalid setting, all internationalization variables default to "C" (see environ(5)). EXAMPLES
Export the volume group into mapfile The volume group will be removed from the exporting system. Export the volume group and write the disk names into the file Create a mapfile to be copied to other systems in a high availability cluster to build the volume group information for the volume group, Note that the volume group is not removed from the exporting system. The importing systems will create the volume group with the command using the and options. SEE ALSO
vgimport(1M), vgscan(1M). vgexport(1M)